Identification and Quantitation of Microcystins by Targeted Full-Scan LC-MS/MS

Applications | 2012 | Thermo Fisher ScientificInstrumentation
LC/MS, LC/MS/MS, LC/IT
Industries
Environmental
Manufacturer
Thermo Fisher Scientific

Summary

Significance of the Topic


Monitoring cyanobacterial toxins in water is critical to safeguard public health and ensure compliance with regulatory guidelines. Microcystins, a family of cyclic heptapeptides produced by cyanobacteria, pose serious hepatotoxic and potentially carcinogenic risks. Sensitive and unambiguous detection methods are essential to detect trace levels of these toxins in drinking and recreational waters.

Aims and Study Overview


This application note describes the development of a simple, sensitive and robust targeted full-scan LC-MS/MS method for definitive identification and quantitation of three common microcystin variants (MC-RR, MC-YR and MC-LR) in water. The study demonstrates analytical performance over a broad concentration range and evaluates method precision, accuracy and applicability to real water samples.

Methodology and Instrumentation


  • Sample Preparation: Standards of MC-RR, MC-YR and MC-LR were mixed at 5 µg/mL and serially diluted to generate calibration levels from 0.025 to 50 µg/L.
  • Instrumental Setup: Separation was performed on a Thermo Scientific UltiMate 3000 x2 Dual RSLC with Acclaim PepMap100 C18 column (150 × 1.0 mm, 3 µm) and guard cartridge. Mobile phases: water (0.1% formic acid) and acetonitrile (0.1% formic acid). Gradient flow at 150 µL/min and column temperature of 40 °C.
  • Mass Spectrometry: A Thermo Scientific Velos Pro dual-pressure linear ion trap was operated in positive ESI mode. Targeted full-scan MS/MS acquisitions used precursor m/z windows for each toxin ([M+2H]2+ m/z 520 for MC-RR; [M+H]+ m/z 1045 for MC-YR; [M+H]+ m/z 995 for MC-LR) over defined m/z ranges. Collision energy set at 35% with 2 Da isolation window.

Main Results and Discussion


  • Structural Confirmation: Full-scan CID MS/MS spectra enabled clear identification of each congener based on characteristic fragment ions (e.g., Adda-derived and amino acid fragments) and resolved closely eluting MC-YR and MC-LR peaks.
  • Quantitative Performance: Excellent linearity (R2 > 0.9986) from 0.05 to 50 µg/L; LOD 0.025 µg/L and LOQ 0.05 µg/L for all three microcystins. Calibration curve coefficients of determination: MC-RR 0.9986, MC-YR 0.9994, MC-LR 0.9994.
  • Precision and Accuracy: Peak area RSDs over five replicates were below 7% for MC-LR, below 11% for MC-YR, and below 6% for MC-RR at concentrations ≥0.10 µg/L (RSD 16% at LOQ). Retention time precision ≤0.3% RSD. QC accuracy >94% at 0.5 and 5 µg/L.
  • Matrix Testing: No microcystins detected in tap water, filtered water or surface pond water samples, demonstrating method suitability for environmental monitoring.

Benefits and Practical Applications


This targeted full-scan LC-MS/MS approach combines the specificity of MS/MS structural confirmation with high sensitivity and broad dynamic range. It eliminates the need for compound-dependent parameter optimization, streamlines workflow, and supports regulatory compliance for water quality monitoring in research, industrial QA/QC and public health laboratories.

Future Trends and Potential Applications


Emerging needs for comprehensive cyanotoxin surveillance may drive adoption of full-scan high-resolution MS techniques, multiplexed workflows for simultaneous toxin classes, and automated data processing using advanced software or AI-driven algorithms. Integration with on-site sampling platforms and rapid screening kits could further enhance monitoring frequency and coverage.

Conclusion


The developed LC-MS/MS method on a Velos Pro ion trap delivers sensitive, selective and reproducible identification and quantitation of MC-RR, MC-YR and MC-LR at levels well below WHO guidelines. Its robust performance and streamlined full-scan acquisition support reliable routine analysis of microcystins in various water matrices.

Reference


  • Chorus I, Bartram J, eds. Toxic cyanobacteria in water: A guide to their public health consequences, monitoring and management. WHO/E&FN Spon; 1999.
  • IARC Working Group on the Evaluation of Carcinogenic Risks to Humans. Ingested nitrate and nitrite and cyanobacterial peptide toxins. IARC Monogr Eval Carcinog Risks Hum. 2010;94:1–477.
  • World Health Organization. Guidelines for Drinking-water Quality, 3rd ed. Vol. 1 Recommendations. WHO; 2004.
  • ISO 20179:2005. Water quality—Determination of microcystins—SPE and HPLC-UV method. International Standards Organization; 2005.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Identification and Quantitation of Microcystins by Targeted Full-Scan LC-MS/MS
Terry Zhang, Reiko Kiyonami, Leo Wang and Guifeng Jiang Thermo Fisher Scientific, San Jose, CA, USA Key Words Velos Pro, UltiMate, Water Analysis, Cyanobacteria, Microcystin Goal Develop a simple and sensitive LC-MS method for definitive identification and quantitation of microcystins…
Key words
microcystins, microcystinsidentification, identificationvelos, velosscan, scanenable, enablefull, fullguideline, guidelinemsn, msnquantitation, quantitationmicrocystin, microcystintargeted, targetedprovisional, provisionalnomenclature, nomenclaturewho, whoamino
Identification of Unknown Microcystins in Alberta Lake Water
Identification of Unknown Microcystins in Alberta Lake Water Application Note Environmental Authors Abstract Ralph Hindle Detection, characterization, and tentative identification of very low levels of Vogon Laboratory Services Ltd. unknown microcystins in lake water are possible in the absence of…
Key words
counts, countsmicrocystin, microcystinmicrocystins, microcystinsunknown, unknownhtyr, htyralberta, albertaarginine, argininelake, lakemass, massleucine, leucinetof, tofcalibrator, calibratoraccurate, accurateacft, acftdesmethylation
Fast and Accurate Determination of Algal Toxins in Water Using Online Preconcentration and UHPLC-Orbitrap Mass Spectrometry
Jaewon Choi,1 Je-Heon Jang,1 Jennifer Massi,2 Jonathan Beck2 Water Analysis & Research Center, K water, Daejeon 306-711, Korea 2 Thermo Fisher Scientific, San Jose, CA, USA 1 Key Words EQuan, Exactive, Orbitrap, algal toxins, cyanobacteria, water analysis, online concentration Goal…
Key words
microcystin, microcystinnodularin, nodularintoxins, toxinsonline, onlinepreconcentration, preconcentrationwater, wateralgal, algalmicrocystins, microcystinscyanobacteria, cyanobacteriamethod, methodpql, pqlquantitation, quantitationcyanotoxins, cyanotoxinshypersil, hypersilamount
Analysis of Microcystins using LS-MS (No. 2)
LC-MS Application Data Sheet No. 049 Analysis of Microcystins using LS-MS (No. 2) Microcystins (Fig. 1) are liver toxins (carcinogenic promoters) produced by blue-green algae (cyanobacteria) in outbreaks of eutrophication. A 2001 revision of Japanese Drinking Water Test Method in…
Key words
microcystin, microcystinmicrocystins, microcystinstenth, tenthcdl, cdlvoltage, voltagecooh, coohconc, concmethyldehydroalanine, methyldehydroalaninearray, arraydrinking, drinkingpromoters, promoterscyanobacteria, cyanobacteriaarea, areaalgae, algaechromatograms