LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology

Applications | 2017 | WatersInstrumentation
LC/MS, LC/MS/MS, LC/QQQ, 2D-LC
Industries
Forensics
Manufacturer
Waters

Summary

Importance of the Topic


Forensic toxicology requires rapid, sensitive and robust analytical workflows to reliably detect a broad range of illicit drugs in complex biological fluids such as urine. Achieving sub-ppb detection limits while minimizing sample preparation time is critical for legal casework, workplace drug testing and clinical toxicology. Advances in multi-dimensional liquid chromatography coupled with tandem mass spectrometry (2D LC-MS/MS) offer a path to streamline extraction and enhance separation performance.

Objectives and Study Overview


This study aimed to develop and validate a fast, automated micro-extraction protocol combined with 2D LC-MS/MS screening for twelve common illicit drugs in human urine. Key goals included reducing sample prep to under 20 minutes, achieving a 100 ppt detection limit, and demonstrating enhanced signal and reduced interferences relative to conventional single-dimension methods.

Methodology and Instrumentation


  • Sample Preparation: A reversed-phase/ion-exchange SPE protocol was optimized, including protein precipitation with acetonitrile, dilution in water and sequential cartridge conditioning, washing and elution steps without evaporation.
  • Chromatography: Waters ACQUITY UPLC with 2D Technology in “trap and elute” configuration and at-column dilution was used. A BEH C18 analytical column was paired with water/acetonitrile mobile phases containing 0.5% formic acid, employing a 10 min gradient.
  • Mass Spectrometry: Waters Xevo TQD triple quadrupole in positive ESI mode. Two MRM transitions were monitored per analyte for quantification and confirmation, with optimized cone and collision energies.

Main Results and Discussion


Automated method development screened 36 chromatographic permutations across trap chemistries, loading pH values and elution solvents in an overnight run. Organic extracts (MeOH, ACN) consistently delivered 2–10× higher signals compared to aqueous injections due to disrupted glass vial ion-exchange. Final methods split the analytes into two 2D LC runs based on retention behavior. The optimized micro-extraction protocol achieved average recoveries of ~90% for the twelve drugs in urine, with quantitation limits of 100 ppt and several detection signals down to 10 ppt. Trace-level interferences were minimized using RP/ion-exchange SPE and 2D chromatography.

Benefits and Practical Applications


  • Rapid sample prep in under 20 min without evaporation or reconstitution
  • High sensitivity (100 ppt LOD; some analytes at 10 ppt)
  • Enhanced separation integrity and reduced matrix interferences via 2D LC
  • Automated optimization reduces development time from days to hours
  • Applicable to forensic, clinical, workplace and anti-doping testing

Future Trends and Potential Applications


Further integration of online SPE and 2D LC modules will enable fully automated sample-to-report workflows. Expansion to high-resolution MS detection, additional matrices (blood, oral fluid) and broader drug panels will extend applicability. Machine-learning-driven method optimization and microfluidic SPE cartridges promise further gains in speed, sensitivity and throughput.

Conclusion


This work demonstrates that coupling a rapid micro-extraction protocol with automated 2D LC-MS/MS yields a high-throughput, highly sensitive assay for multi-residue illicit drug analysis in urine. The strategy achieves sub-ppb detection, robust reproducibility and minimal sample handling, meeting the rigorous demands of forensic toxicology.

Used Instrumentation


  • Waters ACQUITY UPLC System with 2D Technology (trap and elute, at-column dilution)
  • Waters Xevo TQD Triple Quadrupole Mass Spectrometer
  • Oasis HLB and MCX SPE cartridges
  • BEH C18 analytical column, 2.1×50 mm, 1.7 μm

References


  1. Mallet CR. Analysis of Pharmaceuticals and Pesticides in Bottled, Tap, and Surface Water using ACQUITY UPLC with 2D Technology. Waters Corporation Technical Report 720005176EN; 2014.
  2. Mallet CR. Multi-Dimensional Chromatography Compendium: Trap and Elute vs At-Column Dilution. Waters Corporation Technical Report 720005339EN; 2015.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of Synthetic Cannabinoids in Urine, Plasma, and Edibles  Using Multidimensional UPLC Technology
[ APPLICATION NOTE ] Analysis of Synthetic Cannabinoids in Urine, Plasma, and Edibles Using Multidimensional UPLC Technology Kayla Benvenuto MS, 1 Sabra R. Botch-Jones MS, MA, D-ABFT,1 Claude R. Mallet PhD 2 1 Boston University School of Medicine, Boston, MA,…
Key words
loq, loqmeoh, meohext, extquadratric, quadratricacn, acnelute, elutehlb, hlbedible, ediblequadratic, quadraticmcx, mcxmax, maxurine, urineratio, ratioion, ionesi
Analysis of Ketamine and Xylazine in Rat Tissues Using the  ACQUITY UPLC with 2D Technology
[ APPLICATION NOTE ] Analysis of Ketamine and Xylazine in Rat Tissues Using the ACQUITY UPLC with 2D Technology Malorie Mella, 2 Brendan Schweitzer,1 Sabra R. Botch-Jones, M.S., M.A,1 Claude R. Mallet, Ph.D. 2 Boston University School of Medicine,1 Boston,…
Key words
xylazine, xylazinerat, ratketamine, ketaminedtl, dtlcalf, calfhlb, hlbacn, acntic, ticliver, liverspleen, spleenelution, elutionkidney, kidneybrain, brainheart, hearttime
Novel Extraction Techniques Using ACQUITY UPLC with 2D Technology: Part IV – First Time Users
[ APPLICATION NOTE ] Novel Extraction Techniques Using ACQUITY UPLC with 2D Technology: Part IV – First Time Users Kylie Bartram,1 Michaela Federico, 1 Jenna Gardner,1 Olivia George,1 Hajin Hwang, 1 Miranda Shaine, 1 Sabra R. Botch-Jones MS, MA, D-ABFT,1…
Key words
pinaca, pinacatic, ticlincomycin, lincomycinclindamycin, clindamycindirithromycin, dirithromycintail, tailhlb, hlberythromycin, erythromycinspike, spikerec, recclarithromycin, clarithromycinmeoh, meohnote, noteapplication, applicationunextracted
Analysis of Pharmaceuticals and Pesticides in Bottled, Tap, and Surface Water Using ACQUITY UPLC Systems with 2D-LC Technology
Analysis of Pharmaceuticals and Pesticides in Bottled, Tap, and Surface Water Using ACQUITY UPLC Systems with 2D-LC Technology Claude Mallet Workflow Integration Group, Separations Technologies, Waters Corporation, Milford, MA, USA A P P L I C AT I O N…
Key words
tic, ticmcx, mcxtripolidine, tripolidineesi, esimax, maxatrazine, atrazineelute, elutecimetidine, cimetidinecarbamazepine, carbamazepineneutral, neutralcorticosterone, corticosteronewash, washdiethylcarbamazine, diethylcarbamazinebromhexine, bromhexinetrimethoprim
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike