Quantification of insulin-like growth factor 1 in human serum by Vanquish UHPLC with Q Exactive high-resolution accurate-mass mass spectrometry for clinical research

Applications | 2019 | Thermo Fischer ScientificInstrumentation
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
Industries
Clinical Research
Manufacturer
Thermo Fischer Scientific
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
LC-MS/MS Quantification of Intact Insulin-Like Growth Factor I(IGF-I) in Serum for Clinical ResearchNikunj Tanna, Mary Lame, Mark Wrona, and Erin ChambersWaters Corporation, Milford, MA, USAAPPLICATION BENEFITS■■■■INTRODUCTIONDirect quantification of intact IGF-IInsulin-like growth factor I (IGF-I) is a 7.6 kDa protein with...
Key words
igf, igfserum, seruminsulin, insulinintact, intactquantification, quantificationgrowth, growthspe, spefactor, factorlike, likearea, areahuman, humanoasis, oasismouse, mousenote, noteppt
TECHNICAL NOTE66048Quantification of total homocysteine in human plasmaor serum by LC-HRAM-MS for clinical researchAuthors: Claudio De Nardi1, Katharina Kern2,Sebastian Berger2Thermo Fisher Scientific GmbH,Dreieich, Germany1RECIPE Chemicals + Instruments GmbH,Munich, Germany2Keywords: Q Exactive Plus MS, TraceFindersoftware, Vanquish Duo UHPLC,high-resolution mass spectrometry,methionine, offline...
Key words
homocysteine, homocysteinebias, biasterms, termsaverage, averagearb, arbcalculated, calculatedpercentage, percentageevaluated, evaluatedassay, assaypump, pumpquantification, quantificationexactive, exactiveclinmass, clinmassanalytical, analyticalnominal
TECHNICAL NOTE73770Fast and accurate quantitation of intact IGF-1from serum by HRAM LC-MS for clinical researchAuthors: Yu Zhou, Xiaolei Xie, andKristine Van NattaThermo Fisher Scientific, San Jose CA, USAKeywords: Orbitrap Exploris 120 massspectrometer, insulin-like growth factor 1,IGF-1, high-resolution accurate-mass (HRAM)mass spectrometry,...
Key words
pass, passpump, pumpvtcc, vtccwaste, wasteserum, serumtrap, trapanalytical, analyticaldata, datacolumn, columnspiked, spikedautosampler, autosamplerloading, loadingoptional, optionalrobustness, robustnesscalibrator
A High-Throughput Integrated HRAM-MS Method Enables IGF-1 Quantification, Targeted Variants Monitoring,and Untargeted Variants Screening in a Single InjectionYu Zhou, Xiaolei Xie, Kristine, Van Natta, Bradley Hart, Shen Luan, Debadeep BhattacharyyaThermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA 95134ABSTRACTRESULTSPurpose:...
Key words
pass, passorbitrap, orbitrapmodified, modifiedmass, massaverage, averagequantification, quantificationexploris, exploriscon, conratio, ratiothermo, thermoduo, duodata, datatracefinder, tracefinderspectrometer, spectrometerscientific