Agilent 1290 Infinity II Evaporating Light Scattering Detector (ELSD) in Empower Environment
Technical notes | 2017 | Agilent TechnologiesInstrumentation
Liquid chromatography coupled with evaporative light scattering detection (ELSD) enables sensitive analysis of non-UV-active analytes across pharmaceuticals, food safety and environmental monitoring. Integrating the Agilent 1290 Infinity II ELSD with Waters Empower 3 streamlines instrument control, enhances data integrity and supports compliance with regulatory standards.
This guide presents a step-by-step procedure to configure and operate the Agilent 1290 Infinity II ELSD within the Waters Empower 3 environment. It covers supported hardware/software versions, instrument installation, communication setup and method integration in Empower.
Instrument setup begins by powering down the LC system, installing the ELSD module and ensuring all firmware versions meet or exceed vendor requirements. Communication can be established via RS-232 or LAN with fixed IP addressing. The Agilent PreConfiguration Utility within Empower’s Configuration Manager is used to register ELSD modules, assign COM ports or IP addresses and synchronize instrument definitions. Finally, Empower methods are updated to include ELSD operational parameters.
Once configured, the ELSD appears in Empower’s LC Status Dashboard alongside other Agilent modules. Real-time plots display ELSD signals and auxiliary traces, while the diagnostic logbook captures audit trails and error messages. Users can control ELSD start/stop timing independently or employ Empower’s selective shutdown feature. Limitations include absence of analog outputs on certain ELSD models and unverified USB-to-serial adapters.
Coupling ELSD with Empower consolidates control of non-UV-active analyte detection, reduces manual setup errors and centralizes data management. Laboratories gain improved method reproducibility, full traceability through audit logs and flexible instrument shutdown protocols that protect hardware.
Emerging developments in detector communication protocols, enhanced firmware interoperability and cloud-based data processing will facilitate remote monitoring and real-time method optimization. Integration with artificial intelligence and advanced analytics may further extend ELSD capabilities in high-throughput and automated laboratories.
The Agilent 1290 Infinity II ELSD integration with Waters Empower 3 delivers a robust, user-friendly workflow for detecting non-UV-active compounds. By following recommended installation and configuration steps, users can achieve reliable performance and leverage ongoing software and firmware enhancements to broaden analytical applications.
Software, HPLC
IndustriesPharma & Biopharma
ManufacturerAgilent Technologies, Waters
Summary
Importance of the Topic
Liquid chromatography coupled with evaporative light scattering detection (ELSD) enables sensitive analysis of non-UV-active analytes across pharmaceuticals, food safety and environmental monitoring. Integrating the Agilent 1290 Infinity II ELSD with Waters Empower 3 streamlines instrument control, enhances data integrity and supports compliance with regulatory standards.
Objectives and Overview of the Study
This guide presents a step-by-step procedure to configure and operate the Agilent 1290 Infinity II ELSD within the Waters Empower 3 environment. It covers supported hardware/software versions, instrument installation, communication setup and method integration in Empower.
Methodology and Instrumentation Used
Instrument setup begins by powering down the LC system, installing the ELSD module and ensuring all firmware versions meet or exceed vendor requirements. Communication can be established via RS-232 or LAN with fixed IP addressing. The Agilent PreConfiguration Utility within Empower’s Configuration Manager is used to register ELSD modules, assign COM ports or IP addresses and synchronize instrument definitions. Finally, Empower methods are updated to include ELSD operational parameters.
Main Results and Discussion
Once configured, the ELSD appears in Empower’s LC Status Dashboard alongside other Agilent modules. Real-time plots display ELSD signals and auxiliary traces, while the diagnostic logbook captures audit trails and error messages. Users can control ELSD start/stop timing independently or employ Empower’s selective shutdown feature. Limitations include absence of analog outputs on certain ELSD models and unverified USB-to-serial adapters.
Benefits and Practical Applications
Coupling ELSD with Empower consolidates control of non-UV-active analyte detection, reduces manual setup errors and centralizes data management. Laboratories gain improved method reproducibility, full traceability through audit logs and flexible instrument shutdown protocols that protect hardware.
Future Trends and Potential Applications
Emerging developments in detector communication protocols, enhanced firmware interoperability and cloud-based data processing will facilitate remote monitoring and real-time method optimization. Integration with artificial intelligence and advanced analytics may further extend ELSD capabilities in high-throughput and automated laboratories.
Conclusion
The Agilent 1290 Infinity II ELSD integration with Waters Empower 3 delivers a robust, user-friendly workflow for detecting non-UV-active compounds. By following recommended installation and configuration steps, users can achieve reliable performance and leverage ongoing software and firmware enhancements to broaden analytical applications.
Instrumentation Used
- Agilent 1290 Infinity II Evaporative Light Scattering Detector models G4260B and G7102A
- Waters Empower 3 CDS with ICF Support v2.2 and LC driver A.02.14
- RS-232 and LAN communication interfaces (minimum firmware 31.06)
- Agilent PreConfiguration Utility for Empower
References
- Waters Technical Note TECN134936402 Using the Agilent PreConfiguration Utility with Agilent ICF Support Version 2.2
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Using ISET in Empower Environment - Technical Note
2019|Agilent Technologies|Manuals
Using ISET in Empower Environment Technical Note Technical Guide for the configuration and use of the Agilent Intelligent System Emulation Technology (ISET) G2197AA with Waters Empower Introduction 2 Prerequisites/Compatibility Information 3 ISET Trial 4 End of Trial Period Requires Reconfiguration…
Key words
iset, isetempower, empowerpreconfiguration, preconfigurationtrial, trialpictogram, pictogramicf, icfagilent, agilentconfiguration, configurationnote, notesupported, supportedusing, usingprerequisites, prerequisitesdashboard, dashboardperiod, periodversion
Performing Manual Injection (LC) in Empower Environment - Technical Note
2020|Agilent Technologies|Manuals
Performing Manual Injection (LC) in Empower Environment Technical Note Technical Guide for the configuration and usage of the G1328A-D and G5628A Agilent Manual Injectors with Waters Empower. Introduction 2 Prerequisites/Compatibility Information 3 Using the Manual Injector in the Agilent LC…
Key words
empower, empowersupported, supportedmanual, manualpreconfiguration, preconfigurationoutlined, outlinedagilent, agilenticf, icfinjector, injectorprerequisites, prerequisitesusing, usingwaters, watersnote, noteconfiguration, configurationcompatibility, compatibilityinjectors
Using High Dynamic Range (HDR) in Empower Environment
2017|Agilent Technologies|Technical notes
Using High Dynamic Range (HDR) in Empower Environment Technical Note HDR in Empower This is a technical guide for the configuration of the High Dynamic Range (HDR) option with two Agilent DADs in a Waters Empower 3 environment. Contents Introduction…
Key words
hdr, hdrempower, empowerconfigure, configureset, setconfiguration, configurationcluster, clusterinstrument, instrumentdad, dadsystem, systemagilent, agilentnote, notelac, lacpre, preinstrumentpreconfigurator, instrumentpreconfiguratordhcp
Agilent ICF Support Layer for Waters CDS Release Notes – Revision 4.2
2025|Agilent Technologies|Manuals
Agilent ICF Support Layer for Waters CDS Release Notes – Revision 4.2 Notices Manual Part Number Warranty D0128450 The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further,…
Key words
supported, supportedicf, icfagilent, agilentfirmware, firmwaredriver, driverwicf, wicfmodules, modulesempower, empowersupport, supporttower, towerinstrument, instrumentinficfsl, inficfslwaters, watersabort, abortissues