Rittun User’s Guide for L-3320 Autosampler
Manuals | 2020 | ECOMInstrumentation
Autosamplers are essential for high-throughput, reproducible and accurate sample introduction in HPLC analyses. The Rittun L-3320 automates injection steps, minimizes human error, and supports complex workflows in pharmaceutical, environmental and industrial laboratories.
The L-3320 User’s Guide aims to describe system features, safe installation, operational procedures, troubleshooting and routine maintenance. It covers installation requirements, self-test routines, injection modes, hardware qualification and daily service protocols.
The autosampler combines precision syringe drives, a multiport injection valve and a programmable XY-Z automation stage. Three injection modes are supported: full-loop, partial-loop fill and µL pickup, each optimized for different sample volumes and precision requirements. Key operational steps include:
Extensive hardware qualification and performance tests demonstrate:
Recommended maintenance intervals and safety checks further support long-term stability.
The L-3320 improves laboratory efficiency by:
Ideal for pharmaceutical QC, environmental monitoring and complex method development workflows.
Emerging developments include integration with micro-flow and ultra-high-pressure systems, coupling to advanced detectors (e.g. MS), and enhanced software-driven optimization using AI algorithms. High-throughput plate formats and cloud-based data analytics will further expand capabilities.
The Rittun L-3320 autosampler offers robust, precise and versatile sample handling for modern HPLC applications. Comprehensive guidance on installation, operation, maintenance and qualification ensures reliable performance and data integrity for diverse analytical challenges.
No external references were cited in this summary.
HPLC
IndustriesManufacturerECOM
Summary
Significance of Topic
Autosamplers are essential for high-throughput, reproducible and accurate sample introduction in HPLC analyses. The Rittun L-3320 automates injection steps, minimizes human error, and supports complex workflows in pharmaceutical, environmental and industrial laboratories.
Goals and Overview
The L-3320 User’s Guide aims to describe system features, safe installation, operational procedures, troubleshooting and routine maintenance. It covers installation requirements, self-test routines, injection modes, hardware qualification and daily service protocols.
Methodology and Instrumentation
The autosampler combines precision syringe drives, a multiport injection valve and a programmable XY-Z automation stage. Three injection modes are supported: full-loop, partial-loop fill and µL pickup, each optimized for different sample volumes and precision requirements. Key operational steps include:
- Sample tray positioning in X–Y directions
- Needle actuation to pierce vial seals
- Syringe aspiration and injection valve switching
- Needle and syringe wash routines to prevent carry-over
Instrumentation
- Rittun L-3320 autosampler
- Solvent organizer (optional vacuum degasser)
- Rittun L-3200 pump series
- Column (e.g. C18, 4.6×150 mm)
- L-3500 UV-Vis detector
- UltraChrom or Rittun CWS data system
Main Results and Discussion
Extensive hardware qualification and performance tests demonstrate:
- Injection accuracy within ±5% and reproducibility (RSD) ≤0.3% for full-loop mode
- Partial-loop and µL pickup modes achieve ≤0.5% and ≤1% RSD respectively
- Minimal cross-contamination (<0.02%) after programmed wash cycles
- Rapid self-check routines ensure correct motor and valve homing
Recommended maintenance intervals and safety checks further support long-term stability.
Benefits and Practical Applications
The L-3320 improves laboratory efficiency by:
- Automating repetitive injections and reducing hands-on time
- Providing flexible volume control and multiple injection strategies
- Ensuring low carry-over and reliable data across large sample sets
Ideal for pharmaceutical QC, environmental monitoring and complex method development workflows.
Future Trends and Possibilities
Emerging developments include integration with micro-flow and ultra-high-pressure systems, coupling to advanced detectors (e.g. MS), and enhanced software-driven optimization using AI algorithms. High-throughput plate formats and cloud-based data analytics will further expand capabilities.
Conclusion
The Rittun L-3320 autosampler offers robust, precise and versatile sample handling for modern HPLC applications. Comprehensive guidance on installation, operation, maintenance and qualification ensures reliable performance and data integrity for diverse analytical challenges.
Reference
No external references were cited in this summary.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Dionex UltiMate 3000 Series Autosampler Column Compartment ACC-3000
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series Autosampler Column Compartment ACC-3000 Operating Instructions (Original Operating Instructions) Revision: 1.4 Date: September 2013 © 2013 Thermo Fisher Scientific Doc No. 4828.3050 UltiMate 3000 Series: ACC-3000 Autosampler Column Compartment Operating Instructions UltiMate 3000 Series:…
Key words
instructions, instructionsoperating, operatingautosampler, autosamplerchromeleon, chromeleonsyringe, syringeneedle, needlepressing, pressingturn, turnwash, washpower, powerloop, loopdes, desagain, againvalve, valvecarousel
Thermo Scientific Dionex UltiMate 3000 Series WPS-3000 Autosamplers (SL, TBSL, RS, TBRS, TXRS)
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series WPS-3000 Autosamplers (SL, TBSL, RS, TBRS, TXRS) Operating Instructions (Original Operating Instructions) Revision: 1.8 Date: September 2013 © 2013 Thermo Fisher Scientific Doc.-No. 4828.2250 UltiMate 3000 Series: WPS-3000 Autosamplers (SL, TBSL, RS, TBRS, TXRS)…
Key words
instructions, instructionsoperating, operatingneedle, needleautosampler, autosamplerwash, washparenthesis, parenthesisseat, seatchromeleon, chromeleoninjection, injectionloop, loopsample, samplepower, powerpressing, pressingdescription, descriptionthermostatting
Thermo Scientific Dionex UltiMate 3000 Series Autosamplers WPS-3000PL (RS) and WPS-3000FC
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series Autosamplers WPS-3000PL (RS) and WPS-3000FC Operating Instructions (Original Operating Instructions) Revision: 1.6 Date: September 2013 © 2013 Thermo Fisher Scientific Inc. Doc No. 4828.2050 UltiMate 3000 Series: WPS-3000PL (RS) and WPS-3000FC Autosamplers Operating Instructions…
Key words
instructions, instructionsoperating, operatingautosampler, autosamplerchromeleon, chromeleonwash, washsyringe, syringevalve, valvepressing, pressingneedle, needleloop, loopsample, sampleyou, youdes, despower, powerdescription
Clarity Control Module SPARK INTEGRITY
2025|DataApex|Manuals
SPARK INTEGRITY Clarity Control Module ENG Code/Rev.: M197/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
spark, sparkintegrity, integrityneedle, needleautosampler, autosamplerdialog, dialogmove, movetray, traycommunication, communicationsyringe, syringeposition, positionclarity, claritystripper, stripperwash, washsetup, setuphomix