ECOM TOY20DAD 800 V SCANNING UV-VIS DETECTOR

Brochures and specifications |  | ECOMInstrumentation
PrepLC
Industries
Manufacturer
ECOM

Summary

Significance of the topic


The ability to monitor multiple wavelengths and full UV-VIS spectra in real time is critical for ensuring sample purity, detecting coeluting species, and optimizing preparative processes. Diode array detectors enhance the analytical versatility of chromatography by providing spectral data that complement quantitative analysis.

Objectives and Overview


This document reviews the performance characteristics of the TOY20DAD 800 V Scanning UV-VIS Detector (part number T20V033X). It aims to summarize its key features, operational parameters, and applications in analytical and preparative liquid chromatography settings.

Instrumentation


  • Detector type: UV-VIS diode array scanning system
  • Wavelength range: 190–800 nm with 256 CCD elements
  • Simultaneous channels: Four wavelengths adjustable in 1 nm increments
  • Spectral scan: 190–800 nm at up to 20 Hz with 1 nm step
  • Light sources: Deuterium lamp (D2) and halogen lamp
  • Analog outputs: Four channels (ranges 0.1–5 AU/V) and digital output (1 V/AU)
  • Interfaces: RS232, USB, LAN, I/O logical signals

Methodology


The detector collects absorbance data via a diode array element, enabling both targeted wavelength monitoring and rapid full-spectrum acquisition. Adjustable time constants (0.1–16 s) allow optimization between sensitivity and response speed. The flow cell design supports analytical and preparative volumes with interchangeable path lengths and high flow rates up to 3000 ml/min.

Main Findings and Discussion


  • Wavelength accuracy and reproducibility: ±1 nm adjustment, ±0.5 nm reproducibility
  • Noise performance: ~5×10⁻⁵ AU at 254 nm (1 s)
  • Drift: ~1×10⁻³ AU/hour at 254 nm
  • Spectral half-width: ~10 nm typical
  • Operational stability: Built-in lamp hour counters for D2 and halogen lamps
  • Physical footprint: Compact design (135×170×340 mm) weighing 4.4 kg

Benefits and Practical Applications


  • Real-time spectral and multi-wavelength monitoring enhances peak purity assessment
  • High-speed scanning supports 3D chromatogram generation for detailed analysis
  • Wide dynamic range and low noise enable trace-level detection
  • Versatility for flash and preparative chromatography due to robust cell design and high flow capacity
  • Flexible control via keyboard, USB, RS232, or LAN and easy maintenance through side-accessible cell

Future Trends and Potential Applications


  • Integration with AI-driven data processing for automated peak identification and purity evaluation
  • Miniaturization and microfluidic flow cells for reduced sample consumption
  • Enhanced spectral resolution using advanced CCD or CMOS sensors
  • Cloud connectivity for remote monitoring and collaborative method development
  • Expansion into hyphenated techniques such as LC-MS with diode array pre-qualification

Conclusion


The TOY20DAD 800 V Scanning UV-VIS Detector offers a robust, flexible solution for both routine analytical and high-throughput preparative chromatography. Its combination of multi-wavelength detection, fast full-spectrum scanning, and user-friendly operation makes it a valuable tool for modern laboratories seeking comprehensive absorbance data.

Reference


  • ECOM spol. s r.o., TOY20DAD 800 V Scanning UV-VIS Detector, Part No. T20V033X Application Note

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
ECOM TOY18DAD V 400, 600, 800 UV-VIS DETECTORS
ECOM TOY18DAD V 400, 600, 800 UV-VIS DETECTORS
|ECOM|Brochures and specifications
TOY18DAD V 400, 600, 800 UV-VIS DETECTORS are UV (UV-VIS) diode array detectors, which allow measuring absorbance of four wavelengths simultaneously in one cell just as measuring of whole spectrum (scan). More wavelengths are used in liquid chromatography to verify…
Key words
wavelengths, wavelengthsanalog, analogfour, fourdigital, digitalabsorbance, absorbanceoutput, outputsimultaneously, simultaneouslyservice, servicecounted, countedmeasuring, measuringdetector, detectorhalogen, halogenmaximal, maximalccd, ccdpower
ECOM TOY18DAD HK TWO CHANNEL UV DETECTOR FOUR CHANNEL UV DETECTOR SCANNING UV DETECTOR
TOY18DAD HK TWO CHANNEL UV DETECTOR FOUR CHANNEL UV DETECTOR SCANNING UV DETECTOR is a standalone UV-VIS diode array detector suited for preparative and flash chromatography in range 200 – 800 nm. It is offered in the following versions: At…
Key words
wavelengths, wavelengthschannel, channeldetector, detectorfour, fourmeasures, measuresscanning, scanningversion, versioninformative, informativeoutputs, outputsanalog, analogdiode, diodedigital, digitaltwo, twooutput, outputsignals
ECOM TOY20DAD 800 VEX SCANNING UV-VIS DETECTOR
ECOM TOY20DAD 800 VEX SCANNING UV-VIS DETECTOR
|ECOM|Brochures and specifications
P/N T20VE33X TOY20DAD 800 VEX SCANNING UV-VIS DETECTOR is an UV (UV-VIS) diode array detector, which allows measuring absorbance of four wavelengths simultaneously in external cell connected by optical cables, just as measuring of whole spectrum (scan). More wavelengths are…
Key words
connectors, connectorsanalog, analogwavelengths, wavelengthsfour, fourdigital, digitalabsorbance, absorbancepanel, panelsignals, signalssimultaneously, simultaneouslysma, smacounted, countedservice, servicemeasuring, measuringdetector, detectorhalogen
ECOM TOY18DAD VEX 400, 600, 800 UV-VIS DETECTORS
ECOM TOY18DAD VEX 400, 600, 800 UV-VIS DETECTORS
|ECOM|Brochures and specifications
TOY18DAD VEX 400, 600, 800 UV-VIS DETECTORS are UV (UV-VIS) diode array detectors, which allow measuring absorbance of four wavelengths simultaneously in external cell connected by optical cables, just as measuring of whole spectrum (scan). More wavelengths are used in…