Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System
Applications | 2018 | Agilent TechnologiesInstrumentation
In natural product analysis for food additives and dietary supplements, organic impurities can compromise product quality, safety, and regulatory compliance. Effective methods to isolate and identify low-level impurities are essential for quality control, toxicity assessment, and ensuring adherence to ICH guidelines on impurity characterization.
This work presents a complete workflow for mass-based purification of unknown impurities in a natural product extract. The study encompasses analytical scouting, scale-up to preparative conditions, and targeted fraction collection using an Agilent 1260 Infinity II LC/MSD System and its preparative counterpart. Two unknown impurities at <0.5 % of the main compound were identified, isolated, and purified for further characterization.
Analytical Scouting:
Preparative Purification:
Analytical scouting resolved the main compound and two unknown impurities (m/z 823.4 and 839.4) despite column overload. Preparative runs maintained retention time reproducibility within 0.2 min and achieved baseline separation of target impurities from the main peak. Mass-and UV-triggered fraction collection delivered high specificity. Reanalysis of collected fractions confirmed purity >98 %, demonstrating the effectiveness of the combined UV/MS approach in preparative isolation.
Continued integration of high-resolution MS and advanced ion-mobility techniques could improve impurity profiling. Automation of scale-up protocols and real-time data feedback will accelerate method development. Emerging AI-driven software may further optimize trigger settings and purity predictions, enhancing preparative workflows in food, pharmaceutical, and natural product research.
The described workflow demonstrates a robust, scalable approach for mass-based purification of low-level impurities in natural product extracts. By combining analytical scouting, linear scale-up, and mass-triggered fraction collection on Agilent 1260 Infinity II systems, highly pure fractions (>98 %) were obtained, facilitating subsequent characterization and ensuring compliance with quality standards.
PrepLC
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Significance of the Topic
In natural product analysis for food additives and dietary supplements, organic impurities can compromise product quality, safety, and regulatory compliance. Effective methods to isolate and identify low-level impurities are essential for quality control, toxicity assessment, and ensuring adherence to ICH guidelines on impurity characterization.
Objectives and Study Overview
This work presents a complete workflow for mass-based purification of unknown impurities in a natural product extract. The study encompasses analytical scouting, scale-up to preparative conditions, and targeted fraction collection using an Agilent 1260 Infinity II LC/MSD System and its preparative counterpart. Two unknown impurities at <0.5 % of the main compound were identified, isolated, and purified for further characterization.
Methodology and Instrumentation
Analytical Scouting:
- System: Agilent 1260 Infinity II Binary Pump, Vialsampler, Diode Array Detector WR, LC/MSD XT.
- Column: Agilent Prep-C18 Scalar 4.6 × 100 mm, 5 µm.
- Mobile phases: A) 0.1 % formic acid in water; B) 0.1 % formic acid in methanol.
- Gradient: 0 min 30 % B to 20 min 80 % B; flow 1 mL/min; injection 20 µL; UV at 297 nm; MSD positive scan m/z 500–1,000 and SIM m/z 823.4, 839.4.
Preparative Purification:
- System: Agilent 1260 Infinity II Preparative Binary Pump, Autosampler, Column Organizer, Variable Wavelength Detector, Isocratic Pump, 1290 Infinity II MS Flow Modulator, Delay Coil Organizer, Preparative Open-Bed Fraction Collector, LC/MSD XT.
- Column: Agilent Prep-C18 21.2 × 100 mm, 5 µm.
- Scale-up: linear dimension scaling, flow 20 mL/min; injection 900 µL; same gradient as analytical.
- Fraction collection: AND trigger combining UV and SIM signals; split ratio control via MS Flow Modulator to protect MSD; mass-based triggers for target ions.
- Make-up solvent: 0.1 % formic acid in methanol:water (70:30), 1.5 mL/min.
Key Results and Discussion
Analytical scouting resolved the main compound and two unknown impurities (m/z 823.4 and 839.4) despite column overload. Preparative runs maintained retention time reproducibility within 0.2 min and achieved baseline separation of target impurities from the main peak. Mass-and UV-triggered fraction collection delivered high specificity. Reanalysis of collected fractions confirmed purity >98 %, demonstrating the effectiveness of the combined UV/MS approach in preparative isolation.
Benefits and Practical Applications
- High-throughput isolation of trace impurities for structural and toxicity studies.
- Scalable method from analytical scouting to preparative purification with matching columns.
- Mass-based fraction triggers enhance selectivity and reduce solvent consumption.
- Integrated software control enables automated split control, fraction timing, and data review.
Future Trends and Potential Uses
Continued integration of high-resolution MS and advanced ion-mobility techniques could improve impurity profiling. Automation of scale-up protocols and real-time data feedback will accelerate method development. Emerging AI-driven software may further optimize trigger settings and purity predictions, enhancing preparative workflows in food, pharmaceutical, and natural product research.
Conclusion
The described workflow demonstrates a robust, scalable approach for mass-based purification of low-level impurities in natural product extracts. By combining analytical scouting, linear scale-up, and mass-triggered fraction collection on Agilent 1260 Infinity II systems, highly pure fractions (>98 %) were obtained, facilitating subsequent characterization and ensuring compliance with quality standards.
References
- ICH Guideline Q3A(R2): Impurities in New Drug Substances, 2006.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Purification of Cannabinoids from a Cannabis sativa Extract
2020|Agilent Technologies|Applications
Application Note Food Testing & Agriculture Purification of Cannabinoids from a Cannabis sativa Extract Author Florian Rieck Agilent Technologies, Inc. Abstract With the growth of cannabinoid-containing products offered by the food, cosmetics, and healthcare industry, isolation of single cannabinoids to…
Key words
fraction, fractionmsd, msdcannabinoids, cannabinoidscollection, collectioncbd, cbdpreparative, preparativecps, cpspurification, purificationmin, minscouting, scoutingcannabis, cannabisanalytical, analyticalsim, simtetrahydrocannabivarin, tetrahydrocannabivarinvisible
Fast and Selective Purification of Oligonucleotides Using Preparative HPLC/MS and Software Support
2022|Agilent Technologies|Applications
Application Note Biopharma/Pharma Fast and Selective Purification of Oligonucleotides Using Preparative HPLC/MS and Software Support mAU UV 800 400 0 cps 80,000 2 4 6 8 10 12 min 2 4 6 8 10 12 min 2 4 6 8…
Key words
fraction, fractionpurification, purificationflp, flppreparative, preparativemsd, msdcollection, collectionmin, minhfip, hfipwere, weredba, dbacps, cpsmau, mautrigger, triggerruns, runsoligonucleotides
Reduce Your Purification Footprint: Scouting, Collection, and Reanalysis in Well Plates on a Single System
2020|Agilent Technologies|Technical notes
Technical Overview Reduce Your Purification Footprint: Scouting, Collection, and Reanalysis in Well Plates on a Single System Author Florian Rieck Agilent Technologies, Inc. Abstract Typical purification workflows using high-performance liquid chromatography (HPLC) involve two systems: the analytical system is used…
Key words
preparative, preparativefractions, fractionspurification, purificationdilution, dilutionfraction, fractionsample, samplescouting, scoutingtarget, targetcollection, collectionmsd, msdanalytical, analyticalreinjection, reinjectionsoftware, softwaresamples, samplessandwich
Isolate and Reanalyze Pharma Impurities with the Agilent 1290 Infinity II Autoscale Preparative LC/MSD System
2020|Agilent Technologies|Applications
Application Note Pharmaceutical Small Molecules Isolate and Reanalyze Pharma Impurities with the Agilent 1290 Infinity II Autoscale Preparative LC/MSD System API Author Florian Rieck Agilent Technologies, Inc. Abstract Isolation of impurities for further characterization is a routine task in the…
Key words
preparative, preparativefraction, fractionmsd, msdreanalysis, reanalysisscale, scalefractions, fractionsinjection, injectionmau, maureanalyzed, reanalyzedimpurities, impuritiesanalytical, analyticalsampler, sampleropen, openautoscale, autoscalecollector