Agilent MassHunter BioConfirm - Quick Start Guide
Manuals | 2018 | Agilent TechnologiesInstrumentation
Efficient confirmation and quantitation of biomolecules such as intact proteins, peptides, and released glycans is critical for research, QC/QA, and biopharmaceutical development. Automated software workflows reduce manual data handling, improve reproducibility, and accelerate time-to-result in complex LC-MS and LC-MS/MS analyses.
The Agilent MassHunter BioConfirm Quick Start Guide introduces version 10.0 of a software suite designed for automated and interactive confirmation of biomolecules using TOF and Q-TOF data. The guide details installation, user interface components, workflow setup, sequence management, data processing steps for three main applications (Intact Protein, Protein Digest, Released Glycans), and new features introduced in 10.0 for cross-sample comparison and customizable layouts.
Version 10.0 enhancements enable:
The modular architecture and API-driven design of BioConfirm could evolve to integrate machine learning-based peak detection, cloud-based data sharing, and real-time process analytics. Expanded glyco- and proteoform libraries, enhanced support for top-down MS/MS fragmentation, and tighter integration with laboratory information management systems are anticipated to further streamline biomolecular characterization workflows.
Agilent MassHunter BioConfirm version 10.0 offers a robust, automated platform for comprehensive confirmation and relative quantitation of intact proteins, digested peptides, and released glycans. The intuitive UI, customizable methods, and advanced comparison tools deliver significant productivity gains for analytical chemists and biopharmaceutical scientists.
Agilent MassHunter BioConfirm Software Quick Start Guide (G6829AA), Revision A, August 2018
Software
IndustriesProteomics
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Efficient confirmation and quantitation of biomolecules such as intact proteins, peptides, and released glycans is critical for research, QC/QA, and biopharmaceutical development. Automated software workflows reduce manual data handling, improve reproducibility, and accelerate time-to-result in complex LC-MS and LC-MS/MS analyses.
Objectives and Overview
The Agilent MassHunter BioConfirm Quick Start Guide introduces version 10.0 of a software suite designed for automated and interactive confirmation of biomolecules using TOF and Q-TOF data. The guide details installation, user interface components, workflow setup, sequence management, data processing steps for three main applications (Intact Protein, Protein Digest, Released Glycans), and new features introduced in 10.0 for cross-sample comparison and customizable layouts.
Used Instrumentation
- Agilent Time-of-Flight (TOF) and Quadrupole-TOF (Q-TOF) mass spectrometers
- Microsoft Excel (for report templates and generation)
- Agilent MassHunter BioConfirm Software v10.0
- Agilent MassHunter Sequence Manager
Methodology and Software Workflow
- Intact Protein Workflow: Automated deconvolution (Maximum Entropy or pMod algorithm) to generate zero-charge spectra followed by sequence matching with variable and site-specific modifications.
- Protein Digest Workflow: Peptide feature extraction (PFE) in LC-MS/MS data, enzymatic digestion rules, sequence matching, and false discovery rate filtering for peptide identification.
- Released Glycans Workflow: Target glycan database search with retention time filtering, tagging options (e.g., 2-AB, InstantPC), and glycan grouping for quantitation.
- Custom Workflow: User-selectable actions to combine specific find, deconvolute, or match steps.
- Report Automation: Built-in templates for each workflow and support for Excel-based report generation.
Main Results and Discussion
Version 10.0 enhancements enable:
- Switchable and savable UI layouts for different workflows.
- Results Compare window for side-by-side quantitation across up to ten samples.
- Relative quantitation histograms for predicted modifications, peptides, or glycans grouped by biomolecule or sample.
- Automatic calculation of average and %RSD for glycan groups.
- Improved peptide matching under non-reduced conditions via MS1 mass accuracy fallback.
Benefits and Practical Applications
- High-throughput confirmation and quantitation reduces manual review time.
- Integrated visualization panels (chromatograms, spectra, deconvolution, sequence coverage) support rapid data interrogation.
- Flexible sequence editing with variable modifications and disulfide link management in Sequence Manager.
- Automated report generation simplifies documentation for regulatory or internal review.
- Cross-sample comparison tools facilitate relative quantitation studies in biomarker discovery and bioprocess monitoring.
Future Trends and Applications
The modular architecture and API-driven design of BioConfirm could evolve to integrate machine learning-based peak detection, cloud-based data sharing, and real-time process analytics. Expanded glyco- and proteoform libraries, enhanced support for top-down MS/MS fragmentation, and tighter integration with laboratory information management systems are anticipated to further streamline biomolecular characterization workflows.
Conclusion
Agilent MassHunter BioConfirm version 10.0 offers a robust, automated platform for comprehensive confirmation and relative quantitation of intact proteins, digested peptides, and released glycans. The intuitive UI, customizable methods, and advanced comparison tools deliver significant productivity gains for analytical chemists and biopharmaceutical scientists.
Reference
Agilent MassHunter BioConfirm Software Quick Start Guide (G6829AA), Revision A, August 2018
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent MassHunter BioConfirm Software - Familiarization Guide
2018|Agilent Technologies|Manuals
Agilent MassHunter BioConfirm Software Familiarization Guide For Research Use Only. Not for use in diagnostic procedures. Basic Tasks 3 Task 1. Open the BioConfirm program 3 Task 2. Zoom in and out of the chromatogram 6 Task 3. Change window…
Key words
click, clickbioconfirm, bioconfirmfamiliarization, familiarizationcomments, commentsmasshunter, masshunterbiomolecule, biomoleculeinstructions, instructionsguide, guidesteps, stepsdetailed, detailedyou, youagilent, agilentworkflow, workflowsoftware, softwareprotein
MassHunter BioConfirm 12.0 - Introduction Guide
2022|Agilent Technologies|Manuals
MassHunter BioConfirm 12.0 Introduction Guide Where to find more information Where to find more information How to use this guide 3 Basic Tasks 1 5 Task 1. Open the BioConfirm program 5 Task 2. Zoom in and out of the…
Key words
click, clickbioconfirm, bioconfirmcomments, commentsmasshunter, masshunteryou, youguide, guideinstructions, instructionsbiomolecule, biomoleculeworkflow, workflowsteps, stepsdetailed, detailedagilent, agilentselect, selectsequence, sequencesoftware
Agilent MassHunter BioConfirm Software - Quick Start Guide
2016|Agilent Technologies|Manuals
Agilent MassHunter BioConfirm Software Quick Start Guide For Research Use Only. Not for use in diagnostic procedures. What is Agilent MassHunter BioConfirm Software? 3 Agilent MassHunter BioConfirm Software Installation 7 User Interface 8 Workflows and Sequences 17 Intact Protein Workflow…
Key words
bioconfirm, bioconfirmmasshunter, masshunterprotein, proteinguide, guidequick, quickstart, startbiomolecule, biomoleculesequences, sequencesagilent, agilentsequence, sequenceworkflow, workflowsoftware, softwaredeconvolution, deconvolutionwindow, windowintact
Agilent Technologies Agilent MassHunter BioConfirm Software
2011|Agilent Technologies|Manuals
Agilent MassHunter BioConfirm Software Quick Start Guide What is Agilent MassHunter BioConfirm Software? 2 Agilent MassHunter BioConfirm Software Installation 3 Deconvolution Features and Parameters 4 Sequence Matching Features and Parameters 8 Deconvolution Workflow 13 To deconvolute selected spectra 15 To…
Key words
bioconfirm, bioconfirmsequence, sequencemasshunter, masshunterdeconvolution, deconvolutionsequences, sequencesguide, guidematching, matchingquick, quickstart, startagilent, agilentclick, clicksoftware, softwarematch, matchdigest, digestprotein