C190-E141 Nexera Special Edition LC World Talk SHIMADZU'S NEWSLETTER FOR THE HPLC GLOBAL COMMUNITY SPECIAL EDITION Experience the Evolution of the World’s Only No Compromise UHPLC Continues to Evolve Released as the World’s Only No Compromise UHPLC in March 2010…
Key words
nexera, nexeracarryover, carryoverneedle, needleinjection, injectionrinse, rinsepretreatment, pretreatmentinternal, internalhigh, highmin, minstandard, standardultra, ultraouter, outeranalysis, analysisspeed, speedgradient
The UHPLC with the Ultimate in Resolution
2010|Shimadzu|Technical notes
LAAN-A-LC-E227 Nexera Application Data Sheet No. 3 The UHPLC with the Ultimate in Resolution Nexera supports the use of long analytical columns thereby maximizing separation efficiency thanks to a high pressure limit of up to 130MPa. In this example, two…
Key words
column, columndetection, detectionmin, minbsa, bsatrypsin, trypsinmobile, mobiletfa, tfadigested, digestedflow, flowrate, ratepropiophenone, propiophenoneheptanophenone, heptanophenoneoctanophenone, octanophenonebutyrophenone, butyrophenonehexanophenone
Performance Characteristics of the Agilent 1290 Infinity II Vialsampler Technical Overview Author Abstract Melanie Metzlaff This Technical Overview describes the features and performance of the Agilent Technologies, Inc. Agilent 1290 Infinity II Vialsampler. With a power range up to 1,300…
Key words
rsd, rsdinjection, injectionchlorhexidine, chlorhexidinearea, areaoctanophenone, octanophenonepropiophenone, propiophenoneheptanophenone, heptanophenonebutyrophenone, butyrophenoneacetanilide, acetanilidehexanophenone, hexanophenonevalerophenone, valerophenonemau, mauvialsampler, vialsampleracetophenone, acetophenonephthalate
Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC Technical Overview Authors Introduction Sonja Schneider and Uschi Schweikert The Agilent 1260 Infinity II Bio-inert LC is the next generation of Agilent Bio-inert LC, specially designed for conditions used in…
Key words
mau, maudad, dadtime, timeflow, flowstop, stopcell, cellmin, minbio, bioinert, inertwidth, widthpeak, peakparaben, parabenchromatographic, chromatographiccolumn, columnmobile