Summary

Importance of the Topic


Fluorescence detection plays a central role in modern analytical chemistry by offering exceptional sensitivity and selectivity for trace-level compounds. Its ability to discriminate target analytes through specific excitation and emission wavelengths makes it indispensable for applications where ultraviolet absorption is insufficient. Moreover, fluorescence detectors remain cost-effective and user-friendly compared with more complex mass spectrometry systems, ensuring regulatory compliance and routine use in quality control, pharmaceutical, environmental, and food laboratories.

Objectives and Study Overview


This report presents the fundamental principles of fluorescence detection and demonstrates advances in detector design using the Shimadzu Prominence RF-20AXS. Key objectives include:
  • Explaining fluorescence mechanisms and detector characteristics
  • Investigating factors affecting signal stability (dissolved oxygen, temperature)
  • Describing innovations in the RF-20AXS optical and thermal control systems
  • Illustrating performance through real-world applications (anthracene, veterinary drugs, surfactants, PAHs, amino acids, pesticides, sugars)

Methodology and Instrumentation


Fluorescence detection involves irradiating a sample with a fixed excitation wavelength and measuring emitted photons at a longer emission wavelength. To maximize performance, the following approaches were used:
  • Online and offline degassing (DGU-20A3/A5, ultrasonic unit) to prevent oxygen quenching
  • Temperature-controlled flow cell and photomultiplier tube in RF-20AXS to maintain constant detector conditions
  • High-efficiency optical design delivering ~100× more light throughput compared with prior models
  • Fast 100 Hz data acquisition and a low-volume cell for ultra-fast separations
  • Shim-pack columns and tailored mobile phases for each application

Used Instrumentation:
  • Shimadzu Prominence RF-20AXS fluorescence detector
  • DGU-20A3/A5 on-line degasser and ultrasonic degassing unit
  • Shim-pack XR-ODS, CLC-SIL, Amino-Na, ISA-07 columns
  • High-performance LC system for ultra-fast analysis

Main Results and Discussion


Key findings include:
  • Oxygen dissolved in mobile phase causes fluorescence quenching; stable degassing restored signal consistency
  • Detector cell temperature fluctuations (1 °C) led to up to 5 % signal change; RF-20AXS temperature control ensured <1 % variation
  • Anthracene trace analysis achieved a detection limit of ~1.5 fg (S/N=3)
  • Ultra-fast tocopherol separations maintained resolution with high sensitivity (N>10,000)
  • Enrofloxacin calibration was linear from 0.05 to 1,000 µg/L (LOD 0.05 µg/L)
  • Direct injection of linear alkylbenzene sulfonates simplified water analysis; run time cut by 80 %
  • Simultaneous multi-wavelength detection of 15 PAHs at 100 Hz ensured correct peak assignment
  • Amino acid and carbamate pesticide assays showed 4–5× and robust repeatability (<3 %RSD)
  • Reducing sugar derivatives exhibited 10–20× sensitivity improvement over previous models

Benefits and Practical Applications


Fluorescence detection with the RF-20AXS offers:
  • High selectivity for target compounds via wavelength tuning
  • Ultra-low detection limits for environmental pollutants, drugs, and biomolecules
  • Excellent repeatability under varying laboratory conditions
  • Cost-effective maintenance and long-term stability
  • Compatibility with regulated analytical methods in food safety, water quality, and pharmaceuticals

Future Trends and Possibilities


Emerging directions include:
  • Miniaturized, portable fluorescence detectors for field analysis
  • Integration with microfluidic and lab-on-chip platforms
  • Automated multi-mode detection combining fluorescence with absorbance or MS
  • Advanced chemometric tools and AI for real-time method optimization

Conclusion


The Shimadzu Prominence RF-20AXS exemplifies the next generation of fluorescence detectors, delivering transformative sensitivity, stability, and speed. By addressing key factors such as oxygen quenching and temperature control, it enables a broad range of applications—from trace environmental monitoring to rapid pharmaceutical assays—while maintaining cost-effective operation and compliance with regulatory standards.

References


No formal references were cited in the original text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Fluorescence Detectors for HPLC - RF-20A RF-20Axs
Fluorescence Detectors for HPLC - RF-20A RF-20Axs
2024|Shimadzu|Brochures and specifications
C193-E026D Fluorescence Detectors for High Performance Liquid Chromatograph RF-20A RF-20Axs Prominent Sensitivity… The excellent basic performance of the Nexera™ / Prominence™ series is further enhanced by the RF-20A/20Axs fluorescence detectors, which offer world-class sensitivity, excellent ease of maintenance, and validation…
Key words
wavelength, wavelengthcell, celltemperature, temperaturebenzo, benzoanthracene, anthraceneanalysis, analysisshim, shimunits, unitssemimicro, semimicropack, packsystem, systemfluorescence, fluorescenceacetylcysteine, acetylcysteineflow, flowphthalaldehyde
Application Handbook Liquid Chromatography
Application Handbook Liquid Chromatography Introduction HPLC, UHPLC as well as SFC systems are able to quantitatively analyze substances in mixtures containing multiple ingredients by separating and detecting target substances. They are used to separate, quantify, qualify or purify single components…
Key words
sfe, sfeflowrate, flowrateprominence, prominencenews, newsnexera, nexeraanalysis, analysiscolumn, columnmin, minextraction, extractionsfc, sfcwithout, withoutpeaks, peaksmau, maumobile, mobilephase
Application Notebook - Solutions for Food Development
C10G-E060 Solutions for Food Development Application Notebook First Edition: March, 2018 © Shimadzu Corporation, 2018 Solutions for Food Development Index Application Notebook Facile quantitation of fundamental components Simultaneous Analysis of Water-Soluble Vitamins by Newly Developed "Shim-pack MAqC-ODS I" Column Newly…
Key words
allo, alloacid, acidthr, thranalysis, analysisdiacetyl, diacetylnews, newsile, ileamino, aminoflowrate, flowrateolive, olivevinegar, vinegarcolumn, columnbeverages, beveragesflesh, fleshyogurt
Spectrofluorophotometer RF-6000
Spectrofluorophotometer RF-6000
2025|Shimadzu|Brochures and specifications
C125-E009E Spectrofluorophotometer RF-6000 St ri v i n g f or t he Ultimate in Ac curac y and E a s y Oper ab ility The RF-6000 spectrofluorophotometer has been newly developed by combining Shimadzu’s long-cultivated expertise and cutting-edge…
Key words
fluorescence, fluorescencespectrofluorophotometer, spectrofluorophotometerquantum, quantumspectrum, spectrumcell, cellmeasurement, measurementexcitation, excitationintensity, intensitysphere, sphereefficiency, efficiencycorrection, correctionfluorescent, fluorescentintegrating, integratingyield, yieldholder
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike