Master Your Polar Molecules, Especially Under Water
Others | 2022 | Agilent TechnologiesInstrumentation
The analysis of highly polar compounds by reversed-phase liquid chromatography often suffers from poor retention when using conventional C18 phases and high organic content. Achieving reliable separation with 100% aqueous mobile phases is crucial for pharmaceuticals, food analysis, environmental monitoring, and biochemical studies where polar analytes coexist with nonpolar species.
This overview evaluates the performance of Agilent InfinityLab Poroshell 120 Aq-C18 columns, designed to maintain phase stability in fully aqueous conditions, and examines their ability to retain and resolve both polar and nonpolar analytes under HPLC and UHPLC pressures.
Chromatographic protocols were optimized for two test mixtures:
Key parameters included flow rates from 1 to 1.5 mL/min, column temperatures at 30 °C, and injection volumes of 1–2 µL.
Further advances in superficially porous stationary phases and column hardware will likely extend capabilities to even more polar and labile analytes. Integration with mass spectrometry, miniaturized formats, and green mobile-phase strategies will broaden application scope in high-throughput screening and targeted metabolomics.
Agilent InfinityLab Poroshell 120 Aq-C18 columns provide a versatile solution for reversed-phase separations of polar and nonpolar compounds under fully aqueous conditions. Their superior retention, resolution, reproducibility, and scalability address longstanding challenges in modern analytical workflows.
Consumables, LC columns
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
The analysis of highly polar compounds by reversed-phase liquid chromatography often suffers from poor retention when using conventional C18 phases and high organic content. Achieving reliable separation with 100% aqueous mobile phases is crucial for pharmaceuticals, food analysis, environmental monitoring, and biochemical studies where polar analytes coexist with nonpolar species.
Study Objectives and Overview
This overview evaluates the performance of Agilent InfinityLab Poroshell 120 Aq-C18 columns, designed to maintain phase stability in fully aqueous conditions, and examines their ability to retain and resolve both polar and nonpolar analytes under HPLC and UHPLC pressures.
Methodology
Chromatographic protocols were optimized for two test mixtures:
- Water-soluble vitamins using a gradient from 100% aqueous phosphate buffer (pH 2.5) to acetonitrile.
- Nine organic acids under isocratic conditions with 97.5% aqueous phosphoric acid and 2.5% methanol.
Key parameters included flow rates from 1 to 1.5 mL/min, column temperatures at 30 °C, and injection volumes of 1–2 µL.
Instrumentation Used
- Agilent 1290 Infinity II Binary Pump
- Agilent InfinityLab Poroshell 120 Aq-C18 columns, 2.7 µm superficially porous particles
- UV detector recording at 210 nm and 260 nm
Main Results and Discussion
- Vitamins Separation: Twelve water-soluble vitamins exhibited baseline resolution in a single run, with early-eluting polar compounds retained effectively despite 100% aqueous start conditions.
- Organic Acids Comparison: All nine acids showed stronger retention, sharper peaks, and improved resolution compared to competitor columns of similar dimensions and particle sizes.
- Reproducibility and Scalability: Batch-to-batch consistency was confirmed, and performance was maintained across both HPLC and UHPLC systems, facilitating direct method transfer.
Benefits and Practical Applications
- Enhanced retention of challenging polar analytes without phase collapse or dewetting.
- Smooth method transfer between analytical LC and UHPLC platforms due to lower backpressure and robust superficially porous technology.
- Applicability across diverse fields such as pharmaceutical impurity profiling, metabolomics, food quality control, and environmental screening.
Future Trends and Opportunities
Further advances in superficially porous stationary phases and column hardware will likely extend capabilities to even more polar and labile analytes. Integration with mass spectrometry, miniaturized formats, and green mobile-phase strategies will broaden application scope in high-throughput screening and targeted metabolomics.
Conclusion
Agilent InfinityLab Poroshell 120 Aq-C18 columns provide a versatile solution for reversed-phase separations of polar and nonpolar compounds under fully aqueous conditions. Their superior retention, resolution, reproducibility, and scalability address longstanding challenges in modern analytical workflows.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Updating Old Methods:Is the Gain Worth the Pain? - Becoming a Better Chromatographer HPLC educational webinar
2019|Agilent Technologies|Presentations
Updating Old Methods: Is the Gain Worth the Pain? Becoming a Better Chromatographer HPLC educational webinar Mark Powell Applications Engineer Columns and Supplies Technical Support Why Would You Consider Updating? What Is the Goal? • Do I need to update?…
Key words
mau, mauchiral, chiralmin, mininfinitylab, infinitylabporoshell, poroshellparticle, particlecolumn, columnagilent, agilentdeemter, deemterallowed, alloweddiffusion, diffusionvan, vanphase, phasechanges, changesmobile
Perform Rugged, Fast LC with Confidence - Agilent InfinityLab Poroshell 120 columns for HPLC and UHPLC
2020|Agilent Technologies|Brochures and specifications
Perform Rugged, Fast LC with Confidence Agilent InfinityLab Poroshell 120 columns for HPLC and UHPLC 2 A Tradition of Innovation and Efficiency More than 15 years ago, Agilent introduced the industry's first superficially porous column technology with Poroshell 300 for…
Key words
mau, mauchiral, chiralmin, minhilic, hilicinfinitylab, infinitylabproprietary, proprietarybest, bestsize, sizepfp, pfppolar, polarhexyl, hexylphenyl, phenylyour, yourporoshell, poroshellbonus
The LC Column Playbook
2017|Agilent Technologies|Presentations
The LC Column Playbook Mark Powell Applications Engineer Technical Support October 10, 2017 1 October 10, 2017 Overview How do we achieve our goal: Resolution? • Efficiency • Particle size • Column length • Selectivity • Bonded phase • Mobile…
Key words
hilic, hilicporoshell, poroshellmau, maupolar, polarselectivity, selectivitybest, bestphases, phasesresolution, resolutionphase, phasemin, minparticle, particleⅆ𝑝, ⅆ𝑝mobile, mobilebonded, bondedconfidentiality
WhereDo I Go from Here: Updating Old HPLC Methods
2021|Agilent Technologies|Presentations
Where Do I Go from Here: Updating Old HPLC Methods Rita Steed Columns and Supplies Technical Support February 17, 2021 Is Now the Time to Update a Method? • Improved technology available − E.g., Poroshell 120 − UHPLC • Save…
Key words
updating, updatingold, oldhplc, hplczorbax, zorbaxmethods, methodsmau, maucolumn, columnmin, minvolume, volumegradient, gradientchemistries, chemistrieseclipse, eclipseporoshell, poroshellaligned, alignedparticle