Know the «True» Sodium Content
Applications | 2010 | MetrohmInstrumentation
Accurate determination of sodium in food products is essential for consumer health, regulatory compliance and quality control. Conventional indirect analyses based on chloride measurements often misestimate true sodium levels when additional sodium or chloride sources are present. A direct, rapid and cost-effective approach helps food laboratories deliver reliable sodium data without extensive sample preparation or high instrument costs.
The primary goal of this work is to introduce and validate a direct thermometric titration method for sodium analysis that overcomes the limitations of traditional indirect chloride titrations and high-cost spectroscopic techniques. The study compares results obtained by thermometric titration with those from inductively coupled plasma (ICP) analysis across a range of common food matrices.
Thermometric titration uses the heat change associated with a chemical reaction to detect the endpoint. In this application, sodium in homogenized food samples reacts with a standardized aluminum-fluoride titrant at acidic pH to form insoluble NaK2AlF6. The preparation involves mastication and homogenization of samples, followed by titration with an excess of Al3+ and K+ in the presence of fluoride. Calibration of the titrant is performed against an anhydrous sodium sulfate standard.
Thermometric titration results closely match sodium contents measured by ICP across diverse food types. Relative standard deviations (RSDs) were consistently low (0.5–1.1 %), indicating high precision. Average sodium percentages determined by each method were:
The method demonstrated robustness against matrix interferences, rapid sample throughput and minimal reagent consumption compared to spectroscopic techniques.
Thermometric titration can be integrated into automated workflows and online process monitoring for continuous quality control. Adaptations to emerging food ingredients and complex formulations will expand its utility. Development of greener fluoride sources and miniaturized titration modules may further reduce environmental impact and operational costs.
Direct thermometric titration offers a reliable, precise and economical alternative for sodium analysis in food products. Its strong agreement with ICP data, rapid throughput and low operational complexity make it an attractive choice for laboratories focused on accurate sodium quantification.
No external literature references were provided in the original text.
Titration
IndustriesFood & Agriculture
ManufacturerMetrohm
Summary
Analysis of Sodium in Foodstuffs by Thermometric Titration
Significance of the Topic
Accurate determination of sodium in food products is essential for consumer health, regulatory compliance and quality control. Conventional indirect analyses based on chloride measurements often misestimate true sodium levels when additional sodium or chloride sources are present. A direct, rapid and cost-effective approach helps food laboratories deliver reliable sodium data without extensive sample preparation or high instrument costs.
Objectives and Study Overview
The primary goal of this work is to introduce and validate a direct thermometric titration method for sodium analysis that overcomes the limitations of traditional indirect chloride titrations and high-cost spectroscopic techniques. The study compares results obtained by thermometric titration with those from inductively coupled plasma (ICP) analysis across a range of common food matrices.
Methodology
Thermometric titration uses the heat change associated with a chemical reaction to detect the endpoint. In this application, sodium in homogenized food samples reacts with a standardized aluminum-fluoride titrant at acidic pH to form insoluble NaK2AlF6. The preparation involves mastication and homogenization of samples, followed by titration with an excess of Al3+ and K+ in the presence of fluoride. Calibration of the titrant is performed against an anhydrous sodium sulfate standard.
Used Instrumentation
- 859 Titrotherm thermometric titrator
- Titrant: 0.5 mol/L Al(NO3)3 and 0.5 mol/L KNO3
- Complexation reagent: 300 g/L NH4F·HF
- Waste neutralization: saturated boric acid solution
Main Results and Discussion
Thermometric titration results closely match sodium contents measured by ICP across diverse food types. Relative standard deviations (RSDs) were consistently low (0.5–1.1 %), indicating high precision. Average sodium percentages determined by each method were:
- Ketchup: 1.3 % (ICP), 1.3 % (titration), RSD 0.008
- Yellow mustard: 0.9 % (ICP), 1.2 % (titration), RSD 0.005
- Green beans: 0.2 % (ICP), 0.3 % (titration), RSD 0.011
- Seasoned potato chips: 0.4 % (ICP), 0.6 % (titration), RSD 0.113
- Mini pretzels: 1.1 % (ICP), 1.0 % (titration), RSD 0.078
The method demonstrated robustness against matrix interferences, rapid sample throughput and minimal reagent consumption compared to spectroscopic techniques.
Practical Benefits and Applications
- Direct sodium measurement eliminates errors from chloride-based assumptions.
- Lower capital investment and no need for ultra-pure reagents.
- Reduced sample preparation time enhances laboratory productivity.
- Applicable to a wide range of food matrices in QA/QC and research settings.
Future Trends and Potential Applications
Thermometric titration can be integrated into automated workflows and online process monitoring for continuous quality control. Adaptations to emerging food ingredients and complex formulations will expand its utility. Development of greener fluoride sources and miniaturized titration modules may further reduce environmental impact and operational costs.
Conclusion
Direct thermometric titration offers a reliable, precise and economical alternative for sodium analysis in food products. Its strong agreement with ICP data, rapid throughput and low operational complexity make it an attractive choice for laboratories focused on accurate sodium quantification.
References
No external literature references were provided in the original text.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Fully automatic determination of sodium in food samples – Know the “true” sodium content
|Metrohm|Posters
Fully automatic determination of sodium in food samples – Know the “true” sodium content T. Smith1, C. Thielen2, I. Kalkman2, B. Dehédin2, and C. Haider2 Instrumentation Sodium is one of the most common inorganic cations in food that is mostly…
Key words
titration, titrationsodium, sodiumthermometric, thermometricfoodstuffs, foodstuffsfood, fooddetermined, determinedsubtracts, subtractsketchup, ketchupinflection, inflectiontiamo, tiamotitrating, titratingindirectly, indirectlyblank, blankcontent, contentchange
859 Titrotherm
2012|Metrohm|Brochures and specifications
859 Titrotherm Thermometric titration – the ideal complement to potentiometric titration What is thermometric titration? 02 Titration is the oldest and most widespread method used in analytical chemistry. For a long time now, potentiometric sensors (indicator electrodes) have been used…
Key words
titration, titrationthermometric, thermometricpotentiometric, potentiometricthermoprobe, thermoprobechange, changesensor, sensorelectrode, electrodeacid, acidtitrotherm, titrothermreaction, reactiontiamotm, tiamotmfree, freesodium, sodiumsuitable, suitabletitrated
Automated determination of sodium in milk with 859 Titrotherm and 814 USB Sample Processor
|Metrohm|Applications
Application Bulletin 343/1e Automated determination of sodium in milk with 859 Titrotherm and 814 USB Sample Processor Page 1/6 Automated determination of sodium in milk with 859 Titrotherm and 814 USB Sample Processor Of interest to: Food (dairy) industry Summary…
Key words
milk, milktitrant, titrantmolarity, molaritytitration, titrationblank, blankintercept, interceptslope, slopeskim, skimsodium, sodiumdetermination, determinationcream, creamcalcium, calciumcalculations, calculationsdip, dipautomated
Automated sodium determination in various foods with 859 Titrotherm
2012|Metrohm|Applications
Application Bulletin 298 e Automated sodium determination in various foods with 859 Titrotherm Automated sodium determination in various foods with 859 Titrotherm Keywords TITER DETERMINATION total sodium / bouillon / gravy / tomato ketchup / corn chips / pretzel sticks…
Key words
bouillon, bouillonpretzel, pretzelgravy, gravyketchup, ketchupsticks, stickscalculation, calculationchips, chipsdetermination, determinationcorn, cornpolytron, polytrondeviation, deviationtiter, titercracker, crackercrackers, crackersintercept