LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Installation Instruction for ProfIC Vario 15 Anion

Manuals |  | MetrohmInstrumentation
Ion chromatography
Industries
Manufacturer
Metrohm

Summary

Importance of the topic

IC is a fundamental separation technique for monitoring inorganic anions in environmental, industrial, and research applications. The Metrohm ProfIC Vario 15 Anion system combines sequential suppression with the intelligent Partial Loop Technique (MiPT) to automate routine analyses, enabling high sensitivity and precision in quantifying anions from µg/L to mg/L without manual dilution.

Aims and overview of the bulletin

This document provides a detailed, step-by-step procedure for installing and configuring the ProfIC Vario 15 Anion system and its software. Key objectives include:
  • Setting up the hardware components for automatic anion determination
  • Installing and configuring MagIC Net software for instrument control
  • Establishing the injection and calibration strategy using MiPT

Methodology and instrumentation

Installation and configuration cover both hardware and software aspects:
  • Hardware assembly of the 940 Professional IC Vario, 858 Professional Sample Processor, and 800 Dosino
  • Connection of capillaries, suppressor, and detector using MiPT accessories
  • Software installation of MagIC Net 3.0 and automatic recognition of devices via USB
  • Definition of needle positions, solution properties, and rack configuration in MagIC Net
  • Purge and conditioning of the suppressor and separation column prior to analysis
  • Method creation: single-standard multipoint calibration by varying injection volumes

Used Instrumentation

  • 940 Professional IC Vario One/SeS/PP with Conductivity Detector (2.850.9010)
  • 858 Professional Sample Processor (2.858.0010) with Swing Head and Liquid Handling Station
  • 800 Dosino (2.800.0010) for solution delivery
  • MiPT kit including suppressor cartridges (MSM-HC, MSM-LC), Metrosep A and C columns
  • MagIC Net software version 3.0
  • Optional 941 Eluent Production Module for automated eluent generation

Main results and discussion

An exemplary chromatographic separation of seven anions (F⁻, Cl⁻, NO₂⁻, Br⁻, NO₃⁻, SO₄²⁻, PO₄³⁻) was performed:
  • Injection volume: 8 µL; concentration: 2 mg/L per analyte
  • Calibration range: 1–50 mg/L using a quadratic fit; correlation coefficients ≥0.99994
  • Precision: 10 replicate injections at 1 mg/L yielded relative standard deviations below 1% for all ions

Benefits and practical applications of the method

  • Fully automated workflow reduces manual intervention and error
  • No prior dilution needed through MiPT, streamlining sample preparation
  • Single-standard multipoint calibration saves time and reagents
  • Reliable performance for QA/QC, environmental monitoring, and process control

Future trends and opportunities

Emerging developments include:
  • On-line eluent generation for continuous, unattended operation
  • Advanced suppression technologies to lower detection limits
  • Integration of AI-driven diagnostics for predictive maintenance
  • Modular and hyphenated configurations coupling IC with sample-preparation and spectroscopic detectors

Conclusion

The ProfIC Vario 15 Anion system with MiPT offers a robust, high-throughput solution for anion analysis. Its automated hardware and software integration deliver consistent, precise results while minimizing manual handling and reagent use.

Reference

No external literature references were provided in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Installation Instruction for ProfIC Vario 14 Anion
Application Bulletin 389 Installation Instruction for ProfIC Vario 14 Anion ProfIC Vario 14 Anion is a Professional IC Vario system for the fully automatic determination of anions with sequential suppression using the Metrohm intelligent Pick-up Technique (MiPuT). MiPuT is the…
Key words
msm, msmdosino, dosinorinsing, rinsingmcs, mcssuppressor, suppressorregeneration, regenerationconnected, connectedpick, pickrotor, rotorcapillaries, capillariesconnection, connectionstation, stationlabeled, labeledplease, pleasecapillary
Installation instruction for ProfIC Vario 15 AnCat
Application Bulletin 394 Installation instruction for ProfIC Vario 15 AnCat ProfIC Vario 15 AnCat is a Professional IC Vario system for the fully automatic determination of anions with sequential suppression and cations. The Metrohm intelligent Partial Loop Technique (MiPT) is…
Key words
msm, msmprocessor, processordosino, dosinomcs, mcsrinsing, rinsingsuppressor, suppressorregeneration, regenerationstation, stationcation, cationrotor, rotorplease, pleasedetector, detectorconnect, connectconnected, connectedconnection
Installation Instruction for ProfIC Vario 5 Anion
Application Bulletin 373 Installation Instruction for ProfIC Vario 5 Anion ProfIC Vario 5 – Anion is a Professional IC Vario system with variable sample preconcentration for trace analysis of anions or cations with sequential suppression. With the «ProfIC Vario 5»,…
Key words
msm, msmcapillary, capillarydosino, dosinorinsing, rinsingregeneration, regenerationsuppressor, suppressorprofic, proficconnected, connectedrotor, rotoroutlet, outletprocessor, processorlabeled, labeledcapillaries, capillariesvario, varioplease
Installation Instruction for ProfIC Vario 9 Anion
Application Bulletin 383 Installation Instruction for ProfIC Vario 9 Anion ProfIC Vario 9 – Anion is a Professional IC Vario system with variable sample preconcentration and Matrix Elimination for trace analysis of anions. With the «ProfIC Vario 9», concentrations down…
Key words
msm, msmrinsing, rinsingprocessor, processordosino, dosinocapillary, capillaryconnected, connectedfluoride, fluorideprofic, proficnitrite, nitriteoutlet, outletbromide, bromidelabeled, labeledcapillaries, capillariesvario, varionitrate
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike