METHOD DEVELOPMENT - The Path to Successful Drug Development Starts with Purposeful Method Development
Guides | 2014 | WatersInstrumentation
Reliable and reproducible chromatographic methods play a critical role in pharmaceutical development, quality control, and regulatory compliance. A systematic, data-driven approach to method development accelerates discovery and lowers costs by reducing trial-and-error iterations. Integration of advanced UltraPerformance LC technology, combined detectors, and flexible software enables laboratories to build robust methods that deliver high resolution, sensitivity, and throughput, while ensuring long-term performance and method transferability.
The primary goals are to showcase a structured protocol for method development using UPLC H-Class systems, to exploit UV and mass detection for peak tracking and confirmation, and to illustrate how custom data-processing tools streamline decision making. Case studies include:
Key components of the workflow:
A multistage screening protocol delivered robust separations in hours rather than weeks:
Adopting this integrated approach yields multiple advantages for laboratories:
Continued advancements will focus on digitalization, automation, and predictive analytics:
By combining UPLC H-Class automation, orthogonal detection modes, and advanced software, laboratories can develop highly robust and transferable methods efficiently. This systematic framework reduces development time, improves data quality, and prepares organizations for future analytical challenges.
1. Berthelette KD, Summers M, Fountain KJ. Ensuring Data Quality by Benchmarking System Performance Using Waters Neutrals Quality Control Reference Material. Waters Application Note 2013, Part Number 720004622EN.
2. Jones MD, Alden P, Fountain KJ, Aubin A. Implementation of Methods Translation between Liquid Chromatography Instrumentation. Waters Application Note 2010, Part Number 720003721EN.
3. Summers M, Fountain KJ. A Quality by Design Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone. Waters Application Note 2011, Part Number 720004072EN.
Consumables, Software, HPLC, LC/MS, LC columns, LC/SQ
IndustriesPharma & Biopharma
ManufacturerWaters
Summary
Importance of Topic
Reliable and reproducible chromatographic methods play a critical role in pharmaceutical development, quality control, and regulatory compliance. A systematic, data-driven approach to method development accelerates discovery and lowers costs by reducing trial-and-error iterations. Integration of advanced UltraPerformance LC technology, combined detectors, and flexible software enables laboratories to build robust methods that deliver high resolution, sensitivity, and throughput, while ensuring long-term performance and method transferability.
Objectives and Study Overview
The primary goals are to showcase a structured protocol for method development using UPLC H-Class systems, to exploit UV and mass detection for peak tracking and confirmation, and to illustrate how custom data-processing tools streamline decision making. Case studies include:
- Metoclopramide and related substances assay using systematic pH, stationary phase, and solvent screening
- Ziprasidone forced-degradation method development with combined UV/MS detection and QbD optimization
- System performance benchmarking with a neutral reference standard to ensure data quality
Methodology and Instrumentation
Key components of the workflow:
- Waters ACQUITY UPLC H-Class System with Column Manager, Solvent Select Valve, and Auto•Blend Plus Technology
- Detectors: ACQUITY UPLC PDA for UV spectral data; ACQUITY QDa for rapid MS confirmation
- Column chemistries screened: BEH C18, CSH C18, Phenyl-Hexyl, HSS PFP, and HILIC phases
- Software tools: Empower Chromatography Data Software for custom calculations, scoring, and method validation; Fusion AE for QbD design of experiments
Main Results and Discussion
A multistage screening protocol delivered robust separations in hours rather than weeks:
- Rapid scouting of mobile phase pH identified optimal retention conditions for basic analytes
- Column screening with acetonitrile versus methanol highlighted selectivity differences among C18, phenyl, and PFP phases
- Gradient slope, column temperature, and pH optimization improved resolution and peak shape quantitatively, guided by Empower scoring reports
- Mass tracking with the QDa detector confirmed analyte identity and exposed coelutions in real time, reducing standard injections
Benefits and Practical Applications
Adopting this integrated approach yields multiple advantages for laboratories:
- Faster method development cycles with high-confidence results
- Automated data processing and unbiased scoring eliminate user variability
- Built-in robustness through QbD design and system benchmarking reduces revalidation risk
- Simplified method transfer between UPLC and HPLC platforms facilitates global implementation
Future Trends and Applications
Continued advancements will focus on digitalization, automation, and predictive analytics:
- Deep integration of machine learning to predict optimal chromatographic conditions
- Cloud-based method libraries enabling global standardization and rapid sharing
- Enhanced high-throughput screening for complex biological matrices and real-time quality monitoring
- Seamless coupling of UPLC with next-generation detectors for multi-attribute analysis in biopharma
Conclusion
By combining UPLC H-Class automation, orthogonal detection modes, and advanced software, laboratories can develop highly robust and transferable methods efficiently. This systematic framework reduces development time, improves data quality, and prepares organizations for future analytical challenges.
References
1. Berthelette KD, Summers M, Fountain KJ. Ensuring Data Quality by Benchmarking System Performance Using Waters Neutrals Quality Control Reference Material. Waters Application Note 2013, Part Number 720004622EN.
2. Jones MD, Alden P, Fountain KJ, Aubin A. Implementation of Methods Translation between Liquid Chromatography Instrumentation. Waters Application Note 2010, Part Number 720003721EN.
3. Summers M, Fountain KJ. A Quality by Design Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone. Waters Application Note 2011, Part Number 720004072EN.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
APPLICATION NOTEBOOK - IMPURITIES - Developing Safe and Effective Drugs
2016|Waters|Guides
[ APPLICATION NOTEBOOK ] IMPURITIES Developing Safe and Effective Drugs INT RODUCTION NAVIGATION T he pharmaceutical industry is integral in maintaining public health by providing therapeutic and preventative medicines. T he cornerstones of bringing new medicines to market are quality,…
Key words
home, homeuplc, uplcimpurities, impuritiesziprasidone, ziprasidoneusp, uspacquity, acquityimpurity, impuritymethod, methodtioconazole, tioconazoleminutes, minutessimvastatin, simvastatinhplc, hplcusing, usingrelated, relatedanalysis
Rapid Method Development through Proper Column Selection
2012|Waters|Applications
Rapid Method Development through Proper Column Selection Mia Summers and Kenneth J. Fountain Waters Corporation, 34 Maple Street, Milford, MA, USA A P P L I C AT I O N B E N E F I T S ■■…
Key words
hss, hsscolumn, columncyano, cyanoproper, properselection, selectionchemistries, chemistriesfluoro, fluorocsh, cshdevelopment, developmentphenyl, phenylpfp, pfpuplc, uplcrapid, rapidacquity, acquityselectivity
Improving Effectiveness in Method Development by Using a Systematic Screening Protocol
2014|Waters|Technical notes
Improving Effectiveness in Method Development by Using a Systematic Screening Protocol Margaret Maziarz, Sean M. McCarthy, and Mark Wrona Waters Corporation, Milford, MA, USA A P P L I C AT I O N B E N E F I…
Key words
acquity, acquityuplc, uplcsystematic, systematicprotocol, protocoleffectiveness, effectivenessdevelopment, developmentscreening, screeningimproving, improvingqda, qdamethod, methodusing, usinghss, hsscortecs, cortecscsh, cshscouting
Transfer of Two USP Compendial Methods for Impurities of Ziprasidone HCL to a Single UPLC Method
2013|Waters|Applications
Transfer of Two USP Compendial Methods for Impurities of Ziprasidone HCL to a Single UPLC Method Margaret Maziarz, Michael D. Jones, Warren B. Potts, and Frederic Forini Waters Corporation, Milford, MA, USA A P P L I C AT I…
Key words
ziprasidone, ziprasidoneuplc, uplccompendial, compendialhcl, hclrelated, relatedusp, uspimpurities, impuritiescompound, compoundeluting, elutingmethod, methodsuitability, suitabilitylate, latetransfer, transfermethods, methodsearly