Forensic Screening for Drugs in Urine Using High-Resolution MS/MS Spectra and Simplified High-Performance Screening Software
Applications | 2015 | Thermo Fisher ScientificInstrumentation
Forensic screening of drugs in urine is essential for criminal investigations, health monitoring, and regulatory compliance. Comprehensive screening methods must detect a broad spectrum of substances with high sensitivity, specificity, and throughput to support toxicological casework and routine monitoring.
This study evaluated the performance of a hybrid quadrupole-Orbitrap mass spectrometer coupled with simplified screening software for detection and quantitation of over 300 compounds in human urine. Goals included establishing detection limits, assessing software identification accuracy, and demonstrating application in diluted urine samples.
Most of the 300 screened compounds yielded detection limits at or below 10 ng/mL using primary software processing. Adding isotopic pattern matching improved identification confidence but raised detection thresholds slightly. Tests with spiked blank and authentic positive urine samples confirmed reliable identification of drugs of abuse, therapeutic agents, and environmental toxins. The software review interface displayed reconstructed chromatograms, library match scores, and isotopic pattern comparisons to streamline data validation.
Expanding high-resolution spectral libraries and integrating machine learning algorithms will enhance detection of emerging psychoactive substances. Automation of sample preparation and real-time data processing could enable point-of-care toxicology. Cloud-based library sharing and collaborative platforms may accelerate method development and standardization across laboratories globally.
The Q Exactive Focus mass spectrometer combined with ToxFinder software delivers a robust high-performance platform for forensic urine screening. It achieves low limits of detection, streamlined workflows, and extensive compound coverage in a single 10-minute analysis, improving laboratory efficiency and supporting accurate forensic and clinical decision-making.
Software, LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesForensics
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Forensic screening of drugs in urine is essential for criminal investigations, health monitoring, and regulatory compliance. Comprehensive screening methods must detect a broad spectrum of substances with high sensitivity, specificity, and throughput to support toxicological casework and routine monitoring.
Objectives and Study Overview
This study evaluated the performance of a hybrid quadrupole-Orbitrap mass spectrometer coupled with simplified screening software for detection and quantitation of over 300 compounds in human urine. Goals included establishing detection limits, assessing software identification accuracy, and demonstrating application in diluted urine samples.
Methodology
- Sample Preparation: Centrifuged urine was spiked with tolbutamide-d9 internal standard, diluted 30-fold, and analyzed without hydrolysis.
- Chromatography: Gradient HPLC on an Accucore PFP column (2.6 µm, 100 × 2.1 mm) using 10 mM ammonium formate in water and methanol. Elution from 5 to 100 % methanol in 6 min; total runtime 10 min.
- Mass Spectrometry: Q Exactive Focus in full-scan data-dependent MS² mode. Full-scan resolution 70 000 for positive/negative ions; MS² at 17 500 resolution triggered by an inclusion list.
- Data Analysis: ToxFinder software matched accurate mass, retention time, MS² spectra, and optional isotopic pattern to proprietary libraries covering drugs of abuse, pharmaceuticals, and environmental toxins.
Used Instrumentation
- Q Exactive Focus hybrid quadrupole-Orbitrap mass spectrometer
- UltiMate 3000 RSLC pump with OAS autosampler
- Ion Max HESI II source
- Thermo Scientific Accucore PFP column
- ToxFinder screening software
Main Results and Discussion
Most of the 300 screened compounds yielded detection limits at or below 10 ng/mL using primary software processing. Adding isotopic pattern matching improved identification confidence but raised detection thresholds slightly. Tests with spiked blank and authentic positive urine samples confirmed reliable identification of drugs of abuse, therapeutic agents, and environmental toxins. The software review interface displayed reconstructed chromatograms, library match scores, and isotopic pattern comparisons to streamline data validation.
Benefits and Practical Applications
- Simplified dilute-and-shoot protocol reduces sample preparation time and cost.
- High-resolution Orbitrap detection ensures accurate mass measurements and specificity.
- Intuitive ToxFinder software offers rapid method setup, automated library searching, and customizable reporting for LIMS integration.
- Comprehensive coverage of both positive and negative ionizing compounds supports broad forensic and clinical toxicology applications.
Future Trends and Applications
Expanding high-resolution spectral libraries and integrating machine learning algorithms will enhance detection of emerging psychoactive substances. Automation of sample preparation and real-time data processing could enable point-of-care toxicology. Cloud-based library sharing and collaborative platforms may accelerate method development and standardization across laboratories globally.
Conclusion
The Q Exactive Focus mass spectrometer combined with ToxFinder software delivers a robust high-performance platform for forensic urine screening. It achieves low limits of detection, streamlined workflows, and extensive compound coverage in a single 10-minute analysis, improving laboratory efficiency and supporting accurate forensic and clinical decision-making.
References
- Marta Kozak; Kristine Van Natta; Thermo Fisher Scientific; Application Note 616: Forensic Screening for Drugs in Urine; 2015.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Evaluation of Ultra High Resolution Mass Spectrometer in Targeted Forensic Screening Method for Urine Analysis in Comparison to Immunoassay and GC-MS Techniques
|Thermo Fisher Scientific|Posters
Evaluation of Ultra High Resolution Mass Spectrometer in Targeted Forensic Screening Method for Urine Analysis in Comparison to Immunoassay and GC-MS Techniques Marta Kozak1, Bénédicte Durez1, Maggie Lee2, Ernest Wang2, Cristina Stefan2 1Thermo Fisher Scientific, San Jose, CA; 2 Clinical…
Key words
glucuronide, glucuronidetrazodone, trazodonenicotine, nicotinecodeine, codeinenor, norbupriopion, bupriopionketamine, ketamineeddp, eddpdoxylamine, doxylaminemethadone, methadoneimmunoassay, immunoassaytramadol, tramadolglucuronides, glucuronidespropranolol, propranololacetaminophen
Clinical research and forensic toxicology - Application Compendium
2007|Thermo Fisher Scientific|Guides
Endocrine Drugs of Abuse Pain Management Therapeutic Drug Analysis Clinical research and forensic toxicology Application Compendium Endocrine Analysis for Clinical Research* Therapeutic Drug Analysis for Clinical Research Drugs of Abuse Analysis for Forensic Toxicology** Pain Management Drug Analysis for Forensic…
Key words
scientific, scientificthermo, thermourine, urinemass, massprelude, preludesplc, splctsq, tsqafrica, africawere, wereturboflow, turboflowarea, areamethod, methodexactive, exactiveforensic, forensicsample
Ethanol Metabolites by Paper Spray Ionization: Method Development in Negative Ion Mode
2016|Thermo Fisher Scientific|Posters
Overview Methods Mass Spectrometry A commercially available Velox 360™ paper spray system (Fig. 1, Prosolia, Inc., Indianapolis, IN) that uses Velox Sample Cartridges (VSC) was coupled to a Thermo Scientific™ Q Exactive™ Focus MS or a Thermo Scientific™ Q Exactive™…
Key words
urine, urinepaper, paperets, etsspray, sprayetg, etgarearatio, arearatioethanol, ethanolionization, ionizationethyl, ethylmetabolites, metabolitesglucuronide, glucuronideforspiked, forspikedrelativeabundance, relativeabundancemass, masssulfate
Thermo Scientific Q Exactive Focus Orbitrap LC-MS/MS System
2016|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific Q Exactive Focus Orbitrap LC-MS/MS System HRAM Selectivity with Confidence For Routine Applications Proven • Durable • Affordable Transforming Routine Quantitation Designed for routine applications, the Thermo Scientific™ Q Exactive™ Focus hybrid quadrupole-Orbitrap mass spectrometer democratizes high resolution…
Key words
orbitrap, orbitrapquantitation, quantitationhram, hramscreening, screeningsieve, sievetracefinder, tracefindersoftware, softwareglucoronide, glucoronidedata, dataproven, provencodeine, codeinecefalexin, cefalexinconfirmation, confirmationtargeted, targetedcompound