LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Development of simplified quantitative method for tryptic digested C-reactive protein by using online SPE coupled to triple quadrupole mass spectrometer

 

Similar PDF

Toggle
[ APPLICATION NOTE ] Sensitive and Reproducible LC-MS Quantification of C-Reactive Protein in Plasma: A Potential Biomarker of Inflammation Paula Orens, Mary Lame, Steven Calciano, and Erin Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION High sensitivity quantification of…
Key words
esdtsyvslk, esdtsyvslkcrp, crpafvpfk, afvpfkafvfpk, afvfpkconcentration, concentrationpeptide, peptideendogenous, endogenousgysifsyatk, gysifsyatkmean, meanxevo, xevoplasma, plasmacalculated, calculatedoverspike, overspikeconfirmatory, confirmatorynote
SENSITIVE AND REPRODUCIBLE LC-MS QUANTIFICATION OF C-REACTIVE PROTEIN IN PLASMA FOR CLINICAL RESEARCH Paula Orens, Mary Lame, Steven Calciano, and Erin Chambers Waters Corporation 34 Maple Street Milford, MA 01757 RESULTS INTRODUCTION Curve (µg/mL) Weighting Linear Fit (R2) % Accuracy…
Key words
esdtsyvslk, esdtsyvslkcrp, crppeptide, peptidearea, areaafvfpk, afvfpkplasma, plasmaendogenous, endogenouschannelses, channelsesgysifsyatk, gysifsyatkesd, esddigestion, digestiontryptic, trypticafv, afvafvpfk, afvpfklots
[ TECHNOLOGY BRIEF ] Automated and Standardized, Kit-Based Workflow for Protein Quantification Mary Lame, Paula Orens, and Steven Calciano Waters Corporation, Milford, MA, USA Bottom-up, protein quantification workflows are time consuming and complex. A need exists for simpler and standardized…
Key words
proteinworks, proteinworkscrp, crpexpress, expressdigest, digestinfliximab, infliximabkits, kitsasqf, asqfauto, autoafv, afvsins, sinsdill, dilllees, leesesd, esdautomated, automatedtryptic
Shimadzu Liquid Chromatograph Mass Spectrometer LCMS-8060
2019|Shimadzu|Brochures and specifications
C146-E286F Liquid Chromatograph Mass Spectrometer LCMS-8060 CHANGES EVERYTHING Sensitivity Speed Solutions LCMS-8060 The LCMS-8060 pushes the limits of what we can see. Creating the future of LC/MS/MS analysis can mean making something work with higher sensitivity, go faster or cost…
Key words
mrm, mrmlabsolutions, labsolutionsmin, minmediators, mediatorsscan, scansurvey, surveychromatograph, chromatographspectrometer, spectrometermass, massblank, blankinsight, insightspiked, spikedpause, pauseivit, ivitpeptide