Optimize the Agilent 1260 Infi nity Analytical SFC Solution with the Agilent 1290 Infi nity ELSD

Technical notes | 2014 | Agilent TechnologiesInstrumentation
SFC
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the topic


Supercritical fluid chromatography (SFC) offers significant advantages over traditional HPLC, including lower mobile phase viscosity, improved diffusion and mass transfer, and faster separations at reduced backpressures. Coupling SFC with evaporative light scattering detection (ELSD) extends the application scope to non–UV-active and thermally stable compounds, enhancing analytical capabilities in pharmaceutical, food, and chemical analysis.

Objectives and overview


This study outlines an optimized configuration of the Agilent 1260 Infinity Analytical SFC Solution combined with the Agilent 1290 Infinity ELSD detector. It investigates the effects of preheating the SFC effluent and introducing a make-up flow on ELSD signal quality, aiming to identify optimal operating parameters for peak intensity, area, and reproducibility.

Methodology and instrumentation


An Agilent 1260 Infinity SFC system was connected to a 1290 Infinity ELSD via a custom splitter assembly. Key steps included preheating the split effluent in a secondary thermostatted column compartment (TCC) using a stainless steel capillary heat exchanger (internal volumes: 1.8, 3, and 6 µL) and adjusting a methanol make-up flow from an isocratic pump.

  • Agilent 1260 Infinity Analytical SFC Solution (G4309A) with binary pump, degasser, thermostatted column compartment, DAD, isocratic pump, standard autosampler, and backpressure regulator.
  • Agilent 1290 Infinity thermostatted column compartment and evaporative light scattering detector (G4261B).
  • Agilent OpenLAB CDS ChemStation software.

Main results and discussion


Preheating the SFC effluent at 30 °C provided maximum ELSD response, improving peak area and height by up to 20 % compared to a direct connection. Preheating above 30 °C led to decreased signal and increased variability. A 3 µL heat exchanger volume was chosen for optimal throughput. Introducing a make-up flow (0.2 mL/min methanol) reduced relative standard deviations (area RSD ~5 %, height RSD ~4–6 %) without compromising signal-to-noise. Higher make-up flows diluted the analyte stream and degraded S/N ratios.

Benefits and practical applications


The optimized SFC-ELSD configuration delivers enhanced sensitivity and reproducibility for non-chromophoric compounds, facilitating robust quantitation in pharmaceutical quality control, lipid analysis, and natural product characterization. The modular setup allows flexible temperature control and flow splitting for diverse sample matrices.

Future trends and possibilities


Emerging developments may include integration with mass spectrometry for compound identification, automated preheating control, and miniaturized heat exchangers for reduced dead volume. Further exploration of alternative make-up solvents and dynamic pressure management could extend SFC-ELSD performance to polar and high-molecular-weight analytes.

Conclusion


Combining the Agilent 1260 Infinity SFC and 1290 Infinity ELSD with a pre-split heat exchanger at 30 °C and a 0.2 mL/min methanol make-up flow yields optimal signal intensity, precision, and S/N for a range of analytes. This configuration enhances the reliability and applicability of SFC-ELSD in routine and research laboratories.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Optimize the Agilent 1260 Infi nity Analytical SFC Solution with the Agilent 6150 Single Quadrupole MS
Optimize the Agilent 1260 Infinity Analytical SFC Solution with the Agilent 6150 Single Quadrupole MS Technical Overview Author Abstract Edgar Naegele This Technical Overview gives a detailed description of an optimized configuration Agilent Technologies, Inc. of an SFC instrument with…
Key words
flow, flowsfc, sfcpreheating, preheatingeffluent, effluentmake, makeinfluence, influenceversus, versusheight, heightsplitter, splitterconnection, connectionpeak, peakmodifier, modifierionizing, ionizingrsd, rsdexchanger
Analysis of Pesticides by Supercritical Fluid Chromatography/ Mass Spectrometry
Analysis of Pesticides by Supercritical Fluid Chromatography/ Mass Spectrometry Optimizing the Agilent 1260 Infinity Analytical SFC System in Combination with the Agilent 6460 Triple Quadrupole LC/MS Application Note Food Testing & Agriculture Author Abstract Edgar Naegele This Application Note describes…
Key words
sfc, sfcflow, flowmethabenzthiazuron, methabenzthiazuronmau, maufinal, finalmakeup, makeupatrazine, atrazineagilent, agilenthexazinone, hexazinonemasshunter, masshuntermodifier, modifiermrm, mrmmetolachlor, metolachloroptimized, optimizedmetoxuron
Veterinary Drug Analysis with Supercritical Fluid Chromatography and Triple Quadrupole LC/MS
Veterinary Drug Analysis with Supercritical Fluid Chromatography and Triple Quadrupole LC/MS The Agilent 1260 Infinity Analytical SFC Solution and Agilent 6490 Triple Quadrupole LC/MS Application Note Food Testing and Agriculture Authors Abstract Edgar Naegele, Joachim Thiemann, This Application Note describes…
Key words
sfc, sfcmapenterol, mapenterolflow, flowbromoclenbuterol, bromoclenbuterolchlorbrombuterol, chlorbrombuterolmethylmabuterol, methylmabuterolveterinary, veterinaryclenbuterolhydroxymethyl, clenbuterolhydroxymethylclencyclohexerol, clencyclohexerolisolait, isolaitbackpressure, backpressureclenpenterol, clenpenterolbpr, bprclenproperol, clenproperolmabuterol
Fast Analysis of Chiral and Structurally Related Isomers Using Supercritical Fluid Chromatography Mass Spectrometry
Fast Analysis of Chiral and Structurally Related Isomers Using Supercritical Fluid Chromatography Mass Spectrometry Application Note Authors Abstract Yuqin Dai and Lisa Zang This Application Note demonstrates the use of Agilent 1260 Infinity Analytical Agilent Technologies, Inc. Supercritical Fluid Chromatography…
Key words
sfc, sfcchiral, chiralmodifier, modifieratenolol, atenololflow, flowwarfarin, warfarinseparation, separationstructurally, structurallyefficiency, efficiencybpr, bprimpurity, impuritysil, silmin, minzorbax, zorbaxprednisolone
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike