Active & iterative data-dependent reinjection logic for maintaining throughput, uptime, and consistency in triple quadrupole LC/MS analysis

Posters | 2022 | Agilent Technologies | ASMSInstrumentation
Software, LC/MS, LC/MS/MS, LC/QQQ
Industries
Other
Manufacturer
Agilent Technologies

Summary

Importance of the Topic



Triple quadrupole LC/MS analysis is central to high throughput targeted quantitation in pharmaceutical QA QC, pesticide monitoring, food safety testing, and clinical bioanalysis. Maintaining consistent accuracy, preventing carryover, and minimizing downtime are essential for large batch sample processing and continuous operation.

Objectives and Study Overview



This study introduces iReflex, an intelligent data dependent reinjection logic within Agilent MassHunter 12 paired with the 6475 triple quadrupole LC/MS. The aim is to demonstrate automated workflows that detect sample issues in real time and perform conditional reinjections to preserve data quality and throughput across three scenarios: carryover detection, out of calibration range events, and fast screening confirmation.

Methodology and Instrumentation



Measurements were conducted using an Agilent 6475 triple quadrupole LC/MS system (model G6475A) coupled to an Infinity II 1290 HPLC, controlled by MassHunter 12. Samples, blanks, and calibration standards were acquired in MRM mode. Data analysis methods contained logical conditions based on signal abundance or concentration thresholds that trigger automatic reinjection commands. A unified acquisition and data analysis parameter set generated worklists incorporating iReflex logic.

Key Results and Discussion



  • Carryover Workflow automatically detects sample contamination by monitoring blank injections. Upon exceeding threshold, up to n blank reinjections are inserted and can pause the run to prevent downstream sample contamination.
  • Calibration Range Workflow identifies analytes above the upper limit of quantitation. It appends a blank followed by a reinjection with reduced volume, bringing concentration within calibration limits without manual intervention.
  • Fast Screening Workflow flags presumptive positives in rapid methods and inserts or appends confirmation injections using longer or alternative LC methods. Optional blank insertions and QC checks maintain integrity between tiers.

Benefits and Practical Applications



  • Enhanced throughput by automating reinjection decisions and reducing manual oversight.
  • Improved data consistency through real time monitoring and reflex actions.
  • Reduced sample waste and contamination by targeted blank injections.
  • Streamlined reporting with combined tiered analysis outputs.

Future Trends and Potential Applications



Advances may include integration of machine learning for adaptive threshold setting, cloud based LIMS connectivity for real time decision making, extension of reflex logic to other MS platforms, and dynamic method optimization for evolving analytical challenges.

Conclusion



iReflex within the Agilent 6475 LC/MS and MassHunter 12 offers an automated, intelligent reinjection framework that maximizes throughput and data quality. By concurrently executing carryover prevention, calibration enforcement, and fast screening confirmation, laboratories can achieve robust, continuous operation aligned with SOP guidelines.

Reference



  1. Shah D, Rennie EE, Seymour L, Sharma M, Pyke JS, Batoon P. Active and iterative data dependent reinjection logic for maintaining throughput, uptime, and consistency in triple quadrupole LC MS analysis. ASMS 2022 Poster MP326. 2022

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Advances in Mass Spectrometry Instrument Intelligence
Advances in Mass Spectrometry Instrument Intelligence
2022|Agilent Technologies|Brochures and specifications
Advances in Mass Spectrometry Instrument Intelligence Overview Table of Contents There is a global trend towards more self‑aware, intelligent tools meant to make life easier. The field of liquid chromatography/mass spectrometry is no different with the move to automate difficult…
Key words
passed, passedresult, resultuptime, uptimemaximize, maximizereflex, reflexreinjection, reinjectiondevelop, developfaster, fasteroptimization, optimizationensure, ensureconfidence, confidencechecktune, checktuneoverview, overviewintelligent, intelligention
Boost Efficiency and Productivity with Instrument Intelligence and Workflow Automation
Technical Overview Boost Efficiency and Productivity with Instrument Intelligence and Workflow Automation For LC/TQ, LC/TOF, and LC/Q-TOF workflows Introduction Ever-increasing pressure for laboratories to minimize operating costs while maximizing output demands innovative approaches to their daily work. Recent developments in…
Key words
reflex, reflexworkflows, workflowsintelligent, intelligentappend, appendemf, emfworkflow, workflowinstrument, instrumentswarm, swarmworklist, worklistlogic, logicmaintenance, maintenancereinjections, reinjectionsautotune, autotunefeedback, feedbackstatus
Intelligent Reflex Fast Screening for Drugs in Urine
Intelligent Reflex Fast Screening for Drugs in Urine
2023|Agilent Technologies|Applications
Application Note Forensic Toxicology Intelligent Reflex Fast Screening for Drugs in Urine Data-dependent reinjection logic for screening and confirmation of presumptive positives using the intelligent reflex fast screening function in MassHunter acquisition software Agilent 6495D triple quadrupole LC/MS system Agilent…
Key words
reflex, reflexreinjection, reinjectionscreening, screeningintelligent, intelligentconfirmatory, confirmatorypresumptive, presumptiveacquisition, acquisitionfast, fastlogic, logicmasshunter, masshunterintelligence, intelligencemethod, methodexperiment, experimenttime, timeposition
Intelligent Reflex Fast Screening for Drugs in Urine: data-dependent reinjection logic for screening and confirmation of presumptive positives
Poster Reprint ASMS 2023 Poster number TP 458 Intelligent Reflex Fast Screening for Drugs in Urine: data-dependent reinjection logic for screening and confirmation of presumptive positives Lee Bertram, Patrick Batoon Agilent Technologies Inc., Santa Clara, CA Introduction Intelligent reflex is…
Key words
screening, screeningconfirmatory, confirmatoryreflex, reflexreinjection, reinjectionpresumptive, presumptivemethod, methodintelligent, intelligentposition, positionvial, viallogic, logictemperature, temperaturepositive, positivehydrocodone, hydrocodoneexperiment, experimentpositives
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike