Thermo Scientific Vanquish Column Compartments - PRODUCT SPECIFICATIONS

Brochures and specifications | 2019 | Thermo Fisher ScientificInstrumentation
HPLC
Industries
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


The precise control of column temperature and modular compartment design are critical for achieving reproducible, high‐resolution liquid chromatography separations. Advanced temperature management influences retention, selectivity, and analysis speed, while flexible compartment configurations enhance workflow throughput and method transfer across HPLC and UHPLC platforms.

Study Objectives and Overview


This document presents detailed specifications and performance characteristics of Thermo Scientific Vanquish Column Compartments (models H and C), active and passive pre‐heaters, and a post‐column cooler. The goal is to demonstrate how optimized temperature control, capacity, and integration with chromatography data systems support robust, high‐precision analytical workflows.

Methodology and Instrumentation Used


  • Vanquish Column Compartment H (forced air & still air thermostatting)
  • Vanquish Column Compartment C (forced air & still air thermostatting)
  • Active and passive pre‐heaters for column inlet conditioning
  • Post‐column cooler for temperature stabilization after separation
  • Viper fingertight fittings for reduced dead volume and simplified setup
  • Biocompatible flow paths (titanium, ceramics, MP35N alloys)
  • Column switching valves (2-position/6-port and 6-position/7-port)
  • Column ID tag system integrated into Chromeleon Chromatography Data System

Key Results and Discussion


Column Compartment H achieves a temperature range of 5–120 °C with stability of ±0.05 °C and accuracy of ±0.5 °C. It heats from 20–50 °C within 15 minutes and cools from 50–20 °C in under 15 minutes. Compartment C covers 5–85 °C with similar stability, heating 25–40 °C in 5 minutes. Both modules accommodate two columns (up to 300 mm length, 10 mm i.d.) and offer active pre‐heating, optional passive pre‐heaters, and up to two column switching valves. The active pre‐heater delivers 40–120 °C with rapid heat‐up at typical flow rates, while the post‐column cooler passively lowers temperatures down to 50 °C. Biocompatible versions support pH 2–12 and high chloride concentrations. Integrated leak sensors, dual doors, and fast‐cool buttons enhance safety. Predictive performance functions and audit‐trail logging in Chromeleon CDS enable proactive maintenance and regulatory compliance.

Benefits and Practical Applications


  • Enhanced reproducibility and selectivity through precise temperature control
  • Faster method development and sample throughput via rapid heating/cooling
  • Seamless transfer of methods between laboratories using forced or still‐air modes
  • High‐throughput workflows with multi‐column capacity and automated valve switching
  • Regulatory compliance and traceability ensured by integrated column ID and audit trails
  • Biocompatible flow paths extend use to bioanalysis and proteomics

Future Trends and Opportunities


Emerging developments may include AI‐driven predictive maintenance analytics, expanded temperature ranges for novel stationary phases, further miniaturization of column compartments, wireless remote monitoring of temperature zones, and tighter integration with autosamplers and mass spectrometers for fully automated high‐throughput platforms.

Conclusion


Thermo Scientific Vanquish Column Compartments and associated temperature management accessories deliver exceptional control, versatility, and integration, enabling laboratories to achieve high precision, reproducibility, and efficiency across a wide range of LC and LC–MS applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Viper and nanoViper Fingertight Fitting Systems - PRODUCT SPECIFICATIONS
Viper and nanoViper Fingertight Fitting Systems - PRODUCT SPECIFICATIONS
2021|Thermo Fisher Scientific|Brochures and specifications
LC and LC-MS PRODUCT SPECIFICATIONS Viper and nanoViper Fingertight Fitting Systems Tool-free LC connections for HPLC, UHPLC and low-flow UHPLC systems Benefits The Thermo Scientific™ Viper™ and Thermo Scientific™ nanoViper™ • Provides virtually zero-dead volume fingertight connections Fingertight Fitting Systems…
Key words
viper, viperfingertight, fingertightvanquish, vanquishsystems, systemsnanoviper, nanoviperfitting, fittingkit, kitdiameter, diameteruhplc, uhplcconnection, connectionthermo, thermomaximum, maximumwetted, wettedscientific, scientificouter
Thermo Scientific Vanquish Neo UHPLC System - PRODUCT SPECIFICATIONS
Thermo Scientific Vanquish Neo UHPLC System - PRODUCT SPECIFICATIONS
2021|Thermo Fisher Scientific|Brochures and specifications
LC-MS PRODUCT SPECIFICATIONS Vanquish Neo UHPLC System The new standard in nano-, capillary-, and micro-flow LC Beyond discovery The Thermo Scientific™ Vanquish™ Neo UHPLC system is all-inone nano-, capillary-, and micro-flow LC system that is ready for high sensitivity LC-MS…
Key words
vanquish, vanquishneo, neosystem, systempump, pumpcompartment, compartmentinterlink, interlinkuhplc, uhplcinjection, injectionvici, vicipiston, pistonoperating, operatinglogged, loggedpressure, pressurerange, rangefeatures
Transcend LX UHPLC Systems
Transcend LX UHPLC Systems
2025|Thermo Fisher Scientific|Brochures and specifications
Product specifications | 73841 HPLC & UHPLC Transcend LX UHPLC Systems Boost LC-MS throughput to a new level The unique multichannel LC capability of the Thermo Scientific™ Transcend™ LX UHPLC systems increases throughput by up to four times, maximizing mass…
Key words
multichannel, multichanneltemperature, temperaturerange, rangeinjection, injectiontranscend, transcendpressure, pressurecapacity, capacitymaximum, maximumvanquish, vanquishuhplc, uhplctriplus, triplusoperating, operatingvolume, volumecolumn, columnautosampler
Thermo Scientific Dionex UltiMate 3000 Series - Column Compartments TCC-3000SD and TCC-3000RS
Thermo Scientific Dionex UltiMate 3000 Series Column Compartments TCC-3000SD and TCC-3000RS Operating Instructions (Original Operating Instructions) Revision: 1.5 Date: September 2013 © 2013 Thermo Fisher Scientific Inc. Doc. No. 4827.3050 UltiMate 3000 Series: TCC-3000SD and TCC-3000RS Column Compartments Operating Instructions…
Key words
instructions, instructionstcc, tccoperating, operatingcolumn, columnchromeleon, chromeleonvalve, valvecooler, coolervalves, valvesdes, desswitching, switchingturn, turnpost, postinstallation, installationtemperature, temperaturepower
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike