Evaluating Ion Chromatography Suppression Options
Technical notes | 2018 | Thermo Fisher ScientificInstrumentation
Ion chromatography (IC) is essential for detecting and quantifying ionic species in environmental, pharmaceutical, food safety, and industrial applications. Suppression techniques enhance sensitivity by reducing background conductivity of eluents and improving analyte signal clarity.
The study reviews and compares various suppression approaches for IC, including non-suppressed operation, chemically regenerated suppressors (packed-bed, automatically switching, continuously regenerated), and electrolytically regenerated suppressors (constant current, dynamically regenerated). It aims to clarify benefits, limitations, and application suitability of each technique.
A comparative analysis was conducted based on key performance metrics such as baseline noise, suppression capacity, regeneration downtime, chromatographic performance, and compatibility with gradient eluents. Representative system configurations and performance data were drawn from Thermo Fisher Scientific instruments and columns.
By selecting an appropriate suppression technique, laboratories can optimize sensitivity, reproducibility, and operational efficiency. Dynamic regeneration is particularly advantageous for trace analysis, gradient separations, and minimizing labor and reagent costs.
Advancements may include further miniaturization of suppressor modules, enhanced compatibility with organic solvents, integration with mass spectrometric detection, and AI-driven adaptive control of suppression parameters to maximize performance in real time.
A clear understanding of suppression options enables analysts to tailor IC systems to their specific analytical requirements. Thermo Fisher Scientific provides a comprehensive portfolio of suppression technologies, with dynamically regenerated suppressors offering a balanced solution for high-sensitivity and high-throughput applications.
Ion chromatography
IndustriesManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Ion chromatography (IC) is essential for detecting and quantifying ionic species in environmental, pharmaceutical, food safety, and industrial applications. Suppression techniques enhance sensitivity by reducing background conductivity of eluents and improving analyte signal clarity.
Objectives and Study Overview
The study reviews and compares various suppression approaches for IC, including non-suppressed operation, chemically regenerated suppressors (packed-bed, automatically switching, continuously regenerated), and electrolytically regenerated suppressors (constant current, dynamically regenerated). It aims to clarify benefits, limitations, and application suitability of each technique.
Methodology and Instrumentation
A comparative analysis was conducted based on key performance metrics such as baseline noise, suppression capacity, regeneration downtime, chromatographic performance, and compatibility with gradient eluents. Representative system configurations and performance data were drawn from Thermo Fisher Scientific instruments and columns.
Instrumentation Used
- Ion chromatography systems: Dionex ICS-6000, ICS-4000, Integrion
- Columns: Dionex IonPac CS and AS series, Dionex CR-ATC 600 trap column
- Eluent generation and delivery: EGC-500 eluent cartridge, high-pressure degasser, suppressors AERS 500, ADRS 600
- Detection: suppressed and non-suppressed conductivity cells
Main Results and Discussion
- Non-suppressed IC delivers simple setup but limited sensitivity and selectivity due to high background conductivity.
- Packed-bed suppressors achieve high sensitivity but introduce significant dead volume and require lengthy offline chemical regeneration.
- Automatically switching packed-bed suppressors reduce downtime via cartridge rotation but suffer limited capacity per analysis and traceability challenges.
- Continuously regenerated suppressors offer effectively unlimited capacity but mandate continuous preparation or supply of regenerant solutions.
- Constant current electrolytic suppressors eliminate chemical reagents and labor but may generate higher noise with concentration gradients and are incompatible with organic solvents.
- Dynamically regenerated electrolytic suppressors adapt applied current to eluent composition, minimizing noise, simplifying setup, and ensuring optimal performance across gradients.
Benefits and Practical Applications
By selecting an appropriate suppression technique, laboratories can optimize sensitivity, reproducibility, and operational efficiency. Dynamic regeneration is particularly advantageous for trace analysis, gradient separations, and minimizing labor and reagent costs.
Future Trends and Opportunities
Advancements may include further miniaturization of suppressor modules, enhanced compatibility with organic solvents, integration with mass spectrometric detection, and AI-driven adaptive control of suppression parameters to maximize performance in real time.
Conclusion
A clear understanding of suppression options enables analysts to tailor IC systems to their specific analytical requirements. Thermo Fisher Scientific provides a comprehensive portfolio of suppression technologies, with dynamically regenerated suppressors offering a balanced solution for high-sensitivity and high-throughput applications.
References
- Moore DG. Evaluating Ion Chromatography Suppression Options. Thermo Fisher Scientific White Paper 72753 (2018).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Dionex eluent suppressors for ion chromatography
2022|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS Thermo Scientific Dionex eluent suppressors for ion chromatography Suppression was introduced in 1975, thereby bringing ion chromatography (IC) to the forefront of modern analytical techniques for inorganic analysis. Suppression greatly enhances signal-to-noise ratio by: • Decreasing background eluent…
Key words
regenerant, regenerantsuppressor, suppressordionex, dionexeluent, eluenteluents, eluentssuppression, suppressioncarbonate, carbonateexchange, exchangetba, tbaregenerated, regeneratedion, ionconductivity, conductivitynoise, noisesuppressors, suppressorsanion
Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities
2016|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities The power to increase productivity RFIC System Technology Since the introduction of eluent generation in 1998, Thermo Fisher Scientific has continued to simplify ion chromatography (IC) while expanding the capabilities and…
Key words
eluent, eluentrfic, rficdionex, dionexcarbonate, carbonatekoh, kohgeneration, generationsuppressor, suppressorelectrolytically, electrolyticallyregenerated, regeneratedhydroxide, hydroxideegc, egcsystems, systemsminutes, minutesconductivity, conductivitycartridge
What is the Role of a Next Generation Suppressor?
2013|Thermo Fisher Scientific|Technical notes
John Madden and Monika Verma Thermo Fisher Scientific, Sunnyvale, CA, USA Executive Summary Suppression technology is the heart of an ion chromatography (IC) system. Previous advances in suppressor functionality have focused on continuous operation, achieving high-capacity and ease-of-use. Advances in…
Key words
suppressor, suppressorregenerant, regenerantsuppressors, suppressorsregenerated, regeneratedgenerations, generationsexchange, exchangechannel, channelprevious, previouselectrode, electrodeeluent, eluentwhat, whation, ionelastomeric, elastomericregeneration, regenerationplate
Eluent Suppressors for Ion Chromatography
2016|Thermo Fisher Scientific|Technical notes
suppressors Eluent Suppressors for Ion Chromatography Dionex introduced suppression in 1975, thereby bringing ion chromatography (IC) to the forefront of modern analytical techniques for inorganic analysis. Suppression greatly enhances signal-to-noise ratio in two ways by: • • Decreasing background eluent…
Key words
regenerant, regenerantsuppressor, suppressoreluent, eluenteluents, eluentsexchange, exchangesuppression, suppressionregeneration, regenerationatlas, atlasion, ionsuppressors, suppressorssrs, srscation, cationaes, aestba, tbanoise