Agilent CE System - A Quick Start Guide to Maintenance and Troubleshooting

Guides | 2000 | Agilent TechnologiesInstrumentation
Capillary electrophoresis
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Capillary electrophoresis is a versatile analytical technique widely used for separation of ionic species based on charge and size. Regular maintenance and rapid troubleshooting are essential to ensure reliable performance, consistent migration times, reproducible peak areas, and extended instrument lifetime. Proper upkeep reduces downtime and improves data quality in pharmaceutical, biotech, environmental, and quality-control laboratories.

Objectives and Overview


The guide aims to provide a concise set of best practices for maintaining an Agilent capillary electrophoresis (CE) system, diagnosing common problems, and optimizing CE methods. It covers:
  • Practical considerations for capillary, samples, buffers, and data analysis
  • Preventive maintenance for injection, replenishment, and detection modules
  • Troubleshooting key performance issues
  • Workflows for CE method development and optimization

Methodology and Instrumentation


Practical Considerations:
  • Capillary management: use one capillary per method, recut or replace broken capillaries, keep detection windows clean, store by flushing with water and air
  • Sample handling: remove particulates by filtration or centrifugation, control temperature for sensitive samples
  • Buffer preparation: employ high-quality reagents, filter solutions (0.2–0.45 µm), use CE-grade water, monitor pH precisely, prepare fresh buffers to avoid drift
  • Data analysis: target migration time RSD ≤1 %, area RSD ≤3 %, use corrected peak area for quantification, ensure adequate data points per peak
Instrumental Preventive Maintenance:
  • Injection system: clean electrodes and prepunchers weekly, inspect for salt deposits, bent components, or worn O-rings
  • Replenishment system: flush tubing, clean with isopropanol/water, inspect needles and frits, replace worn O-rings, avoid long-term buffer storage
  • Detection system: inspect optical interface for debris, clean capillary window, perform regular lamp checks and DAD tests

Main Results and Discussion


Following these recommendations leads to stable currents, sharp peaks, and consistent migration times. Common problems such as noisy baselines, poor resolution, or injection failures can be resolved by addressing buffer quality, capillary conditioning, alignment interface cleanliness, and injection settings. The method development flowchart guides selection of initial buffer systems according to analyte charge and suggests adjustments—such as surfactant concentration in MEKC or pH and ionic strength in CZE—to optimize separation.

Benefits and Practical Applications


Implementing structured maintenance and troubleshooting protocols:
  • Enhances reproducibility and accuracy of quantitative analyses
  • Reduces instrument downtime and extends capillary lifetime
  • Facilitates robust method transfer and compliance with regulatory standards
  • Supports high-throughput workflows in pharmaceutical, food safety, and environmental testing

Future Trends and Potential Applications


Emerging directions include integration of automated cleaning routines, advanced capillary coatings to minimize adsorption, on-line preconcentration techniques for trace analysis, and coupling CE with mass spectrometry for comprehensive profiling. Data-driven diagnostics and remote monitoring may further streamline maintenance and early fault detection.

Conclusion


A disciplined approach to preventive maintenance, guided troubleshooting, and systematic method optimization ensures reliable CE performance. By adhering to best practices and adopting technological advances, laboratories can achieve consistent, high-quality separations and efficient workflow management.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
CE & CE/MS Troubleshooting Guide
CE & CE/MS Troubleshooting Guide
2022|Agilent Technologies|Posters
CE & CE/MS Troubleshooting Guide Your guide to solving common problems and staying productive Places to Start CE Solvents Daily tasks CE/MS – Use CE-suitable vials that are pressure resistant. – If the CE and MS systems are in idle…
Key words
capillary, capillarycause, causebuffer, bufferpossible, possiblesprayer, sprayerbge, bgesolution, solutionsiphoning, siphoningsheath, sheathcheck, checkflush, flushcurrent, currentunstable, unstableavoid, avoidtoo
Maximize your Capillary Electrophoresis System - GUIDE TO CAPILLARIES, REAGENTS, AND SUPPLIES FOR CE
Maximize your Capillary Electrophoresis System GUIDE TO CAPILLARIES, REAGENTS, AND SUPPLIES FOR CE CONTENTS Table of Contents CE Solutions Kits 4 Inorganic Anion Solutions Kit 5 Cation Solutions Kit 6 Organic Acids Solutions Kit 7 Forensic Anions Solutions Kit 8…
Key words
capillaries, capillariescapillary, capillarykit, kitµsil, µsilalignment, alignmentbuffer, bufferpva, pvalength, lengthcoated, coateddescription, descriptionsolutions, solutionskits, kitscell, cellinterfaces, interfacesgray
Simultaneous analysis of inorganic anions, organic acids, amino acids and carbohydrates using the Agilent Basic Anion Buffer
Simultaneous analysis of inorganic anions, organic acids, amino acids and carbohydrates using the Agilent Basic Anion Buffer Application Note Food Tomoyoshi Soga 1 2 3 4 5 6 7 8 Absorbance [mAU] 12.5 Br Cl NO2 NO3 SO4 Oxalate F…
Key words
buffer, buffercapillary, capillarymalate, malateanion, anionser, serngna, ngnacitrate, citrateanions, anionsshould, shouldagilent, agilentreplace, replacenana, nanainorganic, inorganiclactate, lactateglucose
My Chromatography Has Changed: Steps for Effective Troubleshooting
My Chromatography Has Changed: Steps for Effective Troubleshooting Jean Lane Applications Engineer LC Columns and Consumables Technical Support June 18, 2024 1 6/18/2024 My Chromatography has Changed: Steps for Effective Troubleshooting DE13277529 Common Symptoms and Problems • Increased pressure •…
Key words
mobile, mobilephase, phasecolumn, columnpressure, pressurefilter, filtercheck, checkaction, actionfitting, fittingpeak, peakquick, quickyour, yourconnections, connectionsuse, useinfinitylab, infinitylabtailing
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike