917 Coulometer
Manuals | 2022 | MetrohmInstrumentationImportance of Coulometric Titration in Analytical Chemistry
Objectives and System Overview
Methodology and Instrumentation
Main Features and Discussion of Key Functions
Benefits and Practical Applications
Future Trends and Potential Applications
Conclusion
Voltammetry/Coulometry
IndustriesManufacturerMetrohm
Summary
Importance of Coulometric Titration in Analytical Chemistry
Coulometric titration methods, particularly Karl Fischer (KFC) water content and bromine index (BRC) determinations, are essential tools for trace water and unsaturation analysis in pharmaceuticals, food, petrochemicals and environmental samples. The 917 Coulometer integrates precise current‐controlled reagent generation, automated dosing, stirring and data management into one compact titrator. Its combination of onboard touchscreen, Ethernet networking, USB connectivity and full GLP/GMP support streamlines routine and high‐precision analyses.
Objectives and System Overview
- Describe the design, installation and safe operation of the Metrohm 917 Coulometer.
- Detail methods for KFC water titration, bromine index measurement, manual operation and automation functions.
- Explain data handling, method development, user access controls, audit trails and GLP/GMP compliance features.
Methodology and Instrumentation
- Instrument: 917 Coulometer (Metrohm) with integrated magnetic stirrer, membrane pump and touchscreen.
- Reagents: Coulometric reagents for KFC and BRC methods, monitored for capacity, drift and usage.
- Electrodes: Generator and indicator Pt electrodes, optional diaphragm cells, temperature sensor (Pt1000 or NTC).
- Automation: MSB bus for Dosino/Dosimat dosing devices, additional stirrers, Remote Box; USB for printers, balance, keyboard, barcode reader; Ethernet for PC/LIMS and file sharing.
- Software: Version 5.917.0025 with method editor, command language (SCAN, CTRL, CALC, REPORT), comprehensive user administration and audit trail, electronic signatures (21 CFR Part 11), GLP manager and system validation.
Main Features and Discussion of Key Functions
- Method Editor: Graphical sequence editor with >100 commands, parameter groups for titration, measurement, dosing, automation and reporting. Routine/expert modes customize user interface.
- Data Management: Internal and external memory file management, backup/restore, shared network directories, USB storage. PC/LIMS report generation in ISO 8859-1 or UTF-8.
- Operation: Live display with curve and measured values, manual control of dosing, stirring, temperature, gas flow; automated titration cell conditioning; sample table and series statistics (mean, SD).
- Reporting: Custom report headers, PDF/print output, system/method/protocol reports, result tables, measuring point lists, GLP reports, device and variable lists.
- Quality Assurance: User roles, password policies, electronic signatures with two‐level review and release, audit trail for security, data changes and system events.
Benefits and Practical Applications
- High precision and absolute titration (no titer) via coulometric reagent generation; ideal for low‐level water and bromine index analysis.
- Compact footprint with integrated pump and stirrer, suitable for small lab spaces or fume hood operation.
- Seamless integration into lab networks and LIMS, with data sharing, centralized method distribution and report archiving.
- Automated and manual workflows support R&D, QA/QC and production environments, including sample racks and ovens (885 Compact Oven SC).
- Full 21 CFR Part 11 and GLP/GMP compliance with method validation, system tests, electronic records and signatures, audit trails and user privileges.
Future Trends and Potential Applications
- Integration with more advanced robotic sample processors and high-throughput screening in process analytical technology (PAT) environments.
- Enhanced connectivity with IoT platforms for remote monitoring, predictive maintenance and cloud‐based data analytics.
- Implementation of machine‐learning algorithms for endpoint detection and dynamic titration control.
- Expansion of method libraries with additional coulometric applications and multi‐parameter titrations.
Conclusion
The Metrohm 917 Coulometer combines robust hardware, flexible software and stringent quality systems to deliver accurate and traceable coulometric titrations. Its modular design, comprehensive data management and full regulatory support make it a versatile solution for water content, bromine index and other coulometric analyses across diverse industries. Continuous advancement in automation and digital integration will further enhance its capabilities for modern analytical laboratories.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
916 Ti‑Touch - Manual
2022|Metrohm|Manuals
916 Ti‑Touch Manual 8.916.8005EN / 2022-04-30 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com 916 Ti‑Touch Program version 5.916.0045 Manual 8.916.8005EN / 2022-04-30 Technical Communication Metrohm AG CH-9100 Herisau This documentation is protected by copyright. All…
Key words
default, defaultvalue, valueinput, inputselection, selectiondosing, dosingoff, offrange, rangenotice, noticedialog, dialogtitration, titrationmaximum, maximumentry, entrymessage, messagecommand, commanddetermination
917 Coulometer
2019|Metrohm|Manuals
917 Coulometer Tutorial 8.917.8001EN Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 917 Coulometer Tutorial 8.917.8001EN 01.2019 Technical Communication Metrohm AG CH-9100 Herisau [email protected] This documentation is protected by…
Key words
notice, noticetitration, titrationelectrode, electrodedialog, dialogaspiration, aspirationconnecting, connectinglogin, loginusb, usbcell, cellsymbol, symbolcable, cablebottle, bottlereagent, reagenttap, tapswitch
Eco Titrator
2021|Metrohm|Manuals
Eco Titrator Product manual 8.1008.8001EN / 2021-08-27 Metrohm AG Ionenstrasse CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com Eco Titrator Firmware version 57.1008.0011 or higher Product manual 8.1008.8001EN / 2021-08-27 Technical Communication Metrohm AG CH-9100 Herisau This documentation…
Key words
input, inputcylinder, cylinderdosing, dosingdefault, defaultvalue, valuetitration, titrationoff, offparameters, parametersunit, unitrange, rangeoperation, operationcontrol, controlrate, ratestart, startfilling
885 Compact Oven SC
2022|Metrohm|Manuals
885 Compact Oven SC Manual 8.885.8002EN / 2022-04-30 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com 885 Compact Oven SC Manual 8.885.8002EN / 2022-04-30 Technical Communication Metrohm AG CH-9100 Herisau This documentation is protected by copyright.…
Key words
usb, usbnotice, noticedefault, defaultwarning, warningtitration, titrationlift, liftvalue, valuemenu, menuoff, offremote, remoteconditioning, conditioningselection, selectionmounting, mountingrack, rackinput