Agilent Biocolumns - Charge Variant Analysis - Application Compendium

Guides | 2021 | Agilent TechnologiesInstrumentation
Consumables, HPLC, LC/TOF, LC/HRMS, LC/MS, LC/MS/MS, LC columns, 2D-LC
Industries
Pharma & Biopharma, Proteomics
Manufacturer
Agilent Technologies

Summary

Význam tématu


Ion-exchange chromatography (IEX) is a cornerstone technique for the separation and characterization of charged biomolecules, particularly monoclonal antibodies (mAbs). Charge variants arising from post-translational modifications such as deamidation, lysine truncation, and glycan sialylation can profoundly affect the safety and efficacy of biotherapeutics. High-resolution analysis of these variants is therefore essential in drug development, quality control, and biosimilar comparability studies.

Cíle a přehled studie / článku


This compendium and series of application notes aim to provide a comprehensive, practical guide to IEX method development and advanced workflows for biomolecule charge variant analysis. Key objectives include:
  • Presenting fundamental principles and method-development strategies for IEX of proteins and peptides
  • Demonstrating use of Agilent Bio IEX and Bio MAb columns with nonporous particles for improved resolution
  • Introducing Agilent Buffer Advisor software for automated salt and pH gradient generation
  • Illustrating advanced multidimensional LC-MS workflows, including 4D-LC/MS, for in-depth variant identification and peptide mapping
  • Comparing innovator versus biosimilar mAb charge profiles and accelerated stability stress testing

Použitá metodika a instrumentace


Methodology across the studies encompasses:
  • CEX separations on Agilent Bio IEX (WCX/SCX) and Bio MAb columns (1.7–5 µm nonporous particles, PEEK or stainless steel hardware) using salt or pH gradients
  • Mobile phases based on phosphate, acetate, MOPS, or composite buffers dynamically mixed by Buffer Advisor via an Agilent 1260/1290 Infinity Bio-inert Quaternary LC or Bio Prime LC system
  • Gradient optimization guided by isoelectric point scouting and design-of-experiments (DOE) approaches
  • Online desalting, denaturation, reduction, and proteolytic digestion using multi-heart-cutting 2D-LC with trapping cartridges and Orachrom StyrosZyme trypsin columns
  • Final peptide mapping on reversed-phase columns (AdvanceBio peptide mapping) coupled to Q-TOF MS for sequence coverage and modification localization

Hlavní výsledky a diskuse


Key findings include:
  • Nonporous Bio IEX particles eliminate diffusion-limited band broadening, permitting significant reductions in column length and particle size without loss of resolution
  • Shorter 4.6 × 50 mm columns with 1.7 µm or 3 µm particles enable 2–4 min IEX separations at sub-600 bar pressures
  • Automated Buffer Advisor gradients reduce buffer-preparation effort from dozens of premixed bottles to four stock solutions, ensuring accurate pH and ionic strength control
  • High retention-time precision (RSD < 0.1 % for main peaks) demonstrated for mAbs at shallow salt slopes (2.5–5 mM/min)
  • Charge-variant profiles of trastuzumab and NISTmAb reveal acidic and basic isoforms, with Buffer Advisor enabling rapid pH scouting and method transfer
  • Comparative CEX profiles of innovator versus biosimilar rituximab show distinct ratios of acidic, main, and basic peaks; CPB digestion confirms C-terminal lysine variants
  • 4D-LC/MS workflow fully automates variant characterization: CEX peak collection, on-column desalting/reduction, online trypsin digestion, and peptide mapping identify deamidation (Asn→Asp) and isomerization (Asp→isoAsp) sites in light and heavy chains

Přínosy a praktické využití metody


The integrated methods provide:
  • High throughput: sub-five-minute IEX runs and automated multidimensional LC-MS reduce hands-on time
  • Enhanced resolution: nonporous particles and pH-gradient scouting distinguish subtle charge variants
  • Robust reproducibility: minimal RT and area RSD for QC environments
  • Comprehensive characterization: sequence localization of PTMs via online peptide mapping
  • Simplified method development: Buffer Advisor accelerates buffer design and DOE screening

Budoucí trendy a možnosti využití


Emerging directions include:
  • Expansion of multidimensional LC‐MS to antibody–drug conjugates and fusion proteins
  • Further automation and real-time monitoring of manufacturing control strategies using ion-exchange–MS coupling
  • Integration with microfluidics and high-resolution MS for rapid epitope and glycoform analysis
  • Adoption of metal-free flow paths for sensitive biomolecule assays under extreme pH or ionic strength

Závěr


Modern IEX workflows employing nonporous high-efficiency columns, digitally blended gradients via Buffer Advisor, and advanced LC-MS platforms offer robust, high-resolution, and automated solutions for charge variant analysis of complex biotherapeutics. These methods streamline QC, accelerate biosimilar comparability studies, and deepen molecular insights into PTMs influencing drug safety and efficacy.

Reference


1 Farnan D, Moreno GT. Multiproduct High-Resolution Monoclonal Antibody Charge Variant Separations by pH Gradient Ion-Exchange Chromatography. Anal. Chem. 2009;81(21):8846–8857.
2 Liu H, et al. Heterogeneity of Monoclonal Antibodies. J. Pharm. Sci. 2008;97:2426–2447.
3 Vlasak J, Ionescu R. Heterogeneity of Monoclonal Antibodies Revealed by Charge-Sensitive Methods. Curr. Pharm. Biotechnol. 2008;9:468–481.
4 Stoll DR, et al. Direct Identification of Rituximab Main Isoforms by Online Selective Comprehensive Two-Dimensional Liquid Chromatography–Mass Spectrometry. Anal. Chem. 2015;87(22):10948–10955.
5 Stoll DR, et al. Fast and Automated Characterization of Antibody Variants with 4D HPLC/MS. Anal. Chem. 2018;90(4):2119–2125.
6 Sandra K, et al. Automated Protein Separation with pH Gradients Using Agilent Buffer Advisor Software. J. Chromatogr. A. 2020;1621:461075.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mAbs
Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mAbs Application Note Author Abstract Suresh Babu C.V. This Application Note describes the high-resolution separation of charge variants Agilent Technologies India Pvt. Ltd, of innovator and biosimilar rituximab using an Agilent 1260…
Key words
innovator, innovatorbiosimilar, biosimilarrituximab, rituximabvariant, variantvariants, variantsristova, ristovacharge, chargereditux, redituxmau, maucpb, cpbbasic, basicprofiles, profilesacidic, acidicmin, minmabs
Convenient Customization of Your Cation Exchange Analysis
Convenient Customization of Your Cation Exchange Analysis
2021|Agilent Technologies|Applications
Application Note Biopharma Convenient Customization of Your Cation Exchange Analysis Response (mAU) Combining the Agilent 1260 Infinity II Prime Bio LC System, Agilent Buffer Advisor Software, and pH gradients for high-resolving charge variant analysis Author Sonja Schneider Agilent Technologies, Inc.…
Key words
gradient, gradientbuffer, buffercharge, chargeadvisor, advisorgradients, gradientssalt, saltvariants, variantsmonoclonal, monoclonaltrastuzumab, trastuzumabbuffered, bufferedvariant, variantmain, mainphosphate, phosphateresolving, resolvingfarnan
Analysis of Charge Heterogeneity in Rituximab Innovator and Biosimilar Monoclonal Antibodies Using Salt-Gradient Cation Exchange Chromatography
Analysis of Charge Heterogeneity in Rituximab Innovator and Biosimilar Monoclonal Antibodies Using Salt-Gradient Cation Exchange Chromatography Suresh Babu C.V., Salman Lateef Syed, Siji Joseph Agilent Technologies India Pvt. Ltd., Bangalore, India HPLC 2015 PSA-BIO-08 Introduction Results and Discussion Agilent Buffer…
Key words
innovator, innovatorbiosimilar, biosimilarvariants, variantsristova, ristovareditux, redituxmau, mauvariant, variantacidic, acidicrituximab, rituximabmin, minbasic, basicmobile, mobileadvisor, advisormain, mainphase
Charge Variant Analysis - Agilent BioHPLC Columns Application Compendium
Agilent-NISTmAb Charge Variant Analysis Agilent BioHPLC Columns Application Compendium Contents Agilent-NISTmAb Standard (P/N 5191-5744; 5191-5745) was aliquoted from NISTmAb RM 8671 batch. Quality control (QC) testing is performed using Agilent LC-MS system. QC batch release test includes aggregate profile, charge…
Key words
page, pagecontents, contentsback, backvariants, variantscharge, chargeexchange, exchangebio, biobuffer, buffermonoclonal, monoclonalcation, cationvariant, variantcolumn, columnantibodies, antibodiesmab, mabadvisor
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike