Determination of Zolmitriptan in Serum by SPE-LC-MS/MS
Applications | 2013 | Thermo Fisher ScientificInstrumentation
Zolmitriptan is a serotonin receptor agonist widely prescribed for migraine relief. Monitoring its serum concentration supports pharmacokinetic studies, therapeutic drug monitoring, and clinical research. A sensitive and robust analytical method enables reliable quantification at low levels, ensuring data quality in biomedical applications.
This study aimed to develop and validate a rapid SPE-LC-MS/MS protocol for quantifying zolmitriptan in human serum. The objectives included achieving a low limit of quantification (LOQ), high recovery and reproducibility, and a short chromatographic run time. Thermo Scientific SOLA CX solid phase extraction and Hypersil GOLD UHPLC columns were evaluated to meet these goals.
The presented SPE-LC-MS/MS method achieves sensitive, precise, and rapid quantification of zolmitriptan in serum. Use of SOLA CX SPE and Hypersil GOLD UHPLC technology delivers high recovery and sharp chromatographic peaks in a streamlined workflow. This approach is well suited for clinical research and therapeutic monitoring where speed, accuracy, and reproducibility are essential.
This summary is based on: Phipps K. Determination of Zolmitriptan in Serum by SPE-LC-MS/MS. Thermo Fisher Scientific Application Note 20689, 2013.
Sample Preparation, Consumables, LC/MS, LC/MS/MS, LC/QQQ
IndustriesClinical Research
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Zolmitriptan is a serotonin receptor agonist widely prescribed for migraine relief. Monitoring its serum concentration supports pharmacokinetic studies, therapeutic drug monitoring, and clinical research. A sensitive and robust analytical method enables reliable quantification at low levels, ensuring data quality in biomedical applications.
Aims and Overview of the Study
This study aimed to develop and validate a rapid SPE-LC-MS/MS protocol for quantifying zolmitriptan in human serum. The objectives included achieving a low limit of quantification (LOQ), high recovery and reproducibility, and a short chromatographic run time. Thermo Scientific SOLA CX solid phase extraction and Hypersil GOLD UHPLC columns were evaluated to meet these goals.
Used Methodology and Instrumentation
- Sample preparation by SOLA CX SPE cartridges featuring conditioning with methanol and formic acid, followed by washing and ammonia/methanol elution.
- Reconstitution of dried extracts in water after nitrogen evaporation.
- Chromatography using a Hypersil GOLD 1.9 µm, 50×2.1 mm column on an Ultimate 3000 UHPLC system with a 5–95% acetonitrile gradient in 1 minute at 1 mL/min, 60 °C, 2.5 min total run time.
- Detection by TSQ Vantage triple quadrupole MS with APCI positive ionization, monitoring transitions m/z 288.2→182.2 for zolmitriptan and 256.2→167.2 for the internal standard diphenhydramine.
Main Results and Discussion
- LOQ of 1 ng/mL with linear response over 1–100 ng/mL (r2 = 0.996).
- Extraction recovery averaged 88.2% for zolmitriptan, demonstrating high method efficiency.
- Precision was excellent, with CV values below 7.5% across low, medium, and high QC levels.
- Chromatograms showed sharp, symmetrical peaks in a 2 minute analysis time, confirming fast and reliable separation.
Benefits and Practical Applications of the Method
- High throughput: fast sample preparation and a 2.5 min run time support large batch analysis.
- Low sample and solvent consumption reduce operational costs and environmental impact.
- Robust performance in complex matrices ensures reliable data for clinical trials, bioavailability studies, and therapeutic monitoring.
Future Trends and Potential Applications
- Integration with automated sample handling to further increase throughput and reproducibility.
- Extension to multiplexed assays for simultaneous measurement of multiple triptans or other migraine therapeutics.
- Application in pharmacokinetic profiling in special populations such as pediatric or renal-impaired patients.
- Adaptation to high-resolution MS for metabolite identification and profiling.
Conclusion
The presented SPE-LC-MS/MS method achieves sensitive, precise, and rapid quantification of zolmitriptan in serum. Use of SOLA CX SPE and Hypersil GOLD UHPLC technology delivers high recovery and sharp chromatographic peaks in a streamlined workflow. This approach is well suited for clinical research and therapeutic monitoring where speed, accuracy, and reproducibility are essential.
Reference
This summary is based on: Phipps K. Determination of Zolmitriptan in Serum by SPE-LC-MS/MS. Thermo Fisher Scientific Application Note 20689, 2013.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
2013|Thermo Fisher Scientific|Applications
Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract A liquid chromatography–tandem mass spectrometry method for the analysis of dextromethorphan and dextrorphan from rat plasma has been developed. A limit of quantification…
Key words
dextrorphan, dextrorphandextromethorphan, dextromethorphanoverspike, overspikeaverage, averageratio, ratioresponse, responseqch, qchqcl, qclqcm, qcmsola, solaspe, spefisher, fishergrade, gradesuppression, suppressionplasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma
2013|Thermo Fisher Scientific|Applications
Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Appli cat i on N ote 2 0 6 8 7 LC-MS/MS Method for the Determination of Tenofovir from Plasma Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract A liquid chromatography-tandem…
Key words
tenofovir, tenofovirsola, solafisher, fishergentle, gentlegrade, gradescientific, scientificscientifictm, scientifictmvacuum, vacuumconcentration, concentrationthermo, thermounder, underpart, parthypersil, hypersilspe, speplasma
SPE and LC-MS/MS Method for the Determination of 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 from Human Plasma
2014|Thermo Fisher Scientific|Applications
Joanne Jones, Thermo Fisher Scientific, Runcorn, UK Appli cat i on N ote 2 0 9 3 6 SPE and LC-MS/MS Method for the Determination of 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 from Human Plasma Key Words Solid phase extraction, SPE,…
Key words
overspike, overspikeaverage, averageresponse, responsearea, areaqch, qchqcl, qclqcm, qcmvitamin, vitaminfisher, fishergrade, gradeconcentration, concentrationscientific, scientifichormone, hormonerecovery, recoverypart
SPE and LC-MS/MS method for the determination of 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 from human plasma
2020|Thermo Fisher Scientific|Applications
APPLICATION NOTE No. 20936 SPE and LC-MS/MS method for the determination of 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 from human plasma Authors: Jon Bardsley, Ken Meadows, Joanne Jones, Thermo Fisher Scientific, Runcorn, UK Keywords: Solid phase extraction, SPE, SOLA HRP, LC-MS/MS,…
Key words
response, responseoverspike, overspikeaverage, averagearea, areaqch, qchqcl, qclqcm, qcmgrade, gradeconcentration, concentrationarb, arbscientifictm, scientifictmrecovery, recoverythermo, thermoexperimentalhdetails, experimentalhdetailsvitamin