Eurachem is a European network promoting international traceability of chemical measurements and good analytical practice. It provides expert guidance, supports method validation, uncertainty evaluation, proficiency testing, and facilitates discussion on technical and policy issues in analytical quality.
Tags
Article
Academy
LinkedIn Logo

Use of uncertainty in compliance

Tu, 21.7.2026
| Original article from: Eurachem
In this leaflet we present the Eurachem/CITAC guide on how to assess compliance with a specification or a regulation.
<p>Eurachem: Use of uncertainty in compliance</p>

Eurachem: Use of uncertainty in compliance

When test results are used to assess compliance, i.e. to decide whether specifications or regulations are met, the measurement uncertainty of the test results has to be taken into account. Assessment of compliance for cases i and v in the Figure below is clear – the measurement results including the uncertainty interval are clearly above or below the limit value. In the other cases the decision is not clear since the uncertainty interval overlaps the limit value. The Eurachem/CITAC guide [1] gives guidance on cases ii, iii and iv. 

Eurachem: Upper control limitEurachem: Upper control limit

We need acceptance & rejection zones 

In order to judge whether the results in cases ii, iii, and iv comply with the limit value we need a decision rule, based on the risks associated with making a wrong decision. This decision rule enables a guard band, g, to be calculated which defines an acceptance zone and a rejection zone. If the measurement value is within the acceptance zone the specifications are met and we can conclude compliance. If the measured value is in the rejection zone, we can conclude non-compliance. The intersection between these two zones is called the decision limit. A guard band is normally chosen so that for a measured value in the acceptance zone the probability of correct acceptance is more than or equal to a defined confidence value α. Note that a guard band, g = 0 can also be used. This is called simple acceptance

Decision rule 

A decision rule should have a well-documented method of determining the location of acceptance and rejection zones, ideally including acceptable levels of probability, P, that the value of the measurand 1) lies within the specification limit, high confidence of correct acceptance (low probability of false acceptance) or 2) lies outside the specification limit, high confidence of correct rejection (low probability of false rejection).

Information needed for assessing compliance 

The following information is needed: 

  • measurand clearly specified; 
  • specification stating upper or lower limit or both; 
  • decision rule; 
  • measured value: 
  • measurement uncertainty for a measured value at the limit(s).

Example focusing on correct acceptance 

  • Measurand: Mass fraction of nickel, Ni in a batch of steel delivered to a customer. 
  • Uncertainty: U = 0.2 % Ni, k = 2 (95 %). Standard uncertainty, u = 0.1 % Ni. This uncertainty includes both sampling uncertainty for the batch and analytical uncertainty. 
  • Specification: The specification zone is from the lower limit 16.0 % Ni to the upper limit 18.0 % Ni. 
  • Decision rule High confidence of correct acceptance: The acceptance range is the mass fraction where it can be decided with a confidence level of approximately 95 % (α = 0.05) that the batch has a mass fraction above the lower limit and below the upper limit. 
  • Guard band: Each guard band is calculated as 1.64u ≈ 0.17 % (rounded upward for safety) with k value 1.64 from the one-tailed upper 95 % quantile of the normal distribution. 
  • Acceptance zone: 16.2 % Ni to 17.8 % Ni , after rounding to one decimal place. 
  • Measured value: 16.1 % Ni

Eurachem: Guard bands (g), and acceptance and a rejection zones based on a lower and upper limit and a decision rule stating high confidence of correct acceptanceEurachem: Guard bands (g), and acceptance and a rejection zones based on a lower and upper limit and a decision rule stating high confidence of correct acceptance

The measured value, 16.1 % Ni, is below the lower acceptance limit of 16.2 %; that is, in the rejection zone. The batch is non-compliant. 

Note – if the decision rule stated simple acceptance the acceptance zone would be 16.0 % to 18.0 % and the batch would be compliant. 

Example focusing on correct rejection 

  • Measurand: Mass fraction of a banned substance in a sample. 
  • Uncertainty: The relative standard uncertainty urel is 35 %. 
  • Specification: Upper limit is 2 ng/g. 
  • Decision rule High confidence of correct rejection: The concentration of the banned substance will be deemed to be above the limit if the probability of the value of the concentration being greater than the limit is 95 % or greater.
  • Guard band: The guard band g for correct rejection is 1.6 ng/g assuming a lognormal distribution (due to the high relative uncertainty – see further Guide Annex A, Case 4 [1]). 
  • Acceptance limit: 3.6 ng/g 
  • Measured value: 3.3 ng/g 

Eurachem: Guard band (g), and acceptance and a rejection zones based on a decision rule stating high confidence of correct rejectionEurachem: Guard band (g), and acceptance and a rejection zones based on a decision rule stating high confidence of correct rejection

The measured value, 3.3 ng/g, is below the acceptance limit of 3.6 ng/g; that is, in the acceptance zone. The sample is compliant. Note that the assumption of the type of distribution is crucial. If assuming a normal distribution in this case the acceptance limit would be 3.2 ng/g and the sample would not be compliant.

Resources

[1] A. Williams and B. Magnusson (eds.) Eurachem/CITAC Guide: Use of uncertainty information in compliance assessment (2nd ed. 2021). Available from www.eurachem.org.

