Thermo Scientific Dionex Omni Coulometric Electrochemical Cell - PRODUCT SPECIFICATIONS

Brochures and specifications | 2016 | Thermo Fisher ScientificInstrumentation
HPLC
Industries
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


Coulometric detection plays a crucial role in modern liquid chromatography by enabling in-line removal of interfering substances from the mobile phase or sample matrix and by chemically converting target analytes to improve detection selectivity and sensitivity. This approach is widely applied in pharmaceutical analysis, environmental monitoring, food safety testing, and biochemical research.

Objectives and Study Overview


This summary introduces the Thermo Scientific™ Dionex™ Omni 6020RS Coulometric Electrochemical Cell designed for seamless integration with UHPLC/HPLC systems and the ECD-3000RS detector. The aim is to highlight its design features, operational capabilities, and compatibility with existing electrochemical detection modules, emphasizing its role as a safeguard and enhancer for challenging analyses.

Methodology and Instrumentation


The Omni 6020RS cell is based on a single-channel, high-surface-area flow-through working electrode that supports efficient analyte conversion. Key specifications include:
  • Working electrode material: microporous graphitic carbon
  • Potential range: –300 to +1100 mV vs. palladium reference
  • Maximum operating pressure: 620 bar (9000 psi)
  • Internal volume: 5.7 µL
  • Wetted materials: PEEK, porous graphite, palladium, PTFE
  • Fluid connections: 10-32 female ports compatible with BioViper™ MP35N alloy or NanoViper™ fused-silica liners
  • Operating temperature: 10–45 °C, 18–80 % RH (non-condensing)
  • Solvent compatibility: typical reversed- and normal-phase solvents

The cell is maintenance-free, plug-and-play, and optimized for both HPLC and UHPLC. It can operate independently or in concert with dual-channel coulometric (6011RS) or amperometric (6041RS) analytical cells using the DC potentiostat module of the UltiMate 3000 ECD system.

Key Results and Discussion


When integrated with the ECD-3000RS detector, the 6020RS cell provides:
  • Real-time protection of the detection system by removing mobile phase impurities
  • Elimination of unwanted matrix effects to stabilize baselines
  • Enhanced analyte selectivity through targeted electrochemical conversion
  • Capability to multiplex sensors for simultaneous multi-analyte detection

These features deliver improved sensitivity, reproducibility, and robustness in demanding analytical workflows.

Benefits and Practical Applications


The Omni 6020RS coulometric cell offers:
  • Continuous matrix cleanup for greater analytical confidence
  • Versatile deployment as a standalone sensor or in multi-sensor arrays
  • Simplified operation with no routine maintenance requirements
  • Broad compatibility with chromatographic conditions and solvent systems

Such versatility makes it ideal for pharmaceutical quality control, environmental analysis, food and beverage testing, and biochemical assays.

Future Trends and Opportunities


Emerging directions include the development of advanced electrode coatings for extended selectivity and lifespan, further miniaturization for micro- and nano-flow applications, and integration with automated data-analysis platforms. Combining electrochemical cells with orthogonal detection techniques (e.g., mass spectrometry or spectroscopy) could enable comprehensive multi-modal analyses and real-time monitoring in process analytical technology (PAT).

Conclusion


The Thermo Scientific Dionex Omni 6020RS coulometric cell represents a robust, maintenance-free solution for enhancing electrochemical detection in HPLC and UHPLC systems. Its high performance, broad compatibility, and ease of use advance analytical capabilities across pharmaceutical, environmental, and biotechnological applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Thermo Scientific UltiMate 3000 Series Electrochemical Detector ECD-3000RS Operating Instructions
Thermo Scientific UltiMate 3000 Series Electrochemical Detector ECD-3000RS Operating Instructions (Original Operating Instructions) Revision: 2.1 Date: October 2019 © 2019 Thermo Fisher Scientific Inc. Doc. No. 4820.7001 UltiMate 3000 Series: ECD-3000RS Electrochemical Detector Page II Operating Instructions UltiMate 3000 Series:…
Key words
instructions, instructionsoperating, operatingpotentiostat, potentiostatcell, cellelectrochemical, electrochemicaldetector, detectorcells, cellsfilter, filterdes, despulse, pulseelectrode, electrodechromeleon, chromeleonpotential, potentialles, lescoulometric
Thermo Scientific Dionex UltiMate 3000 Electrochemical Detector - PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS Thermo Scientific Dionex UltiMate 3000 Electrochemical Detector For sensitive and selective measurement in complex matrices Thermo Fisher Scientific now offers the benefits of UHPLC to electrochemical detection while maintaining compatibility with HPLC – establishing a new standard for…
Key words
electrochemical, electrochemicalpotentiostat, potentiostatpulse, pulsesupported, supportedchoose, choosechannel, channelpad, padordered, orderedmodule, modulebelow, belownoise, noiseluidic, luidiclist, listseparately, separatelyfiltering
Chromatography for Neuroscience Applications Notebook
Chromatography for Neuroscience Applications Notebook
2016|Thermo Fisher Scientific|Guides
Table of Contents The Liquid Chromatography System Chromatography for Neuroscience Analysis Turnkey Solutions for Neuroscience Analysis Multiple Neurochemical Profiling Monoamines and Metabolites Neuroactive Amino Acids Aminothiols Acetylcholine Free D-Serine and D-Aspartic Acid Recommended System Configurations Peer Review Journal References Chromatography…
Key words
neuroscience, neuroscienceneurochemical, neurochemicalmonoamines, monoaminesaminothiols, aminothiolsneuroactive, neuroactiveacetylcholine, acetylcholinepeer, peerturnkey, turnkeyaspartic, asparticserine, serinejournal, journalamino, aminochromatography, chromatographyconfigurations, configurationsprofiling
Thermo Scientific Dionex UltiMate 3000 Electrochemical Detector
Thermo Scientific Dionex UltiMate 3000 Electrochemical Detector
2016|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific Dionex UltiMate 3000 Electrochemical Detector Redefining electrochemical detection Sensitivity • Selectivity • Optimized Performance Higher sensitivity greater selectivity The Thermo Scientific™ Dionex™ UltiMate™ 3000 electrochemical detector, designed by the pioneers of coulometric electrochemical detection, delivers state-of-the-art sensor technologies…
Key words
smartchip, smartchipelectrochemical, electrochemicaloctopamine, octopaminesensors, sensorsepinephrine, epinephrinesensor, sensorcoulometric, coulometricamperometric, amperometriccabling, cablingelectrodes, electrodestyramine, tyraminefemtogram, femtogramnorepinephrine, norepinephrinedopamine, dopaminenanoviper
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike