Thermo Scientific Dionex UltiMate 3000 Series SRD-3x00 Solvent Racks Operating Instructions
Manuals | 2013 | Thermo Fisher ScientificInstrumentation
The reliable removal of dissolved gases from HPLC solvents is critical to achieving stable baselines, reproducible retention times and extended column and pump lifetime. An integrated solvent rack with vacuum membrane degassing streamlines solvent handling, reduces bubble‐induced noise and enhances overall chromatographic performance in both routine and high‐end analytical laboratories.
This document presents a comprehensive guide for the Thermo Scientific Dionex UltiMate 3000 SRD-3x00 Solvent Rack series. It covers system description, configuration options, safe installation, start-up procedures, routine operation, monitoring functions, preventive maintenance and troubleshooting procedures. Emphasis is placed on seamless integration with UltiMate 3000 HPLC pumps and Chromeleon control software, while also supporting stand-alone operation.
The solvent rack series is available in three analytical degassing configurations (2-, 4- and 6-channel SRD-3200, 3400 and 3600). The key components and procedural steps include:
By following the prescribed installation and startup sequence – from unpacking and environmental checks to connecting solvent reservoirs, piping and power – users achieve rapid commissioning. Continuous vacuum level monitoring ensures that each channel is maintained at optimal degassing performance, while the leak sensor provides a visual and software-based alert in case of fluid ingress. Chromeleon diagnostics validate degasser health, and integrated menus on the UltiMate pump or within software allow on/off control and automated recovery after power interruptions. Routine rinsing procedures with acid and organic solvents restore membrane efficiency and prevent ghost peaks.
Advances may include higher channel counts for ultra-high throughput, novel membrane materials for broader solvent compatibility, integration of predictive maintenance via IoT connectivity and centralized wellness dashboards. Further miniaturization and biocompatible designs will support emerging UHPLC and proteomics workflows.
The UltiMate 3000 SRD-3x00 Solvent Rack family provides a turnkey solution for solvent management and degassing in modern HPLC systems. Its thoughtful engineering, modular integration and advanced monitoring features address key challenges in chromatographic analysis and set a benchmark for reliability, user safety and system performance.
HPLC
IndustriesManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
The reliable removal of dissolved gases from HPLC solvents is critical to achieving stable baselines, reproducible retention times and extended column and pump lifetime. An integrated solvent rack with vacuum membrane degassing streamlines solvent handling, reduces bubble‐induced noise and enhances overall chromatographic performance in both routine and high‐end analytical laboratories.
Study Objectives and Overview
This document presents a comprehensive guide for the Thermo Scientific Dionex UltiMate 3000 SRD-3x00 Solvent Rack series. It covers system description, configuration options, safe installation, start-up procedures, routine operation, monitoring functions, preventive maintenance and troubleshooting procedures. Emphasis is placed on seamless integration with UltiMate 3000 HPLC pumps and Chromeleon control software, while also supporting stand-alone operation.
Methodology and Instrumentation
The solvent rack series is available in three analytical degassing configurations (2-, 4- and 6-channel SRD-3200, 3400 and 3600). The key components and procedural steps include:
- Amorphous fluoropolymer membrane degassing chambers (670 μL each) with dedicated vacuum pump and exhaust port
- PEEK, FEP and ETFE/ECTFE flow paths with frit filters (10 μm stainless steel, PEEK or titanium) to protect against particulate contamination
- Integrated leak sensor beneath the drip tray for early liquid detection
- Electrical interface via 15-pin D-sub to UltiMate 3000 pumps or optional external 24 V DC supply for stand-alone use
- Control and monitoring of degasser vacuum, leak status and power via front-panel LEDs, pump display or Chromeleon software
Main Results and Discussion
By following the prescribed installation and startup sequence – from unpacking and environmental checks to connecting solvent reservoirs, piping and power – users achieve rapid commissioning. Continuous vacuum level monitoring ensures that each channel is maintained at optimal degassing performance, while the leak sensor provides a visual and software-based alert in case of fluid ingress. Chromeleon diagnostics validate degasser health, and integrated menus on the UltiMate pump or within software allow on/off control and automated recovery after power interruptions. Routine rinsing procedures with acid and organic solvents restore membrane efficiency and prevent ghost peaks.
Benefits and Practical Applications
- Space-saving modular design stacks directly onto UltiMate 3000 pumps
- Automatic and continuous removal of dissolved gases reduces baseline drift and pulsation
- Leak detection and vacuum monitoring enhance system safety and uptime
- Compatibility with a wide range of HPLC solvents and buffers via robust polymer and metal components
- Flexible control modes: direct pump integration, Chromeleon software or stand-alone operation
Future Trends and Possibilities
Advances may include higher channel counts for ultra-high throughput, novel membrane materials for broader solvent compatibility, integration of predictive maintenance via IoT connectivity and centralized wellness dashboards. Further miniaturization and biocompatible designs will support emerging UHPLC and proteomics workflows.
Conclusion
The UltiMate 3000 SRD-3x00 Solvent Rack family provides a turnkey solution for solvent management and degassing in modern HPLC systems. Its thoughtful engineering, modular integration and advanced monitoring features address key challenges in chromatographic analysis and set a benchmark for reliability, user safety and system performance.
Použitá instrumentace
- Thermo Scientific Dionex UltiMate 3000 SRD-3x00 Solvent Rack (models SRD-3200/3400/3600)
- Integrated vacuum pump and amorphous fluoropolymer degasser membranes
- PEEK, FEP, ETFE/ECTFE flow paths with 10 μm frit filters (stainless steel PEEX or titanium)
- 15-pin D-sub control interface to UltiMate 3000 pumps or 24 V DC external power supply unit
- Chromeleon Chromatography Data System for remote control, diagnostics and audit trail
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Dionex UltiMate 3000 Series - SD, RS, BM, and BX Pumps
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series SD, RS, BM, and BX Pumps Operating Instructions (Original Operating Instructions) Revision: 1.7 Date: September 2013 © 2013 Thermo Fisher Scientific Doc. No. 4820.4001 UltiMate 3000 Series: SD, RS, BM, and BX Pumps Operating…
Key words
instructions, instructionsoperating, operatingpump, pumpseal, sealwash, washpiston, pistonhead, headcylinder, cylinderincluded, includedpurge, purgepressure, pressurerear, rearchromeleon, chromeleonvalve, valvepumps
Thermo Scientific Dionex UltiMate 3000 Series Nano/Cap System NCS-3500RS Nano/Cap Pump NCP-3200RS Operating Instructions
2016|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series Nano/Cap System NCS-3500RS Nano/Cap Pump NCP-3200RS Operating Instructions (Original Operating Instructions) Revision: 2.0 Date: January 2016 © 2016 Thermo Fisher Scientific Inc. Doc No. 4820.4101 UltiMate 3000 Series: NCS-3500RS and NCP-3200RS Operating Instructions UltiMate…
Key words
instructions, instructionspump, pumpoperating, operatingmeter, metermodule, moduleflow, flowseal, sealpressure, pressurehead, headvalve, valveloading, loadingproflow, proflowchromeleon, chromeleonpurge, purgesolvent
Thermo Scientific Dionex UltiMate 3000 Series SR-3000 Solvent Rack Operating Instructions
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series SR-3000 Solvent Rack Operating Instructions (Original Operating Instructions) Revision: 1.7 Date: September, 2013 © 2013 Thermo Fisher Scientific Inc. Doc. No. 4820.3555 *4820.3555* UltiMate 3000 Series: SR-3000 Solvent Rack Operating Instructions UltiMate 3000 Series:…
Key words
instructions, instructionsoperating, operatingdes, despour, pourles, lessolvants, solvantsune, unecap, caprack, rackcapillaires, capillaireséviter, éviterpeut, peutbottle, bottlesolvent, solventholes
Thermo Scientific Dionex UltiMate 3000 Series Autosampler Column Compartment ACC-3000
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series Autosampler Column Compartment ACC-3000 Operating Instructions (Original Operating Instructions) Revision: 1.4 Date: September 2013 © 2013 Thermo Fisher Scientific Doc No. 4828.3050 UltiMate 3000 Series: ACC-3000 Autosampler Column Compartment Operating Instructions UltiMate 3000 Series:…
Key words
instructions, instructionsoperating, operatingautosampler, autosamplerchromeleon, chromeleonsyringe, syringeneedle, needleturn, turnpressing, pressingwash, washpower, powerloop, loopvalve, valvedes, desagain, againcarousel