Separation of Water-Soluble Vitamins on the Agilent InfinityLab Poroshell 120 Aq-C18 Column

Applications | 2022 | Agilent TechnologiesInstrumentation
Consumables, HPLC, LC columns
Industries
Food & Agriculture, Pharma & Biopharma
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Water-soluble vitamins play essential roles in health and nutrition. Their high polarity challenges conventional reversed-phase separations, demanding advanced stationary phases capable of retaining and resolving these analytes.

Objectives and Study Overview


This application note evaluates the performance of the Agilent InfinityLab Poroshell 120 Aq-C18 column for simultaneous separation of ten B vitamins, ascorbic acid, and caffeine. The goals include achieving baseline separation, symmetrical peak shapes, and robust reproducibility under highly aqueous conditions.

Methodology and Instrumentation


An Agilent 1290 Infinity LC system with a binary pump, autosampler, column compartment, and diode array detector was employed. Key parameters included:
  • Column: Poroshell 120 Aq-C18, 4.6 × 100 mm, 2.7 µm
  • Mobile phase A: 10 mM phosphate buffer, pH 2.5; B: acetonitrile
  • Gradient: 0–2 min, 0–6% B; 2–6 min, 6–25% B; 6–8 min, 25–70% B; hold to 10 min
  • Flow rate: 1.5 mL/min; temperature: 30 °C; detection at 210 and 260 nm

Main Results and Discussion


Baseline separation of 12 compounds was achieved with symmetrical peaks. Highly polar analytes, including thiamine and ascorbic acid, showed strong retention under 100% aqueous start conditions. Pantothenic acid and biotin, undetectable at 260 nm, were monitored at 210 nm. Reproducibility testing with six consecutive injections demonstrated minimal variation in retention time and peak area, highlighting column stability and resistance to dewetting in polar mobile phases.

Benefits and Practical Applications


  • Enhanced retention and resolution of polar nutrients in a single run
  • Reduced analysis time and improved peak shapes for routine QC
  • Compatibility with highly aqueous mobile phases without dewetting

Future Trends and Opportunities


Continued development of superficially porous phases may extend analysis to highly polar biomolecules and complex vitamin matrices. Coupling with mass spectrometry and automated sample preparation could streamline workflows in pharmaceutical, food, and clinical laboratories.

Conclusion


The Agilent InfinityLab Poroshell 120 Aq-C18 column delivers reliable, high-resolution separations of water-soluble vitamins and caffeine under highly aqueous gradients, with excellent reproducibility and peak performance.

Reference


Fu RJ, Wei TC. Analysis of Polar Compounds Using an Agilent InfinityLab Poroshell 120 Aq-C18 Column with Improved and Reliable Performance. Agilent Technologies application note 5994-5555EN. 2022.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Fat- and Water-Soluble Vitamin Analysis in Foods and Supplements (Consumable Workflow Ordering Guide)
Consumable Workflow Ordering Guide Fat- and Water-Soluble Vitamin Analysis in Foods and Supplements The body requires 13 vitamins to function properly: A, C, D, E, K, and the B vitamins (thiamine, riboflavin, niacin, pantothenic acid, biotin, vitamin B-6, vitamin B-12,…
Key words
vitamins, vitaminssoluble, solubledad, dadfat, fatinfinitylab, infinitylabvitamin, vitaminsupplies, supplieshplc, hplcmin, minultrapure, ultrapurestay, staywater, wateragilent, agilentsafe, safetime
Accelerated method development for the separation of water-soluble vitamins by RP-HPLC with UV detection using an empirical approach to predict separation
APPLICATION NOTE 72877 Accelerated method development for the separation of water-soluble vitamins by RP-HPLC with UV detection using an empirical approach to predict separation Authors Sylvia Grosse, Soo Hyun Park, Mauro De Pra, Frank Steiner Thermo Fisher Scientific, Germering, Germany…
Key words
acid, acidpolar, polarpantothenic, pantothenicwsvs, wsvspredicted, predictedbiotin, biotinscientific, scientificfolic, folicriboflavin, riboflavinmethod, methodpyridoxal, pyridoxalvanquish, vanquishcyanocobalamin, cyanocobalaminchromsword, chromswordthiamine
Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC
APPLICATION NOTE 72592 Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC Authors Sylvia Grosse, Mauro De Pra, Frank Steiner Thermo Fisher Scientific, Germering, Germany Application…
Key words
tocopherole, tocopherolevitamin, vitaminretinol, retinoltablet, tabletvitamins, vitaminsfsv, fsvwsv, wsvphyllochinone, phyllochinonethiamine, thiaminesoluble, solublemenaquinone, menaquinoneacid, acidpyridoxin, pyridoxincyanocobalamin, cyanocobalaminacetate
Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC
APPLICATION NOTE 72592 Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC Authors Sylvia Grosse, Mauro De Pra, Frank Steiner Thermo Fisher Scientific, Germering, Germany Application…
Key words
tocopherole, tocopherolevitamin, vitaminretinol, retinoltablet, tabletvitamins, vitaminsfsv, fsvwsv, wsvphyllochinone, phyllochinonethiamine, thiaminesoluble, solublemenaquinone, menaquinonepyridoxin, pyridoxinacid, acidacetate, acetatecyanocobalamin
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike