Agilent 6400 Series Triple Quad LC/MS System - Quick Start Guide
Manuals | 2010 | Agilent TechnologiesInstrumentation
The Agilent 6400 Series Triple Quadrupole LC/MS system delivers high-sensitivity, high-selectivity tandem mass spectrometry for targeted analyses in pharmaceuticals, environmental monitoring, food safety and clinical research. Its multiple reaction monitoring workflow enables accurate quantitation of trace compounds with rapid polarity switching and broad mass range coverage.
This Quick Start Guide provides a step-by-step roadmap for installing, configuring and operating the Agilent 6400 Series Triple Quad LC/MS. It covers software launch, LC module preparation, instrument tuning, acquisition method setup, real-time monitoring and basic qualitative and quantitative data review.
Instrumentation used in this guide:
Key methodological steps:
Following this guide ensures rapid system readiness and reproducible data acquisition. Dynamic MRM capability supports large transition lists with precise time-segmented monitoring. Fast polarity switching (30–500 ms) expands analyte coverage. Integrated software modules streamline method development, compliance tracking, data processing and reporting.
Emerging trends include expanded transition libraries for metabolomics, integration of ion mobility separations, automated AI-driven data interpretation and enhanced multiplexing strategies. Advancements in source design and ultra-high-speed scanning will further boost throughput and analytical depth.
The Quick Start Guide simplifies initial deployment of the Agilent 6400 Series Triple Quad LC/MS, guiding users through system installation, method setup and basic data review. By following these procedures, laboratories achieve consistent, high-performance tandem MS analyses tailored to diverse application needs.
Agilent 6400 Series Triple Quad LC/MS Quick Start Guide, Agilent Technologies; MassHunter Workstation Software Documentation; Installation, Concepts and Maintenance Guides for Agilent Triple Quad LC/MS.
LC/MS, LC/MS/MS, LC/QQQ
IndustriesManufacturerAgilent Technologies
Summary
Significance of the topic
The Agilent 6400 Series Triple Quadrupole LC/MS system delivers high-sensitivity, high-selectivity tandem mass spectrometry for targeted analyses in pharmaceuticals, environmental monitoring, food safety and clinical research. Its multiple reaction monitoring workflow enables accurate quantitation of trace compounds with rapid polarity switching and broad mass range coverage.
Objectives and overview of the guide
This Quick Start Guide provides a step-by-step roadmap for installing, configuring and operating the Agilent 6400 Series Triple Quad LC/MS. It covers software launch, LC module preparation, instrument tuning, acquisition method setup, real-time monitoring and basic qualitative and quantitative data review.
Methodology and instrumentation
Instrumentation used in this guide:
- Agilent 6400 Series Triple Quadrupole LC/MS with Jet Stream ion source
- Agilent 1100 or 1200 LC modules (autosampler, binary pump, DAD, TCC)
- Agilent MassHunter Workstation Software: Data Acquisition, Qualitative Analysis, Quantitative Analysis, Study Manager, Map File Generator
- Agilent 1290 Infinity high-performance autosampler (G4226A), binary pump (G4220A), DAD (G4212A), TCC (G1316C)
Key methodological steps:
- Launch the Data Acquisition software and familiarize with the Instrument Status, Real-time Plot, Method Editor and Worklist panes.
- Prepare LC modules: switch flow to waste, purge pumps, condition and equilibrate the column while monitoring baselines.
- Tune the mass spectrometer using Checktune, Autotune or Manual Tune to achieve target mass accuracy and resolution.
- Switch LC flow to MS source, verify stable MS baseline and spectral display.
- Define acquisition methods: select scan type (MRM or scan segments), enter LC and MS parameters, configure dynamic MRM for up to 4000 transitions.
- Execute runs interactively or via worklists; monitor chromatograms and spectra in real time.
- Review qualitative data to confirm transition selection and compound identification; perform quantitative analysis batches using calibration curves and batch-at-a-glance reports.
Main results and discussion
Following this guide ensures rapid system readiness and reproducible data acquisition. Dynamic MRM capability supports large transition lists with precise time-segmented monitoring. Fast polarity switching (30–500 ms) expands analyte coverage. Integrated software modules streamline method development, compliance tracking, data processing and reporting.
Benefits and practical applications
- Efficient setup reduces instrument downtime and accelerates analytical workflows.
- Robust dynamic MRM enhances sensitivity for complex sample matrices.
- Modular software enables consolidated method creation, data acquisition and review in a unified user interface.
- Compliance features and logbook notifications support regulated environments.
Future trends and potential applications
Emerging trends include expanded transition libraries for metabolomics, integration of ion mobility separations, automated AI-driven data interpretation and enhanced multiplexing strategies. Advancements in source design and ultra-high-speed scanning will further boost throughput and analytical depth.
Conclusion
The Quick Start Guide simplifies initial deployment of the Agilent 6400 Series Triple Quad LC/MS, guiding users through system installation, method setup and basic data review. By following these procedures, laboratories achieve consistent, high-performance tandem MS analyses tailored to diverse application needs.
References
Agilent 6400 Series Triple Quad LC/MS Quick Start Guide, Agilent Technologies; MassHunter Workstation Software Documentation; Installation, Concepts and Maintenance Guides for Agilent Triple Quad LC/MS.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 6400 Series Triple Quad LC/MS System - Quick Start Guide
2018|Agilent Technologies|Manuals
Agilent 6400 Series Triple Quad LC/MS System Quick Start Guide Where to find information 4 Getting Started 7 Step 1. Start the Data Acquisition software 8 Step 2. Prepare the LC modules 14 Step 3. Prepare the Triple Quad LC/MS…
Key words
getting, gettingstarted, startedwindow, windowguide, guideyou, youmasshunter, masshunteracquisition, acquisitionworkstation, workstationclick, clicklearn, learnfamiliarization, familiarizationdata, datause, useautotune, autotunequalitative
Agilent 6400 Series Triple Quad LC/MS System - Quick Start Guide
2018|Agilent Technologies|Manuals
Agilent 6400 Series Triple Quad LC/MS System Quick Start Guide What is the Agilent 6400 Series Triple Quad LC/MS? What’s New in Data Acquisition 3 Where to find information 4 Help 4 Installation and User Guides Training 5 4 Getting…
Key words
getting, gettingstarted, startedwindow, windowguide, guideyou, youmasshunter, masshunteracquisition, acquisitionclick, clickdata, datastart, startworkstation, workstationlearn, learnfamiliarization, familiarizationqualitative, qualitativemethod
Agilent 6400 Series Triple Quadrupole LC/MS System - Quick Start Guide
2017|Agilent Technologies|Manuals
Agilent 6400 Series Triple Quadrupole LC/MS System Quick Start Guide Where to find information 4 Getting Started 7 Step 1. Start the Data Acquisition software 8 Step 2. Prepare the LC modules 14 Step 3. Prepare the Triple Quadrupole instrument…
Key words
getting, gettingstarted, startedguide, guidewindow, windowyou, youefamiliarization, efamiliarizationlearn, learnuse, usefamiliarization, familiarizationacquisition, acquisitionexercises, exercisesqualitative, qualitativefollow, followmasshunter, masshunterclick
Agilent Triple Quad Mass Spectrometer (Model K6460 and K6420) - Quick Start Guide
2018|Agilent Technologies|Manuals
Agilent Triple Quad Mass Spectrometer (Model K6460 and K6420) Quick Start Guide For In Vitro Diagnostic Use The K6460 and K6420 mass spectrometers are intended to be used to identify inorganic or organic compounds in human specimens by ionizing the…
Key words
getting, gettingstarted, startedwindow, windowguide, guideyou, youfamiliarization, familiarizationclick, clickuse, uselearn, learnstatus, statusexercises, exercisesacquisition, acquisitionautotune, autotunemethod, methodqualitative