Accurately Quantify 380 Pesticides Using LC-MS/MS and GC-MS/MS
Brochures and specifications | 2016 | RestekInstrumentation
Reliable measurement of pesticide residues in food and environmental samples is critical for regulatory compliance, consumer safety, and international trade. Certified reference materials (CRMs) for multiresidue pesticide analysis provide traceable standards that streamline method development, validation, and routine quality control in both LC-MS/MS and GC-MS/MS workflows.
This application note presents two comprehensive CRM kits from Restek: one for quantitative LC-MS/MS analysis of 204 pesticides and another for GC-MS/MS analysis of 203 pesticides. Each kit is formulated to maximize long-term stability, grouping compounds by chemical class to minimize degradation and ensure reliable results across diverse matrices.
Both kits include 1 mL ampuls of mixed standards at 100 µg/mL (or 106–120 µg/mL for LC formulations), grouped into multiple mixes by functionality (e.g., organophosphorus, carbamates, pyrethroids). Detailed chromatographic methods and transition tables are provided as downloadable XLS files. Instrumentation and consumables described include:
Extensive QC testing confirmed each mix’s nominal concentration and long-term stability when stored and handled properly. Chromatograms (Figures 1–19) demonstrate baseline separation and consistent retention times on both LC and GC platforms. Grouping by chemical class reduced inter-compound interactions, enabling accurate quantification even in complex matrices.
Advances in high-throughput sample preparation and integration of automated platforms will further streamline multiresidue analysis. Expanding CRM coverage to emerging contaminants, isotopically labeled standards for matrix compensation, and miniaturized column formats will support next-generation regulatory demands and environmental monitoring programs.
Restek’s multiresidue pesticide CRM kits deliver robust, ISO-compliant standards for both LC-MS/MS and GC-MS/MS workflows. Their stability, comprehensive documentation, and compatibility with established QuEChERS and chromatographic methods make them indispensable tools for accurate pesticide residue analysis.
LC-MS/MS, GC-MS/MS, Ultra Aqueous C18 columns, Rxi®-5ms columns, QuEChERS salts and dSPE tubes, SINGLE StEP® filter vials, Restek Leak Detector, ProFLOW 6000 flowmeter.
GC/MSD, GC/MS/MS, Consumables, LC/MS, LC/MS/MS
IndustriesEnvironmental, Food & Agriculture
ManufacturerRestek
Summary
Significance of the Topic
Reliable measurement of pesticide residues in food and environmental samples is critical for regulatory compliance, consumer safety, and international trade. Certified reference materials (CRMs) for multiresidue pesticide analysis provide traceable standards that streamline method development, validation, and routine quality control in both LC-MS/MS and GC-MS/MS workflows.
Objectives and Study Overview
This application note presents two comprehensive CRM kits from Restek: one for quantitative LC-MS/MS analysis of 204 pesticides and another for GC-MS/MS analysis of 203 pesticides. Each kit is formulated to maximize long-term stability, grouping compounds by chemical class to minimize degradation and ensure reliable results across diverse matrices.
Methodology and Instrumentation
Both kits include 1 mL ampuls of mixed standards at 100 µg/mL (or 106–120 µg/mL for LC formulations), grouped into multiple mixes by functionality (e.g., organophosphorus, carbamates, pyrethroids). Detailed chromatographic methods and transition tables are provided as downloadable XLS files. Instrumentation and consumables described include:
- LC-MS/MS system equipped with Ultra Aqueous C18 columns (3 µm and 5 µm, 2.1–4.6 mm ID) for optimized resolution of 204 analytes.
- GC-MS/MS system paired with Rxi®-5ms fused-silica columns (0.18–1.50 µm df, 0.18–0.53 mm ID) for 203 analyte separations.
- QuEChERS extraction salts and dSPE cleanup tubes for efficient sample preparation according to original, AOAC 2007.01, and EN 15662 protocols.
- Thomson SINGLE StEP® filter vials for rapid particulate removal, and supporting accessories.
- Leak detection and flow measurement tools (Restek Leak Detector and ProFLOW 6000) to ensure instrument integrity and accurate carrier gas flows.
Main Results and Discussion
Extensive QC testing confirmed each mix’s nominal concentration and long-term stability when stored and handled properly. Chromatograms (Figures 1–19) demonstrate baseline separation and consistent retention times on both LC and GC platforms. Grouping by chemical class reduced inter-compound interactions, enabling accurate quantification even in complex matrices.
Benefits and Practical Applications
- Rapid method setup: pre-mixed standards eliminate time-consuming preparation steps.
- Enhanced accuracy: certified concentrations support compliance with ISO and regulatory requirements.
- Versatile workflows: kits support a wide range of food, environmental, and agricultural sample types.
- Cost savings: reduced waste, fewer trial runs, and minimized downtime during method validation.
Future Trends and Possibilities
Advances in high-throughput sample preparation and integration of automated platforms will further streamline multiresidue analysis. Expanding CRM coverage to emerging contaminants, isotopically labeled standards for matrix compensation, and miniaturized column formats will support next-generation regulatory demands and environmental monitoring programs.
Conclusion
Restek’s multiresidue pesticide CRM kits deliver robust, ISO-compliant standards for both LC-MS/MS and GC-MS/MS workflows. Their stability, comprehensive documentation, and compatibility with established QuEChERS and chromatographic methods make them indispensable tools for accurate pesticide residue analysis.
Instrumentation
LC-MS/MS, GC-MS/MS, Ultra Aqueous C18 columns, Rxi®-5ms columns, QuEChERS salts and dSPE tubes, SINGLE StEP® filter vials, Restek Leak Detector, ProFLOW 6000 flowmeter.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Diagnosing and Preventing High Back Pressure in LC Systems
2018|Restek|Guides
Restek LC Accessories Diagnosing and Preventing High Back Pressure in LC Systems www.restek.com//LCacc Diagnosing and Preventing High Back Pressure in LC Systems High pressure. It’s a fact of life for HPLC and UHPLC analyses. The force that is necessary to…
Key words
cap, capslit, slitexp, expraptor, raptorguard, guardpre, prerestek, restekkit, kitpink, pinkblue, bluefilter, filtergreen, greenred, reddescription, descriptionpolyvinyldifluoride
RESTEK LC Columns and Accessories
2019|Restek|Brochures and specifications
LC Columns and Accessories www.restek.com/lc This is Restek LC Restek has been perfecting the art and science of liquid chromatography (LC) for more than a quarter-century. Over that time, the burdens placed on LC systems and analysts have changed dramatically,…
Key words
raptor, raptorexp, expdescription, descriptionsimilar, similarguard, guardfluorophenyl, fluorophenylfilter, filterrestek, restekpart, partpeek, peekspp, spproc, rocmin, minhand, handferrule
2019/2021 Chromatography Consumables Catalog
2019|Thermo Fisher Scientific|Brochures and specifications
Connected chromatography solutions 2019/2021 Chromatography Consumables Catalog The collective power of chromatography Expect reproducible results with sample prep, columns and vials Maximizing your chromatography productivity and achieving reproducible results requires optimizing the whole workflow from sample to knowledge. By choosing…
Key words
clear, clearptfe, ptfequantity, quantitysilicone, siliconecolumns, columnsred, redpolypropylene, polypropylenelength, lengthyes, yescolumn, columnwhite, whiteamber, amberhplc, hplcflat, flatsize
CANNABIS TESTING LC/GC/SFC/SPE/QuEChERS
|Phenomenex|Guides
CANNABIS TESTING LC/GC/SFC/SPE/QuEChERS Analytical Options For Your Laboratory Needs www.phenomenex.com/cannabis If Phenomenex products in this guide do not provide at least an equivalent separation as compared to other products of the same phase and dimensions, return the product with comparative…
Key words
phenomenex, phenomenexsecurityguard, securityguardcartridges, cartridgespacket, packetphases, phasesstrata, stratashell, shellcellulose, celluloseoriginald, originaldunit, unitphenex, phenextop, topcannabis, cannabisguard, guardcbg