LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Controlling the Agilent 1260 Infinity/1290 Infinity II Multisampler (G7167A/B) in Waters Empower 3 Environment

Technical notes | 2017 | Agilent TechnologiesInstrumentation
Software, HPLC
Industries
Pharma & Biopharma
Manufacturer
Agilent Technologies, Waters

Summary

Significance of the Topic


Automated sampling with liquid chromatography modules is essential for high-throughput laboratories, reducing manual error and improving data quality. Integrating the Agilent 1260 Infinity/1290 Infinity II Multisamplers with Waters Empower 3 through the Agilent Instrument Control Framework (ICF) enables seamless instrument management in third-party chromatography data systems.

Objectives and Study Overview


This technical note provides step-by-step instructions for configuring and controlling the Agilent Multisampler in Waters Empower 3. It covers prerequisites, well plate definition, method setup, and sample analysis workflows.

Methodology and Instrumentation Used


  • Agilent ICF and Waters Instrument Control Software to bridge communication between Empower 3 and Agilent LC hardware
  • Required firmware and software: Multisampler firmware Rev. D.06.60 or higher; Waters ICS 2.1 Hotfix with Agilent ICF A.02.03 DU1 HF2 and ICF-LC Driver A.02.11 SP1
  • Empower system configuration via DHCP-based instrument detection, module scanning, and chromatographic system creation
  • Well plate import or manual definition in Empower, assignment to Multisampler drawers, and capillary configuration
  • Instrument method setup in Empower including injection parameters, cleaning routines, and priming

Main Results and Discussion


The guide confirms reliable control of the Multisampler through Empower 3, ensuring correct mapping of plate types and system modules. It enables both single and series injections, with optional cleaning protocols to minimize carryover and maintain performance.

Benefits and Practical Applications of the Method


  • Faster method development using standardized ICF drivers
  • Improved reproducibility for pharmaceutical, environmental, and biochemical screening
  • Flexible plate and cleaning configurations support diverse sample needs
  • Third-party CDS compatibility expands integration across laboratory environments

Future Trends and Potential Applications


Emerging developments may include cloud-based CDS integration, AI-driven sampling optimization, support for new microplate formats, and advanced self-diagnostics to further reduce downtime in automated workflows.

Conclusion


Utilizing Agilent Multisamplers with Waters Empower via ICF offers a robust solution for automated sample handling, enhancing laboratory efficiency, data integrity, and throughput. The documented configuration and cleaning procedures support modern analytical demands.

References


No external literature references were provided in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent Infinity Lab LC Series Vialsampler Vial Drawer Configuration in Empower Environment - Technical Note
Agilent Infinity Lab LC Series Vialsampler Vial Drawer Configuration in Empower Environment Technical Note Technical Guide for the vial drawer configuration and setup of the G7129A/B/C Vialsampler with Waters Empower. Introduction Offered Vial Drawers for Vialsamplers 2 2 Prerequisites/Compatibility Information…
Key words
vialsamplers, vialsamplersdrawer, drawerempower, empoweraddressing, addressingvial, vialdrawers, drawersalphanumeric, alphanumericsteps, stepsicf, icfprerequisites, prerequisitesadditional, additionalvialsampler, vialsamplerappendix, appendixagilent, agilentlocation
Using the Fraction Collector in Empower 3 Environment - Technical Note
Using the Fraction Collector in Empower 3 Environment Technical Note Technical Guide for the configuration and use of the Agilent Fraction Collectors with Waters Empower Introduction 2 Adding the Fraction Collector to the Agilent LC Instrument System 4 Configuration of…
Key words
collector, collectorfraction, fractionempower, empowertray, trayconfiguration, configurationwellplates, wellplatesrun, runwellplate, wellplatesupported, supporteduse, useagilent, agilentnote, notetube, tubevia, vialac
Using ISET in Empower Environment - Technical Note
Using ISET in Empower Environment Technical Note Technical Guide for the configuration and use of the Agilent Intelligent System Emulation Technology (ISET) G2197AA with Waters Empower Introduction 2 Prerequisites/Compatibility Information 3 ISET Trial 4 End of Trial Period Requires Reconfiguration…
Key words
iset, isetempower, empowerpreconfiguration, preconfigurationtrial, trialpictogram, pictogramicf, icfagilent, agilentconfiguration, configurationnote, notesupported, supportedusing, usingprerequisites, prerequisitesdashboard, dashboardperiod, periodversion
Agilent ICF Support Layer for Waters CDS Release Notes – Revision 4.2
Agilent ICF Support Layer for Waters CDS Release Notes – Revision 4.2 Notices Manual Part Number Warranty D0128450 The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further,…
Key words
supported, supportedicf, icfagilent, agilentfirmware, firmwaredriver, driverwicf, wicfmodules, modulesempower, empowersupport, supporttower, towerinstrument, instrumentinficfsl, inficfslwaters, watersabort, abortissues
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike