HRMS System Check for Intact Protein Quantification
Applications | 2019 | WatersInstrumentation
LC/TOF, LC/HRMS, LC/MS, LC/MS/MS
IndustriesProteomics
ManufacturerWaters
Key wordsintact, check, hrms, protein, system, quantification, tof, application, mqc, hqc, lqc, note, setup, subunit, performance, concentration, conc, expected, lockspray, continuum, enkephalin, mrm, metrics, fwhm, measured, good, min, bsa, response, ftn, bioanalysis, accuracy, lock, test, instrument, suitability, showing, document, leading, performing, undertaking, cder, width, standard, robustness, base, plus, reproducible, uplc, acquity
Similar PDF
TANDEM QUADRUPOLE MS FOR THE QUANTIFICATION OF MONOCLONAL ANTIBODY SUBUNIT LIGHT CHAINS IN PLASMA
2019|Waters|Posters
TANDEM QUADRUPOLE MS FOR THE QUANTIFICATION OF MONOCLONAL ANTIBODY SUBUNIT LIGHT CHAINS IN PLASMA Caitlin M. Dunning, Mary E. Lame, and Mark D. Wrona Waters Corporation, Milford, MA, USA INTRODUCTION CHROMATOGRAPHY MASS SPECTROMETRY 5 µg/mL Adalimumab - 10µL - Rep…
Key words
adalimumab, adalimumabcetuximab, cetuximablloq, lloqcet, cetstatistics, statisticsadm, admlight, lightbioresolve, bioresolvechains, chainstandem, tandemquantification, quantificationbiotherapeutics, biotherapeuticsfragment, fragmentconserved, conservedmab
Automated Protein Modification Characterization of the Intact and Subunit NIST Monoclonal Antibody Reference Standard with Waters UNIFI Scientific Information System
2017|Waters|Applications
[ APPLICATION NOTE ] Automated Protein Modification Characterization of the Intact and Subunit NIST Monoclonal Antibody Reference Standard with Waters UNIFI Scientific Information System Nilini Ranbaduge, Henry Shion, and Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS ■■…
Key words
subunit, subunitintact, intactunifi, unifivion, vionmodification, modificationnist, nistqtof, qtofims, imsmass, massmonoclonal, monoclonalantibody, antibodyprotein, proteincharacterization, characterizationmab, mabautomated
Triple Quadrupole Mass Spectrometry (Xevo TQ-XS) for the Quantification of Monoclonal Antibody Light Chains in Plasma
2019|Waters|Applications
[ APPLICATION NOTE ] Triple Quadrupole Mass Spectrometry (Xevo TQ-XS) for the Quantification of Monoclonal Antibody Light Chains in Plasma Caitlin M. Dunning, Mary Lame, and Mark Wrona Waters Corporation, Milford, MA, USA APPLICATION BENEFITS ■ ■ Fast, reproducible, and…
Key words
chains, chainslight, lightquantification, quantificationadalimumab, adalimumabmab, mabmonoclonal, monoclonalxevo, xevotriple, tripleantibody, antibodypolyphenyl, polyphenylsubunit, subunitquadrupole, quadrupolebioresolve, bioresolvealkylation, alkylationplasma
Rapid, Sensitive, and Routine Intact mAb Quantification using a Compact Tof HRMS Platform
2019|Waters|Posters
Rapid, Sensitive, and Routine Intact mAb Quantification using a Compact Tof HRMS Platform Yun W. Alelyunas, Henry Shion, Mark D. Wrona, Weibin Chen, Waters Corporation, Milford, MA INTRODUCTION RESULTS AND DISCUSSION Intact level protein quantification by LC-MS is attractive as…
Key words
bsa, bsaidc, idcrda, rdaintact, intactplasma, plasmabioaccord, bioaccordtrastuzumab, trastuzumabextracted, extractedquantification, quantificationmatrix, matrixuloq, uloqgoat, goatstreptavidin, streptavidinuplc, uplcfinal