The Agilent LC 1200 series is an advanced liquid chromatograph that provides excellent performance for all types of applications.
💡 We are happy to provide you with the configuration needed for your application, individual modules or spare parts. Send us an inquiry.
A secure investment in your lab's future with the scalable and open architecture of the Agilent 1200 series liquid chromatographs.
Seamless integration of individual modules provides unmatched precision and accuracy for quantitative and qualitative analysis. Highly sensitive detectors provide the lowest possible detection limits for even the most demanding applications.
Module Selection Guide
Agilent 1200 Series Pumps/Pumps
Isocratic Pump
- Flow range: 0.2 - 10 ml/min, for isocratic analysis
- Column ID: 2.1 - 9.4 mm
Quaternary Pump
- Flow range: 0.2 - 10 ml/min, for gradient analysis
- Column ID: 3 - 9.4 mm
Binary Pump
-
Flow range: 0.05 - 5 ml/min, for rapid gradient analysis
-
Column ID: 2.1 - 4.6 mm
-
Flow range: 0.05 - 5 ml/min, for very fast gradient and high resolution analysis
-
Column ID: 1 - 4.6 mm
Preparative Pump
- Flow range: 0.5 - 100 ml/min (expandable to binary gradient) for isolation and purification
- Column ID: 4.6 - 50 mm
Microflow pump
- Flow range: 1 - 100 μl/min (expandable up to 2.5 ml/min), for gradient analysis
- Column ID: 0.18 - 1 mm
Nanoflow pump
- Flow range: 0.1 - 1 μl/min (expandable up to 2.5 ml/min), for gradient analysis
- Column ID: 0.075 - 0.1 mm
Agilent 1200 Series Column/Valve Organization
Column thermostat
- Temperature range: 10 °C below ambient to 80 °C
- Temperature range: 10 °C below ambient up to 100 °C
Column/Valve Organizer
- Standard column mounting outside the HPLC system
Agilent Interface
- 35900 A/D converter for connecting non-Agilent modules
Agilent 1200 Series Dispensing Systems
Manual Dispensers
- Injection range: loops for 5 μl - 20 ml
Autosamplers (standard, high performance)
- Injection range: 0.1 μL - 100 μL (expandable up to 5000 μL)
- Sample container: vials
Autosampler PS with two loops
- Injection range: up to 10 mL
- Sample container: vials and plates
Autosampler for microtiter plates
- Injection range: 0.01 - 8 μl (expandable up to 40 μl)
- Sample container: vials and plates
Preparative autosampler
- Spray range: 0.1 - 5000 μl.
- Sample container: vials
Thermostat for autosampler
- Temperature range: 4 - 40 °C
Agilent 1200 Series Degassers/Gassers
Degaser/Vacuum degasser mobile phase
- Flow rate: up to 10 ml/min. Internal volume: 12 ml
Microdegaser
- Flow rate: up to 5 ml/min. Internal volume: 1 ml
Agilent 1200 Series Fractional Collectors
Microcollector/spotter and fraction collector (AS, PS)
- Flow rate: up to 100 μl/min
- Flow rate: up to 10 ml/min
- Flow rate: up to 100 ml/min
Agilent 1200 Series Detectors
Variable wavelength detector
- for programmable single wavelength analysis, 1 signal, 13 Hz acquisition rate
- for ultra-fast, programmable single wavelength analysis, 1 signal, data acquisition rate 55 Hz
Multiple Wavelength Detector
- for detection of up to 5 wavelengths, data acquisition rate 20 Hz
- for ultra-fast detection of up to 8 wavelengths, data acquisition rate 80 Hz
Diode array detector
- for multi-λ and spectral analysis of 5 wavelengths, data acquisition rate 20 Hz
- for ultrafast multi-λ and spectral analysis up to 8 wavelengths, data acquisition rate 80 Hz
Fluorescence detector
- for online detection of multiple signals and fluorescence spectra
Refractive Index Detector
- for refractive index range: 1.00 - 1.75 calibrated
Agilent 1200 Series External Valves
- Two-position/10-port valve
- 2-position/10-port microvalve
- 2-position/6-port valve
- 2-position/6-port micro valve
- 6-position selector valve
- 12-position/13-port valve
Data handling, collection and evaluation
Agilent 1200 Series Instant Pilot
Agilent workstations and chromatography data systems
Speed and throughput
By choosing the optimal system from fast quaternary/binary LC to higher resolution ultrafast system, you can reach new levels of productivity, process more samples in less time while maintaining or even improving data quality.
The Short columns with particle sizes below 2 μm offer a unique opportunity to dramatically reduce analysis time by increasing throughput without sacrificing separation performance. To take full advantage of their performance, you need a system that can handle more than just high backpressure. The answer is a fully integrated solution, optimized system dead volume, short analysis time, speed of detection and temperature control.
Altium: Agilent 1200 series HPLC system - a scalable solution
Reliability and durability
Easy maintenance and intelligent system monitoring for increased uptime.
With an installed base of more than 60,000 HPLC systems, Agilent is renowned for its reliability under all operating conditions. The Agilent 1200 Series represents a new generation of LCs designed for even greater robustness and reliability along with higher performance.
Agilent has pioneered technologies for monitoring and tracking critical system parameters to achieve higher productivity and keep operating costs low.
Altium: Self-adjusting, access to spare parts from the front. Built-in DAD SL data recovery card offers you data insurance.
Preparative HPLC solution
-
Flow rates of microsystem for collection/spotting up to 100 μl/min
-
Analytical Scale Purification System Flow rates up to 10 ml/min
-
Purification system Preparative scale Flow rates up to 100 ml/min
Altium: Agilent 1200 series HPLC System - Preparative HPLC Solutions