Eurachem
LinkedIn Logo
 

Related content

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Posters
| 2026 | Agilent Technologies (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Proteomics

Mind the pressure in preparative up-scaling – effects of particle size and solvent composition on back pressure

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC, Consumables, LC columns
Manufacturer
KNAUER
Industries
Other

Two-Step Matrix Deposition for Improved MS Imaging Resolution

Posters
| 2026 | Shimadzu (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, MALDI, MS Imaging
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Smart Monitoring & Optimization Solutions for SMB Processes: In-Line and Off-Line Tools for SMB Systems

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC
Manufacturer
KNAUER
Industries
Pharma & Biopharma
 

Related articles

ANALYTIKA - 20% discount on Domifen bromide
Article | Product

ANALYTIKA - 20% discount on Domifen bromide

Domifen bromide – Certified reference material for cosmetic and pharmaceutical research. Now with 20% discount! High-purity CRM (99.22%) characterized by HPLC and ISO 17034 certified.
ANALYTIKA
tag
share
more
Performance Assessment of Binary Output Examinations in Medical Laboratories
Article | Academy

Performance Assessment of Binary Output Examinations in Medical Laboratories

Learn how to assess clinical test performance using sensitivity, specificity, and confidence intervals, and how to define fitness-for-purpose criteria for reliable diagnostic decisions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Important information to our customers concerning the quality of measurements
Article | Academy

Important information to our customers concerning the quality of measurements

Learn why measurement uncertainty is essential for interpreting analytical results, making reliable decisions, comparing laboratory data, and ensuring compliance with modern testing standards.
Eurachem
tag
share
more
 

Related content

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Posters
| 2026 | Agilent Technologies (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Proteomics

Mind the pressure in preparative up-scaling – effects of particle size and solvent composition on back pressure

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC, Consumables, LC columns
Manufacturer
KNAUER
Industries
Other

Two-Step Matrix Deposition for Improved MS Imaging Resolution

Posters
| 2026 | Shimadzu (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, MALDI, MS Imaging
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Smart Monitoring & Optimization Solutions for SMB Processes: In-Line and Off-Line Tools for SMB Systems

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC
Manufacturer
KNAUER
Industries
Pharma & Biopharma
 

Related articles

ANALYTIKA - 20% discount on Domifen bromide
Article | Product

ANALYTIKA - 20% discount on Domifen bromide

Domifen bromide – Certified reference material for cosmetic and pharmaceutical research. Now with 20% discount! High-purity CRM (99.22%) characterized by HPLC and ISO 17034 certified.
ANALYTIKA
tag
share
more
Performance Assessment of Binary Output Examinations in Medical Laboratories
Article | Academy

Performance Assessment of Binary Output Examinations in Medical Laboratories

Learn how to assess clinical test performance using sensitivity, specificity, and confidence intervals, and how to define fitness-for-purpose criteria for reliable diagnostic decisions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Important information to our customers concerning the quality of measurements
Article | Academy

Important information to our customers concerning the quality of measurements

Learn why measurement uncertainty is essential for interpreting analytical results, making reliable decisions, comparing laboratory data, and ensuring compliance with modern testing standards.
Eurachem
tag
share
more
 

Related content

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Posters
| 2026 | Agilent Technologies (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Proteomics

Mind the pressure in preparative up-scaling – effects of particle size and solvent composition on back pressure

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC, Consumables, LC columns
Manufacturer
KNAUER
Industries
Other

Two-Step Matrix Deposition for Improved MS Imaging Resolution

Posters
| 2026 | Shimadzu (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, MALDI, MS Imaging
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Smart Monitoring & Optimization Solutions for SMB Processes: In-Line and Off-Line Tools for SMB Systems

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC
Manufacturer
KNAUER
Industries
Pharma & Biopharma
 

Related articles

ANALYTIKA - 20% discount on Domifen bromide
Article | Product

ANALYTIKA - 20% discount on Domifen bromide

Domifen bromide – Certified reference material for cosmetic and pharmaceutical research. Now with 20% discount! High-purity CRM (99.22%) characterized by HPLC and ISO 17034 certified.
ANALYTIKA
tag
share
more
Performance Assessment of Binary Output Examinations in Medical Laboratories
Article | Academy

Performance Assessment of Binary Output Examinations in Medical Laboratories

Learn how to assess clinical test performance using sensitivity, specificity, and confidence intervals, and how to define fitness-for-purpose criteria for reliable diagnostic decisions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Important information to our customers concerning the quality of measurements
Article | Academy

Important information to our customers concerning the quality of measurements

Learn why measurement uncertainty is essential for interpreting analytical results, making reliable decisions, comparing laboratory data, and ensuring compliance with modern testing standards.
Eurachem
tag
share
more
 

Related content

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Posters
| 2026 | Agilent Technologies (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Proteomics

Mind the pressure in preparative up-scaling – effects of particle size and solvent composition on back pressure

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC, Consumables, LC columns
Manufacturer
KNAUER
Industries
Other

Two-Step Matrix Deposition for Improved MS Imaging Resolution

Posters
| 2026 | Shimadzu (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, MALDI, MS Imaging
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Smart Monitoring & Optimization Solutions for SMB Processes: In-Line and Off-Line Tools for SMB Systems

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC
Manufacturer
KNAUER
Industries
Pharma & Biopharma
 

Related articles

ANALYTIKA - 20% discount on Domifen bromide
Article | Product

ANALYTIKA - 20% discount on Domifen bromide

Domifen bromide – Certified reference material for cosmetic and pharmaceutical research. Now with 20% discount! High-purity CRM (99.22%) characterized by HPLC and ISO 17034 certified.
ANALYTIKA
tag
share
more
Performance Assessment of Binary Output Examinations in Medical Laboratories
Article | Academy

Performance Assessment of Binary Output Examinations in Medical Laboratories

Learn how to assess clinical test performance using sensitivity, specificity, and confidence intervals, and how to define fitness-for-purpose criteria for reliable diagnostic decisions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Important information to our customers concerning the quality of measurements
Article | Academy

Important information to our customers concerning the quality of measurements

Learn why measurement uncertainty is essential for interpreting analytical results, making reliable decisions, comparing laboratory data, and ensuring compliance with modern testing standards.
Eurachem
tag
share
more
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike