Significance of the Topic


Alkylphenols are widely present in the environment as raw materials or degradation products of industrial chemicals. Certain alkylphenols are suspected endocrine disruptors, making their accurate detection and quantification critical for environmental monitoring and public health protection.

Objectives and Overview


This study outlines a liquid chromatography–mass spectrometry method for simultaneous analysis of bisphenol A and a series of alkylphenols with side chains from C4 to C9. The goal was to achieve clear separation, precise identification, and reliable quantification at low parts-per-billion concentrations.

Methodology and Instrumentation


The analysis employed reversed-phase LC separation on a VP-ODS column with a water-methanol gradient. Detection was performed using negative ion atmospheric pressure chemical ionization LC-MS in both full scan and selected ion monitoring modes. Key instrument parameters included a 0.2 mL/min flow rate, 10 µL injection volume, and APCI probe temperatures of up to 400 °C.

Instrumentation Used

  • Shimadzu LC-MS system with APCI negative mode
  • VP-ODS column (2.0 mm I.D. x 150 mm)
  • Mobile phases water (A) and methanol (B) with gradient from 20 to 90 percent B
  • APCI probe voltage -3.0 kV, probe temperature 400 °C, CDL 200 °C
  • Scan range m/z 50–600 in full scan; SIM for target masses

Main Results and Discussion


Full scan mass chromatograms enabled clear identification of deprotonated alkylphenol molecules and bisphenol A. SIM analysis at 10 ppb demonstrated distinct peaks for each homolog. Calibration curves over 10–1000 ppb showed excellent linearity with correlation coefficients above 0.9995 for all compounds, confirming high accuracy and reproducibility.

Benefits and Practical Applications


The described LC-MS method offers high sensitivity and selectivity for environmental monitoring of alkylphenols and bisphenol A. It supports regulatory compliance testing, water quality assessment, and research on endocrine-disrupting chemicals.

Future Trends and Potential Applications


Advancements may include integration with high-resolution mass analyzers to improve compound identification, miniaturized LC-MS systems for in-field analysis, and expansion to other phenolic environmental contaminants. Automation of sample preparation and data processing will further enhance throughput.

Conclusion


This LC-MS application provides a robust framework for accurate detection and quantification of C4–C9 alkylphenols and bisphenol A in environmental samples. Its demonstrated linearity, sensitivity, and reproducibility make it suitable for routine monitoring and research.

References

  • Shimadzu LC-MS Application Data Sheet No. 037
  • Dr. Shigeru Suzuki, Kawasaki Municipal Research Institute for Environmental Protection

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of Bisphenol A and Nonylphenol using LC-MS
LC-MS Application Data Sheet No. 032 Analysis of Bisphenol A and Nonylphenol using LC-MS exogenous endocrine disrupter compounds. These phenols are generally derivatized using trimethylsilyl (TMS) reagent before analysis by GC-MS. However, this data sheet introduces the direct analysis of…
Key words
bisphenol, bisphenolnonylphenol, nonylphenolcdl, cdlsheet, sheetconc, concvoltage, voltagetemperature, temperaturearray, arrayprobe, probemean, meantrimethylsilyl, trimethylsilylmarketing, marketingmin, mintms, tmsphenols
Analysis of Anionic Surfactants using LC-MS
LC-MS Application Data Sheet No. 042 Analysis of Anionic Surfactants using LC-MS analysis of the anionic surfactant alkyl phenyl polyoxyethylene sulfonate. The mass chromatogram and mass spectrum of the alkyl phenyl polyoxyethylene sulfonate are shown in Figs.1 and Fig.2 respectively.…
Key words
ona, onacdl, cdlsurfactants, surfactantsanionic, anionicalkyl, alkylvoltage, voltagearray, arrayprobe, probetemperature, temperaturemarketing, marketingdomestic, domesticarising, arisingmass, masssurfactant, surfactantconcerns
Analysis of Bisphenol A Diglycidyl Ether Using LC-MS
LC-MS Application Data Sheet No. 046 Analysis of Bisphenol A Diglycidyl Ether Using LC-MS Bisphenol A diglycidyl ether (BADGE) (Fig.1), formed by a condensation reaction (glycidyl reaction) between bisphenol A and epichlorohydrin, is widely used as a raw material of…
Key words
bisphenol, bisphenolbadge, badgecdl, cdlvoltage, voltagecoating, coatingresin, resindiglycidyl, diglycidylarray, arrayglycidyl, glycidylreaction, reactionelution, elutionleaching, leachingtemperature, temperatureepoxy, epoxymarketing
Analysis of golf course pesticides using LC-MS
LC-MS Application Data Sheet No. 033 Analysis of golf course pesticides using LC-MS Many types of pesticides are applied to keep golf courses green. While less pesticide is used on golf courses than on agricultural land, the proximity of Japanese…
Key words
golf, golfthiram, thiramasulam, asulampesticides, pesticidesconc, conccdl, cdlsheet, sheetvoltage, voltageconh, conharray, arraybensulide, bensulidetriclopyr, triclopyrmcpp, mcppcourses, coursespencycuron
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike