Application compendium - Analysis of Polymers by GPC/SEC Energy & Chemical Applications
Guides | 2015 | Agilent TechnologiesInstrumentation
Polymer molecular size and distribution dictate key performance attributes such as strength, processability, and durability across industries from plastics to coatings. GPC/SEC delivers critical insight into polymer molecular weight distribution and polydispersity, guiding material design and quality assurance.
This compendium illustrates Agilent’s comprehensive GPC/SEC solutions applied to diverse polymer classes. Case studies highlight:
All studies employ gel permeation or size exclusion chromatography with tailored column chemistries and detector configurations. Key methodological elements include solvent selection (e.g. TCB, THF, HFIP, m-cresol, DMF, water), sample preparation protocols (heating, filtration, sample prep stations), and calibration strategies (polystyrene or universal calibration).
Highlights of analytical performance and findings:
Agilent GPC/SEC solutions offer:
Emerging directions include integration with automated sample prep, expansion of green solvent systems, advanced multi-detector workflows combining spectroscopic and rheological data, and AI-driven data analytics for deeper polymer structural insights.
Comprehensive GPC/SEC strategies spanning benign to aggressive solvents and room to high temperatures ensure accurate, reproducible molecular weight and structural characterizations across polymers. Agilent’s flexible platforms address the evolving needs of polymer science and industry.
GPC/SEC
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Significance of Polymer Characterization by GPC/SEC
Polymer molecular size and distribution dictate key performance attributes such as strength, processability, and durability across industries from plastics to coatings. GPC/SEC delivers critical insight into polymer molecular weight distribution and polydispersity, guiding material design and quality assurance.
Objectives and Overview
This compendium illustrates Agilent’s comprehensive GPC/SEC solutions applied to diverse polymer classes. Case studies highlight:
- High and low molecular weight polyolefins
- Engineering polymers (PEEK, PBT, PET, PPS)
- Elastomers and synthetic rubbers
- Resins and prepolymers
- Polar and challenging solvent systems
Methodology and Instrumentation
All studies employ gel permeation or size exclusion chromatography with tailored column chemistries and detector configurations. Key methodological elements include solvent selection (e.g. TCB, THF, HFIP, m-cresol, DMF, water), sample preparation protocols (heating, filtration, sample prep stations), and calibration strategies (polystyrene or universal calibration).
- Systems: Agilent 1260 Infinity, PL-GPC 220 High-Temperature, 1260 Infinity Multi-Detector, PL-GPC 50 Integrated GPC/SEC
- Columns: PLgel Olexis, MIXED-B/C/D, MesoPore, ResiPore, OligoPore, PolarGel, PlusPore
- Detectors: Refractive index, UV, viscometer, multi-angle light scattering (15°/90°)
Main Results and Discussion
Highlights of analytical performance and findings:
- PLgel Olexis resolves true multimodal molecular weight distributions in polyolefins without column dislocations.
- Molecular weight repeatability in HDPE achieves <1% variation using high-temperature GPC.
- Light scattering detection accurately characterizes high-MW guar gum where RI alone underestimates size.
- High-temperature systems enable analysis of PEEK, PPS, and nylon in aggressive solvents at 160–210 °C.
- Viscometry and universal calibration reveal branching in polyethylene and complex polymer architectures.
- Analytical to preparative scale fractionation of epoxy oligomers on OligoPore columns isolates pure components.
- PolarGel columns enable stable separations in polar solvents (DMF, DMAc, water) for phenolics, polyamides, and polyurethanes.
Benefits and Practical Applications
Agilent GPC/SEC solutions offer:
- Reliable molecular weight profiling for research, catalyst evaluation, and process optimization.
- Adaptable column and detector options to address solubility, temperature, and solvent challenges.
- High throughput and robust performance for QC in polymer manufacturing.
- Preparative capabilities to isolate oligomer fractions for formulation or further study.
Future Trends and Potential Applications
Emerging directions include integration with automated sample prep, expansion of green solvent systems, advanced multi-detector workflows combining spectroscopic and rheological data, and AI-driven data analytics for deeper polymer structural insights.
Conclusion
Comprehensive GPC/SEC strategies spanning benign to aggressive solvents and room to high temperatures ensure accurate, reproducible molecular weight and structural characterizations across polymers. Agilent’s flexible platforms address the evolving needs of polymer science and industry.
References
- H. Coll, D. K. Giddings. J. Polym. Sci. 8, 89 (1970).
- T. G. Scholte et al. J. Appl. Polym. Sci. 29, 3763 (1984).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of food by gpc/sec - Application compendium
2015|Agilent Technologies|Guides
Application compendium Analysis of food by gpc/sec Verified for Agilent 1260 Infinity GPC/SEC System Analysis of food by GPC/SEC Contents Application compendium Introduction3 Food additives4 Pectins5 Carboxymethyl cellulose 7 Starch8 Corn flour 10 Pullulan and dextran 12 Gelatin14 Gums15 Flavorings16…
Key words
gpc, gpclog, logmolecular, molecularsec, secweight, weightpolymers, polymerspolyolefins, polyolefinspolysaccharides, polysaccharidespolyamides, polyamideswaxes, waxespolyesters, polyestersviscometer, viscometerrubbers, rubbersstyreneacrylonitrile, styreneacrylonitrilescattering
AGILENT ORGANIC GPC/SEC COLUMNS
2017|Agilent Technologies|Brochures and specifications
AGILENT ORGANIC GPC/SEC COLUMNS Contents PLgel GPC columns�����������������������������������������������������������������������������������������������������������������������������������������������3 InfinityLab PlusPore columns������������������������������������������������������������������������������������������������������������������������������5 InfinityLab PolyPore�������������������������������������������������������������������������������������������������������������������������������������������6 InfinityLab ResiPore�������������������������������������������������������������������������������������������������������������������������������������������7 InfinityLab MesoPore�����������������������������������������������������������������������������������������������������������������������������������������8 InfinityLab OligoPore������������������������������������������������������������������������������������������������������������������������������������������9 PL Rapide columns����������������������������������������������������������������������������������������������������������������������������������������������10 Narrow Bore columns�����������������������������������������������������������������������������������������������������������������������������������������11 InfinityLab PLgel Olexis��������������������������������������������������������������������������������������������������������������������������������������12 PLgel MIXED columns����������������������������������������������������������������������������������������������������������������������������������������13 PLgel 20 µm MIXED-A�������������������������������������������������������������������������������������������������������������������������������������14 PLgel 10 µm MIXED-B�������������������������������������������������������������������������������������������������������������������������������������15 PLgel…
Key words
gpc, gpcplgel, plgelinfinitylab, infinitylabthf, thfcolumns, columnsordering, orderingpolymers, polymerssec, secconditions, conditionsresolution, resolutiondescription, descriptionpore, porehigh, highcharacteristics, characteristicsmolecular
AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS
2018|Agilent Technologies|Brochures and specifications
AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS Contents Agilent GPC/SEC columns�����������������������������������������������������������������������������������������������������������������������������������3 InfinityLab PL Multisolvent����������������������������������������������������������������������������������������������������������������������������������4 PL aquagel-OH SEC columns�������������������������������������������������������������������������������������������������������������������������������7 PL Rapide Aqua columns�����������������������������������������������������������������������������������������������������������������������������������10 PL aquagel-OH preparative SEC columns�������������������������������������������������������������������������������������������������������11 Agilent PolarGel GPC columns��������������������������������������������������������������������������������������������������������������������������12 Agilent Publications��������������������������������������������������������������������������������������������������������������������������������������������14 Agilent GPC/SEC Analysis Systems����������������������������������������������������������������������������������������������������������������15 1976 PLgel columns, individual…
Key words
gpc, gpcsec, secaquagel, aquagelcolumns, columnspolargel, polargelmol, molmultisolvent, multisolventpolymers, polymersinfinitylab, infinitylabpolar, polarordering, orderingagilent, agilentretention, retentionsolvents, solventstime
Analysis of Polybutadienes by GPC with Triple Detection
2015|Agilent Technologies|Applications
Analysis of Polybutadienes by GPC with Triple Detection Application Note Materials Testing & Research Author Introduction Graham Cleaver Polybutadienes are a type of synthetic rubber, commonly used to make tires along with other car parts such as belts, hoses and…
Key words
polybutadiene, polybutadienescattering, scatteringlog, loglight, lightangle, anglerefractive, refractivegpc, gpchouwink, houwinkextrapolated, extrapolatedviscometry, viscometrydistribution, distributionrubber, rubberrely, relysystem, systemmark