Quantitation Enhanced Data-Dependent (QED) Scanning of Drinking Water Samples Using EQuan for Pesticide Analysis on a Triple Stage Quadrupole
Applications | 2010 | Thermo Fisher ScientificInstrumentation
Pesticide contamination of drinking water is a global health concern as many compounds are regulated at ultra-trace levels (ng/L). Traditional sample preparation methods such as solid-phase extraction require large volumes, lengthy procedures, and substantial cost. Automating online preconcentration combined with quantitative and confirmatory analysis reduces time, cost, and increases confidence in regulatory compliance.
This study demonstrates a multi-residue assay workflow for 13 pesticides in drinking water using the EQuan large-volume injection system coupled to a triple quadrupole mass spectrometer (TSQ Quantum). The method integrates selected reaction monitoring (SRM) for quantitation with Quantitation Enhanced Data-Dependent (QED) scanning for structural confirmation and library matching.
The experimental setup employed:
The EQuan–SRM method achieved:
The combined EQuan–QED approach:
Emerging directions include:
The integration of online preconcentration with Quantitation Enhanced Data-Dependent scanning on a triple quadrupole platform enables rapid, sensitive, and confirmatory multi-residue pesticide analysis in drinking water. This streamlined workflow meets stringent regulatory requirements and offers significant gains in laboratory efficiency and data confidence.
Sample Preparation, LC/MS, LC/MS/MS, LC/QQQ
IndustriesEnvironmental
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Pesticide contamination of drinking water is a global health concern as many compounds are regulated at ultra-trace levels (ng/L). Traditional sample preparation methods such as solid-phase extraction require large volumes, lengthy procedures, and substantial cost. Automating online preconcentration combined with quantitative and confirmatory analysis reduces time, cost, and increases confidence in regulatory compliance.
Objectives and Study Overview
This study demonstrates a multi-residue assay workflow for 13 pesticides in drinking water using the EQuan large-volume injection system coupled to a triple quadrupole mass spectrometer (TSQ Quantum). The method integrates selected reaction monitoring (SRM) for quantitation with Quantitation Enhanced Data-Dependent (QED) scanning for structural confirmation and library matching.
Methodology and Instrumentation
The experimental setup employed:
- EQuan system with two HPLC pumps (loading and analytical), large-volume autosampler, and dual Hypersil GOLD columns for online preconcentration and separation.
- TSQ Quantum Mass Spectrometer operating in positive electrospray ionization mode. SRM transitions monitored target pesticides, and a reversed energy ramp (RER) QED scan was triggered when SRM signals exceeded predefined thresholds.
- Gradient programs: The loading pump collected 1 mL samples in 0–1.5 min, washed and re-equilibrated the loading column. The analytical pump eluted compounds over a 17 min run at 0.2 mL/min.
- Compounds analyzed include tricyclazole, carbaryl, carbofuran, asulam, diuron, siduron, daimuron, carpropamid, thiodicarb, azoxystrobin, flazasulfuron, bensulfuron-methyl, and halosulfuron-methyl at 0.5–1000 ppt spiking levels.
Key Results and Discussion
The EQuan–SRM method achieved:
- Limits of quantitation down to 1 ppt (pg/mL) for all analytes, with linear calibration from 1–1000 ppt (R2>0.995).
- A 5× lower detection than the lowest maximum residue level (50 ppt for carbofuran).
- QED full-scan MS/MS spectra providing fragment-rich confirmation. Library searches in the built-in NIST format library correctly identified each pesticide as the top hit, even isobaric compounds like diuron and siduron.
Advantages and Practical Applications
The combined EQuan–QED approach:
- Eliminates manual SPE extraction, reducing preparation time from hours or days to minutes.
- Maintains high sensitivity and selectivity for trace-level pesticide quantitation.
- Provides confirmation data in the same run, fulfilling regulatory identification point requirements without additional analyses.
- Offers a flexible library that can be expanded to include user-defined spectra for targeted compounds.
Future Trends and Opportunities
Emerging directions include:
- Broader adoption of large-volume injection and data-dependent scans for other environmental and food matrices.
- Integration with high-resolution mass spectrometry for enhanced specificity.
- Automated library curation and spectral prediction using machine learning to support non-targeted screening.
- Miniaturized and field-deployable systems for real-time water quality monitoring.
Conclusion
The integration of online preconcentration with Quantitation Enhanced Data-Dependent scanning on a triple quadrupole platform enables rapid, sensitive, and confirmatory multi-residue pesticide analysis in drinking water. This streamlined workflow meets stringent regulatory requirements and offers significant gains in laboratory efficiency and data confidence.
References
- European Commission. Commission Decision 2002/657/EC (2002) implementing Council Directive 96/23/EC; Official Journal of the European Communities.
- Japanese Ministry of Health, Labour and Welfare. Regulatory standards for pesticide residues in drinking water (2007); Tokyo, Japan.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific TSQ Quantum Access MAX
2016|Thermo Fisher Scientific|Brochures and specifications
mass spectrometry Thermo Scientific TSQ Quantum Access MAX Innovation, Simplicity, and Value Food Safety Environmental Analysis Drug Discovery and Pharmacokinetics Clinical Research Part of Thermo Fisher Scientific Lit Sheet WhiteAccess Head MAX TSQ Quantum Valu UNSURPASSED PRICE TO PERFORMANCE From…
Key words
tsq, tsqquantum, quantumqed, qedmax, maxaccess, accessquantitation, quantitationresidue, residuescientific, scientificsoftware, softwarethermo, thermoconfirmation, confirmationtracefinder, tracefinderwhiteaccess, whiteaccesslibrary, librarystructural
Analysis of Regulated Pesticides in Drinking Water Using Accela and EQuan
2007|Thermo Fisher Scientific|Applications
Application Note: 391 Analysis of Regulated Pesticides in Drinking Water Using Accela and EQuan Jonathan R. Beck and Charles Yang; Thermo Fisher Scientific, San Jose, CA Introduction Key Words • TSQ Quantum™ • Accela™ LC System • EQuan™ • LC-MS/MS…
Key words
mprl, mprlhplc, hplcaccela, accelaazoxystrobin, azoxystrobinequan, equanflazasulfuron, flazasulfuronbensulfuron, bensulfuronfast, fastsiduron, siduronthiodicarb, thiodicarbtricyclazole, tricyclazolequantum, quantumdiuron, diuroncarbaryl, carbarylcarbofuran
Streamlined Analysis of 400+ Pesticides in a Single Run Using the TSQ Quantum Access MAX Mass Spectrometer and TraceFinder Software
2016|Thermo Fisher Scientific|Applications
Application Note: 525 Streamlined Analysis of 400+ Pesticides in a Single Run Using the TSQ Quantum Access MAX Mass Spectrometer and TraceFinder Software Jia Wang, Charles T. Yang, Jonathan R. Beck, and Dipankar Ghosh; Thermo Fisher Scientific, San Jose, CA…
Key words
ion, iontracefinder, tracefinderquantitation, quantitationpolarity, polarityprecursor, precursorcompound, compoundmethyl, methylmetalaxyl, metalaxylsulfone, sulfoneoxon, oxonqed, qedtriforine, triforinesrm, srmethyl, ethylmin
Simultaneous Analysis of Pesticides in Environment Water using LC-MS
|Shimadzu|Applications
No.C34 SHIMADZU APPLICATION NEWS Table 2 Recoveries of Pesticides No. Pesticide Name Mass Retention Std / Pesticide Resin Solid Phase Column Resin Solid Phase Column Resin Solid Phase Column Ionization Mixture Ion Exchange Water River Water Tap Water Number Time…
Key words
esi, esisolid, solidwater, wateractivated, activatedphase, phaseriver, rivermbc, mbcpyrrolidone, pyrrolidonepesticide, pesticidecopolymer, copolymercolumn, columnsiduron, siduroncarbon, carbonaverage, averagebenomyl