LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Clarity Lite v.2.2 (Clarity Lite vs CSW32)

Manuals | 2005 | DataApexInstrumentation
Software
Industries
Manufacturer
DataApex

Summary

Importance of the Topic


The evolution of chromatographic data systems toward multidetector support meets the growing demand for higher throughput and richer analytical information. Clarity Lite version 2.2 introduces a unified environment for managing up to four detector signals simultaneously, ensuring consistent traceability and streamlined workflows in quality control, research laboratories, and industrial analytics.

Study Objectives and Overview


This document compares Clarity Lite with its predecessor CSW32. The primary goals are to:
  • Outline enhancements in multidetector data acquisition and processing
  • Describe new table layouts and integration controls
  • Review calibration management and reporting improvements
  • Highlight compatibility with legacy file formats

Methodology and Instrumentation


Clarity Lite’s architecture centers on Plug and Play A/D converters (INT7 and U-PAD). Key procedural elements include:
  • Single chromatogram files storing multiple detector signals
  • Method templates split into Measurement Conditions, Acquisition, Integration, and Calculations
  • Integrated calibration files containing signal-specific curves for each detector
  • Automated configuration of up to four instruments within one station

Main Results and Discussion


Major advances over CSW32 include:
  • Multiple Detector Arrangement: Simultaneous capture, display, and evaluation of up to four detectors in one chromatogram window
  • Summary Results Table: Consolidated, invertible rows/columns view of all calibrated peaks, easily exported in tab‐delimited text
  • Enhanced Integration Control: Interval-based parameters, interactive line tools, repeatable commands for precise baseline and peak adjustment
  • Flexible Scaling and Visualization: Individual or combined autoscaling, user-defined signal colors, mouse-wheel zoom and pan
  • Improved Calibration Handling: Signal-specific response factors, sigmoid interpolation, detailed recalibration counters, and per-compound unit display
  • Streamlined Sequence Management: Inline insertion and drag-drop reordering, snapshot function, and direct run control from the acquisition window
  • Advanced Reporting and Printing: Conditional printing of valid levels, active-signal selection, automatic style saving, and full HTML export capability

Benefits and Practical Applications


Clarity Lite’s integrated multidetector approach reduces file proliferation and manual synchronization. Laboratories benefit from:
  • Faster method deployment via unified templates and one-click calibration file creation
  • Full traceability through embedded method histories and stored calibration curves
  • Higher data integrity with audit-compatible chromatogram histories
  • Customizable reports and easy export for LIMS or peer review

Future Trends and Opportunities


As automation and high-resolution detectors evolve, future enhancements may include cloud-based data sharing, AI-driven peak detection, support for real-time method optimization, and extended control of chromatographic hardware. Integration with laboratory information systems and advanced security layers is expected to enhance compliance and remote operation.

Conclusion


Clarity Lite v.2.2 represents a significant step beyond CSW32 by consolidating multidetector data acquisition, enriching integration controls, and simplifying calibration and reporting. Its balance of advanced features and backward compatibility ensures that both legacy and modern workflows are fully supported.

Reference


DataApex Ltd. Clarity Lite vs CSW32, Rev. B, 06 April 2005.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity (Lite) 2.4 vs 2.3
Clarity (Lite) 2.4 vs 2.3
2007|DataApex|Manuals
Clarity (Lite) Clarity 2.4(Lite) vs 2.3 2.4 vs 2.3 ENG Code/Rev.: M047/24F – 02 January 2006 Phone: +420 - 251 013 400 Fax: +420 - 251 013 401 [email protected] www.dataapex.com © DataApex Ltd. 2007 Podohradská 1 155 00 Prague 5…
Key words
clarity, claritychromatogram, chromatogramcommand, commandthreshold, thresholdfile, fileopen, opendialog, dialoginstrument, instrumentfft, fftset, setsend, sendinterval, intervalwindow, windowpdf, pdfgpc
Clarity Lite Software GETTING STARTED
GETTING STARTED Clarity Lite Software ENG Code/Rev.: M012/80K Date: 10/25/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
getting, gettingstarted, startedlite, liteclarity, claritysequence, sequencefile, filewindow, windowchromatogram, chromatogramicon, iconyou, youstart, startchromatograph, chromatographopen, opencalibration, calibrationerror
Clarity Software REFERENCE GUIDE
REFERENCE GUIDE Clarity Software ENG Code/Rev.: M018/80Y Date: 1/17/2023 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic Sections of the manual connected only to the Clarity Full version are marked…
Key words
guide, guidedialog, dialogchromatogram, chromatogramreference, referencecommand, commandfile, filewindow, windowcalibration, calibrationtable, tabletab, tabsequence, sequenceclarity, clarityuser, userall, alldisplays
Clarity Demo Software
Clarity Demo Software
2021|DataApex|Manuals
CLARITY DEMO Clarity Demo Software ENG Code/Rev.: M003/80G Date: 2/10/2021 Phone: +420 251 013 400 Fax: +420 251 013 401 [email protected] www.dataapex.com DataApex Ltd. Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft…
Key words
clarity, claritydemo, demowindow, windowchromatogram, chromatogramicon, iconmodule, moduleopen, openstation, stationyou, youintegrated, integratedcan, canname, nameevaluating, evaluatingsequence, sequenceclicking
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike