Ultrafast Analysis of Water-Soluble Vitamins
Applications | 2011 | ShimadzuInstrumentation
Water-soluble vitamins play crucial roles in metabolism, cellular processes and public health. Rapid and reliable quantification of B-complex vitamins such as thiamine, riboflavin and niacin derivatives is essential in nutritional analysis, quality control of dietary supplements and functional food development. Advanced chromatographic techniques enable high throughput and precise determination of multiple vitamins in complex matrices.
This application demonstrates an ultrafast gradient elution method using a core-shell C18 column coupled with Nexera UHPLC for simultaneous separation of six water-soluble vitamins. Two workflows are presented: analysis of standard mixtures to assess repeatability and linearity, and practical testing on commercial nutrition drink samples to illustrate applicability in real matrices.
Key analytical parameters and instrumentation:
Standard mixture analysis of six vitamins (niacin, nicotinamide, pyridoxine, riboflavin phosphate, thiamine, riboflavin) yielded sharp peaks within 2.5 min. Repeatability (n=6) showed:
The ultrafast method offers:
Emerging directions include:
The presented ultrafast gradient LC method using a core-shell C18 column and Nexera system achieves precise, reproducible separation of six water-soluble vitamins in under 3 minutes. Its high throughput, accuracy and adaptability make it a valuable tool for nutritional analysis, quality control and research applications.
Shimadzu Corporation. Ultrafast Analysis of Water-Soluble Vitamins. Nexera Application Data Sheet No.16. Issued Mar 2011.
HPLC
IndustriesFood & Agriculture
ManufacturerShimadzu
Summary
Importance of the Topic
Water-soluble vitamins play crucial roles in metabolism, cellular processes and public health. Rapid and reliable quantification of B-complex vitamins such as thiamine, riboflavin and niacin derivatives is essential in nutritional analysis, quality control of dietary supplements and functional food development. Advanced chromatographic techniques enable high throughput and precise determination of multiple vitamins in complex matrices.
Aims and Study Overview
This application demonstrates an ultrafast gradient elution method using a core-shell C18 column coupled with Nexera UHPLC for simultaneous separation of six water-soluble vitamins. Two workflows are presented: analysis of standard mixtures to assess repeatability and linearity, and practical testing on commercial nutrition drink samples to illustrate applicability in real matrices.
Methodology and Instrumentation
Key analytical parameters and instrumentation:
- UHPLC System: Shimadzu Nexera with high-accuracy gradient capability
- Column: Phenomenex Kinetex C18, core-shell, 100 × 4.6 mm, 2.6 µm particles
- Mobile Phases: A = 20 mmol/L phosphate buffer (pH 2.5) with 2 mmol/L sodium 1-hexanesulfonate; B = A/ACN (2/3)
- Gradient: 5 % B at 0 min→23 % B at 1 min→100 % B at 2–2.5 min
- Flow Rate: 2.5 mL/min (180 µL mixer volume)
- Column Temperature: 40 °C
- Injection Volume: 5 µL for standards; 2–5 µL for sample tests
- Detection: UV at 275 nm, semi-micro flow cell
- Operating Pressure: Up to 48 MPa
Main Results and Discussion
Standard mixture analysis of six vitamins (niacin, nicotinamide, pyridoxine, riboflavin phosphate, thiamine, riboflavin) yielded sharp peaks within 2.5 min. Repeatability (n=6) showed:
- Retention time RSD ≤ 0.05 %
- Peak area RSD ≤ 0.10 %
Benefits and Practical Applications
The ultrafast method offers:
- High throughput: complete separation in under 3 minutes
- Excellent precision: low RSD in retention and peak area
- Broad applicability: suitable for standards and complex beverages
- Reduced solvent consumption: short gradient and core-shell efficiency
Future Trends and Application Possibilities
Emerging directions include:
- Integration with mass spectrometry for enhanced sensitivity and specificity
- Miniaturization and microfluidic platforms for on-site testing
- Automated sample preparation to further increase throughput
- Expansion to other vitamin classes and water-soluble biomarkers
Conclusion
The presented ultrafast gradient LC method using a core-shell C18 column and Nexera system achieves precise, reproducible separation of six water-soluble vitamins in under 3 minutes. Its high throughput, accuracy and adaptability make it a valuable tool for nutritional analysis, quality control and research applications.
Reference
Shimadzu Corporation. Ultrafast Analysis of Water-Soluble Vitamins. Nexera Application Data Sheet No.16. Issued Mar 2011.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Selective Quantitative Determination of Water Soluble Vitamins in Various Food Matrices Using the ACQUITY UPLC H-Class System and ACQUITY QDa Mass Detector
2014|Waters|Applications
[ APPLICATION NOTE ] Selective Quantitative Determination of Water Soluble Vitamins in Various Food Matrices Using the ACQUITY UPLC H-Class System and ACQUITY QDa Mass Detector Mark E. Benvenuti, Dimple Shah, and Jennifer A. Burgess Waters Corporation, Milford, MA, USA…
Key words
vitamins, vitaminsacquity, acquityvitamin, vitaminqda, qdasoluble, solublematrices, matricesselective, selectiveppb, ppbfood, foodresponse, responsewater, waterundiluted, undiluteduplc, uplcvarious, variousquantitative
Ultra-high Speed Analysis of Ibuprofen within USP <621> Allowed Limits by Nexera Method Scouting
2012|Shimadzu|Applications
High Performance Liquid Chromatography HPLC-009 Ultra-high Speed Analysis of Ibuprofen within USP <621> Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have been developed for effective analysis and productivity improvement. For HPLC, analysis using small particle…
Key words
ibuprofen, ibuprofenvalerophenone, valerophenonemau, maursd, rsdrelated, relatedods, odssymmetry, symmetryexamined, examinedspeed, speedallowed, allowedcompound, compoundsatisfies, satisfiesconformance, conformancesystem, systemanalysis
Shimadzu LCMS-2020
2021|Shimadzu|Brochures and specifications
C146-E121G Liquid Chromatograph Mass Spectrometer LCMS-2020 LCMS-2020 —Seeing is Believing. Ultra Fast UFswitching™ Rapid 15 msec Polarity Switching Ultra Fast UFsensitivity™ Superior Sensitivity with UHPLC Ultra Fast UFscanning™ 15,000 u/sec Fast Scanning Speed Speed is Power. Greater speed. Greater sensitivity.…
Key words
ufscanning, ufscanningultra, ultraufswitching, ufswitchingerythromycin, erythromycinpositive, positivedymuron, dymuronfast, fastcid, cidbrowser, browserswitching, switchingpurification, purificationnegative, negativeion, iondisplays, displaysdata
Ultra-High Speed Analysis of Ibuprofen by Nexera in Accordance with USP 621
2013|Shimadzu|Applications
LAAN-A-LC-E226 Application News L448 High Performance Liquid Chromatography Ultra-High Speed Analysis of Ibuprofen by Nexera in Accordance with USP 621 No. H i g h t h ro u g h p u t a n a l y s…
Key words
ibuprofen, ibuprofenvalerophenone, valerophenoneflowrate, flowratespeed, speedmau, mauusp, uspsuitability, suitabilityhigh, highcolumn, columnods, odsvalue, valuesubstances, substancespermitted, permittedsystem, systemrelated