LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Seller
LabRulez
Stop looking and start finding. We are your source for news, applications, products, articles, theory, job postings, webinars, e-shop or bazaar in the world of analytical chemistry.
Manufacturer
Agilent Technologies
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.

Agilent 1260 Infinity II HPLC MWD Detector (G7165A) (New)

The Agilent 1260 Infinity II Multiple Wavelength Detector (MWD) is an advanced liquid chromatography (LC) detector designed for high-performance multi-wavelength analysis. Engineered for superior sensitivity, selectivity, and operational efficiency, this detector enables simultaneous detection of up to eight compound-specific wavelengths within a broad 190–950 nm range.
Purchase price
10,500
without VAT
In stock
+ 100  delivery

Features

Condition:
New
Warranty:
3 months
Manufacture year:
2022
Countries:
Czech Republic
Additional services
Advanced training
Installation
Extended warranty
Basic training
Application implementation

Features

The Agilent 1260 Infinity II Multiple Wavelength Detector (MWD) is an advanced liquid chromatography (LC) detector designed for high-performance multi-wavelength analysis. Engineered for superior sensitivity, selectivity, and operational efficiency, this detector enables simultaneous detection of up to eight compound-specific wavelengths within a broad 190–950 nm range.

Built with Agilent’s state-of-the-art diode array technology, the detector delivers ultra-low noise levels (< ±7 μAU), ensuring accurate quantification of trace-level compounds. With a high-speed 120 Hz data acquisition rate, it supports fast LC applications while maintaining high resolution. The electronic temperature control (ETC) stabilizes baseline performance under fluctuating environmental conditions, optimizing both sensitivity and linearity.

Ideal for analytical laboratories, the 1260 Infinity II MWD ensures high data integrity through radio frequency identification (RFID) tracking of flow cells and UV lamps, automatic wavelength verification, and compliance with Good Laboratory Practice (GLP) requirements. 

Technical Specification

General Information

  • Model: Agilent 1260 Infinity II Multiple Wavelength Detector (G7165A)
  • Detection Type: 1024-element photodiode array
  • Wavelength Range: 190 – 950 nm
  • Data Rate: Up to 120 Hz
  • Light Source: Deuterium and tungsten lamps (with RFID tracking)
  • Wavelength Accuracy: ±1 nm (self-calibration with deuterium lines, holmium oxide filter verification)
  • Slit Widths: Programmable (1, 2, 4, 8, 16 nm)
  • Time-Programmable Features: Wavelength, polarity, peak width, lamp bandwidth, auto-balance, wavelength range, threshold, spectra storage mode

Performance Specifications

  • Short-Term Noise (ASTM, Single & Multi-Wavelength): < ±7 µAU at 254 and 750 nm
  • Drift: < 0.9 x 10⁻³ AU/h at 254 nm
  • Linear Absorbance Range: > 2 AU (5 %) at 265 nm
  • Diode Width: < 1 nm
  • pH Range: 1.0 – 9.5 (12.5 solvent dependent with bio-inert version)

Flow Cell Options

  • Standard Flow Cell: 13 µL volume, 10 mm path length, 120 bar pressure limit
  • Micro Flow Cell: 2 µL volume, 3 mm path length, 120 bar pressure limit
  • Nano Flow Cell: 80 nL volume, 6 mm path length, 50 bar pressure limit
  • High-Pressure Flow Cell: 1.7 µL volume, 6 mm path length, 400 bar pressure limit
  • Preparative & SFC Flow Cells: Various options with path lengths from 0.06 mm to 10 mm and pressure limits from 20 bar to 400 bar
  • RFID Tracking: All flow cells include embedded RFID tags for traceability and security

Physical & Environmental Parameters

  • Weight: 12 kg (26.5 lbs)
  • Dimensions (H × W × D): 140 × 396 × 436 mm (5.5 × 15.6 × 17.0 inches)
  • Power Requirements: 100–240 V~, 50/60 Hz, 110 VA / 100 W
  • Operating Temperature: 4–55 °C (39–131 °F)
  • Storage Temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95% RH at 40°C (non-condensing)
  • Altitude: Up to 3000 m (operating), 4600 m (non-operating)
  • Safety Standards Compliance: IEC, EN, CSA, UL (Installation Category II, Pollution Degree 2)

Connectivity & Control

  • Instrument Control: Agilent Lab Advisor B.02.08 or above
  • Local Control: Agilent Instant Pilot (G4208A) B.02.20 or above
  • Interfaces: Controller Area Network (CAN), USB, Extended Remote Interface (ERI)
  • Analog Outputs: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs

Compliance & Maintenance

  • GLP Features: RFID-based tracking for UV lamps and flow cells, early maintenance feedback (EMF), error logging
  • Diagnostics & Safety: Leak detection, safe leak handling, automatic shutdown signals
  • Housing Material: Fully recyclable materials

The Agilent 1260 Infinity II MWD meets the highest industry standards for precision, reliability, and data security. It is an ideal solution for laboratories requiring advanced chromatographic analysis with robust, high-performance detection capabilities.

Seller
LabRulez
Stop looking and start finding. We are your source for news, applications, products, articles, theory, job postings, webinars, e-shop or bazaar in the world of analytical chemistry.
Manufacturer
Agilent Technologies
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike