LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Recommendations for titration methods validation

Technical notes | 2021 | MetrohmInstrumentation
Titration, Titration Karl Fischer
Industries
Manufacturer
Metrohm

Summary

Significance of the Topic


Volumetric titration remains a cornerstone technique for quantitative analysis in pharmaceutical, environmental and industrial laboratories.

Accurate method validation ensures compliance with regulatory requirements (ICH, USP) and delivers reliable results crucial for quality control and decision making.

Objectives and Study Overview


This white paper outlines best practices for validating acid–base titration procedures.

It aligns with ICH Q2(R1) and USP <1225> guidance and illustrates key validation parameters using the titration of potassium bicarbonate as a case study.

Methodology and Instrumentation


Key steps in method validation:
  • Titrant standardization at the same temperature as the sample titration, using primary standards to correct nominal concentration and account for volume expansion.
  • Specificity testing by spiking the analyte with potential interferents (e.g., potassium carbonate) and observing equivalence points via potentiometric sensors or alternative indicators.
  • Linearity assessment across at least five concentrations (50–150 % of assay weight) and calculation of the determination coefficient (R²).
  • Accuracy and precision evaluation using nine independent determinations at 80 %, 100 % and 120 % of the nominal weight, reporting mean recovery, standard deviation and relative standard deviation.

Instrumentation:
  • Automated potentiometric titrator with appropriate pH or ion-selective electrodes.
  • Manual titration setup with standardized burettes and color indicators as needed.

Main Results and Discussion


Specificity test of 1 g KHCO₃ spiked with 0.5 g K₂CO₃ produced two distinct equivalence points, demonstrating clear separation of analyte and impurity.

Linearity data over 50–150 % sample size yielded R² = 0.9999, confirming direct proportionality between sample mass and titrant volume.

Accuracy and repeatability studies (nine replicates) achieved a mean assay of 100.40 % and RSD = 0.43 %, matching certificate of analysis (99.9 %).

Intermediate precision on a separate day returned a mean of 100.46 % and RSD = 0.43 %, satisfying intra-laboratory precision criteria.

Benefits and Practical Applications


Validated titration protocols deliver robust, reproducible quantification of active substances and impurities.

They support routine quality control, stability testing and regulatory filings in pharmaceutical and chemical industries.

Future Trends and Potential Applications


Emerging developments include integration of advanced sensors, inline monitoring and chemometric data processing to enhance sensitivity and throughput.

Applications may extend to complex matrices, multi-endpoint titrations and automated high-throughput platforms.

Conclusion


A comprehensive validation strategy—encompassing titrant standardization, specificity, linearity, accuracy and precision—is essential to ensure the reliability of titration methods.

When specificity cannot be fully achieved by titration alone, orthogonal analytical techniques should be applied.

References


  • ICH Guidance Q2(R1) Validation of Analytical Procedures: Text and Methodology, ICH, 2005.
  • USP <1225> Validation of Compendial Procedures. USP 43–NF 38, 2020.
  • USP Volumetric Solutions. USP 43–NF 38, First Supplement, 2020.
  • USP Potassium Bicarbonate. USP 43–NF 38, First Supplement, 2020.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Assay of potassium carbonate and potassium bicarbonate
www.metrohm.com The front picture is placed in a text box with a size of 21 cm width and 14 cm height. To insert a photo click in the upper right corner and insert a picture. Assay of potassium carbonate and…
Key words
potassium, potassiumbicarbonate, bicarbonatecarbonate, carbonatetitration, titrationinflection, inflectionequivalence, equivalenceassay, assayomnis, omnispotentiometric, potentiometricnine, ninesecond, secondmanufacturer, manufactureraccuracy, accuracyspecificity, specificitycoa
USP Monograph Modernization Initiative: Chemical Medicines Assay by Potentiometric Titration
T1030-07-0558 USP Monograph Modernization Initiative: Chemical Medicines Assay by Potentiometric Titration 1 Narayanan , 1 Koch , 2 Meier , Hari Frank Lucia 1 2 3 Metrohm USA Inc , Metrohm AG , USP Michael 3 Chang , Leonel M…
Key words
inflection, inflectionpass, passassay, assaypotassium, potassiumautotitration, autotitrationtitration, titrationcarbonate, carbonateequivalence, equivalencesecond, secondbicarbonate, bicarbonatemanufacturer, manufacturerpoint, pointcoa, coausp, usppotentiometric
Recommendations for converting a manual titration procedure into an automated titration procedure
WHITE PAPER Recommendations for converting a manual titration procedure into an automated titration procedure While several titration methods for assays in compendial monographs are being converted to chromatographic methods or other quantitative procedures, titration still plays an important role in…
Key words
titration, titrationelectrode, electrodecombined, combinedtitrations, titrationsendpoint, endpointaqueous, aqueoustitrant, titrantautomated, automatedmonotonic, monotonicmanual, manualpotassium, potassiumplatinum, platinumsuitable, suitablesilver, silvernon
Determination of the total base number in petroleum products
Application Bulletin 405/2 e Determination of the total base number in petroleum products Branch General analytical chemistry; petrochemical industry Potentiometric determination Instruments Keywords Titration; non aqueous titration; potentiometric titration; photometric titration; thermometric titration; Solvotrode easyClean; Optrode; Thermoprobe; Conductivity measuring cell;…
Key words
tbn, tbntiter, titertitrant, titranttitration, titrationbase, basedetermination, determinationsample, samplepetroleum, petroleumnumber, numberthermometric, thermometricmol, molcriterion, criterionkoh, kohblank, blankconsumption
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike