Analysis of Organic Light Emitting Diode Materials Using a Novel Single Quadrupole LC/MS
Posters | 2022 | Shimadzu | ASMSInstrumentation
Organic light emitting diode (OLED) materials play a pivotal role in modern display and lighting technologies. Precise characterization of these compounds and their impurities is essential for ensuring device performance, longevity, and safety. Advanced analytical approaches enable rapid quality control and support the development of high-quality OLED components.
This study demonstrates the application of a novel single quadrupole LC/MS system (LCMS-2050) coupled with an HPLC unit (Nexera X3) for analysis of OLED materials. The goals include confirming molecular weights of target compounds, detecting low-level impurities, and evaluating the effectiveness of a heated dual ion source (DUIS) combining ESI and APCI in a single measurement.
The analysis employed the following configuration:
Seven representative OLED analytes were prepared at 0.1 mg/mL in THF/methanol: coronene, TAPC, CBP, DPEPO, rubrene, TCTA, and 9,10-diphenylanthracene.
Mass spectra of the principal PDA peaks confirmed monoisotopic masses consistent with the target compounds (e.g., coronene m/z 300.0939 [M+H]+, TAPC m/z 626.3661). The DUIS source effectively ionized both polar and low-polarity species, eliminating the need for separate analyses. Impurity profiling in TAPC revealed ultra-trace byproducts, with retention times and m/z values catalogued for nine impurity peaks. Combined PDA and MS chromatograms facilitated reliable peak assignment and impurity identification.
The integrated single quadrupole LC/MS approach offers:
These capabilities support routine testing in research, manufacturing QA/QC, and regulatory compliance.
Advancements may include coupling DUIS-enabled quadrupole systems with high-throughput HPLC for inline process monitoring. Expansion to other low-polarity organic materials and integration with data-driven predictive models will further enhance real-time decision making in material development. Potential improvements in source design and software algorithms could enable semi-quantitative impurity profiling and automated reporting.
The study validates the LCMS-2050 single quadrupole with DUIS as a robust platform for comprehensive analysis of OLED materials and impurities. It delivers accurate mass confirmation, broad ionization coverage, and streamlined workflows, making it a valuable tool for both research and industrial quality assurance.
HPLC, LC/MS, LC/SQ
IndustriesMaterials Testing
ManufacturerShimadzu
Summary
Significance of the Topic
Organic light emitting diode (OLED) materials play a pivotal role in modern display and lighting technologies. Precise characterization of these compounds and their impurities is essential for ensuring device performance, longevity, and safety. Advanced analytical approaches enable rapid quality control and support the development of high-quality OLED components.
Objectives and Overview
This study demonstrates the application of a novel single quadrupole LC/MS system (LCMS-2050) coupled with an HPLC unit (Nexera X3) for analysis of OLED materials. The goals include confirming molecular weights of target compounds, detecting low-level impurities, and evaluating the effectiveness of a heated dual ion source (DUIS) combining ESI and APCI in a single measurement.
Methodology and Instrumentation
The analysis employed the following configuration:
- HPLC column: Shim-pack Scepter C18, 100 mm×2.1 mm I.D., 1.9 µm
- Mobile phase: methanol
- Flow rate: 0.4 mL/min; injection volume: 1 µL
- Detection: photodiode array (PDA) at 210–500 nm
- Mass spectrometer: LCMS-2050 single quadrupole
- Ionization: DUIS mode enabling concurrent ESI and APCI
- Scan range: m/z 250–800 in positive and negative modes
- Interface voltages: +3.0 kV (ESI), +3.0 kV corona needle (APCI); DL/QA voltages ±20 V
- Gas flows: nebulizing 2.0 L/min, drying 5.0 L/min, heating 7.0 L/min; DL temperature 200 °C
Seven representative OLED analytes were prepared at 0.1 mg/mL in THF/methanol: coronene, TAPC, CBP, DPEPO, rubrene, TCTA, and 9,10-diphenylanthracene.
Main Results and Discussion
Mass spectra of the principal PDA peaks confirmed monoisotopic masses consistent with the target compounds (e.g., coronene m/z 300.0939 [M+H]+, TAPC m/z 626.3661). The DUIS source effectively ionized both polar and low-polarity species, eliminating the need for separate analyses. Impurity profiling in TAPC revealed ultra-trace byproducts, with retention times and m/z values catalogued for nine impurity peaks. Combined PDA and MS chromatograms facilitated reliable peak assignment and impurity identification.
Benefits and Practical Application
The integrated single quadrupole LC/MS approach offers:
- Rapid confirmation of target molecular weights without high-resolution MS
- Simultaneous detection of a broad polarity range through DUIS
- Efficient impurity screening for quality control in OLED synthesis
These capabilities support routine testing in research, manufacturing QA/QC, and regulatory compliance.
Future Trends and Applications
Advancements may include coupling DUIS-enabled quadrupole systems with high-throughput HPLC for inline process monitoring. Expansion to other low-polarity organic materials and integration with data-driven predictive models will further enhance real-time decision making in material development. Potential improvements in source design and software algorithms could enable semi-quantitative impurity profiling and automated reporting.
Conclusion
The study validates the LCMS-2050 single quadrupole with DUIS as a robust platform for comprehensive analysis of OLED materials and impurities. It delivers accurate mass confirmation, broad ionization coverage, and streamlined workflows, making it a valuable tool for both research and industrial quality assurance.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Organic EL Materials and Impurities Using Single Quadrupole Mass Spectrometer
2022|Shimadzu|Applications
LCMS-2050 High Performance Liquid Chromatograph Mass Spectrometer Application News Analysis of Organic EL Materials and Impurities Using Single Quadrupole Mass Spectrometer M. Kawashima, Y. Inohana User Benefits The synthesis of organic EL materials can be easily confirmed using a…
Key words
organic, organictapc, tapcimpurities, impuritiesmaterials, materialsdpepo, dpepotcta, tctasynthesis, synthesisphosphorescent, phosphorescentrubrene, rubrenecbp, cbpabsorb, absorbquadrupole, quadrupolecheck, checklight, lightspectrometer
Confirmation of Synthesis of Organic EL Materials Using Direct Infusion Mass Spectrometry
2023|Shimadzu|Applications
High Performance Liquid Chromatograph Mass Spectrometer LCMS-2050 Confirmation of Synthesis of Organic EL Materials Using Direct Infusion Mass Spectrometry Application News Takanari Hattori and Yasuko Shibayama User Benefits By injecting a sample using direct infusion into a single quadrupole…
Key words
infusion, infusiondirect, directnews, newsmass, massmolecular, molecularconfirmed, confirmedsynthesis, synthesisweight, weightapplication, applicationshibayama, shibayamayasuko, yasukohattori, hattoritakanari, takanarisingle, singletof
Shimadzu LCMS-2020
2021|Shimadzu|Brochures and specifications
C146-E121G Liquid Chromatograph Mass Spectrometer LCMS-2020 LCMS-2020 —Seeing is Believing. Ultra Fast UFswitching™ Rapid 15 msec Polarity Switching Ultra Fast UFsensitivity™ Superior Sensitivity with UHPLC Ultra Fast UFscanning™ 15,000 u/sec Fast Scanning Speed Speed is Power. Greater speed. Greater sensitivity.…
Key words
ufscanning, ufscanningultra, ultraufswitching, ufswitchingerythromycin, erythromycinpositive, positivedymuron, dymuronfast, fastcid, cidbrowser, browserswitching, switchingpurification, purificationnegative, negativeion, iondisplays, displaysdata
Technical Background for the LCMS-2050, a Compact Mass Detector for LC
2022|Shimadzu|Technical notes
C146-E453 Technical Report Technical Background for the LCMS-2050, a Compact Mass Detector for LC Katsuaki Koterasawa1, Kazuo Mukaibatake1, Atsuhiko Toyama1 A b s tra c t: The LCMS-2050 single quadrupole mass spectrometer is highly compact in size, yet provides both…
Key words
esi, esiionization, ionizationuptake, uptakeionizer, ionizermass, masspropranolol, propranololcorona, coronarods, rodsport, portion, ionapplied, appliedvacuum, vacuumcycle, cyclevoltage, voltageseparator