LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

ToxProPlus Reporting Software Package

Manuals | 2005 | Agilent TechnologiesInstrumentation
Software
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Accurate and efficient reporting of GC/MS data is critical for analytical laboratories to ensure data integrity, facilitate rapid decision making, and support regulatory compliance. Customizable software tools streamline the review of chromatographic and spectral results, enabling both novice and experienced users to tailor reports to specific workflows and quality assurance requirements.

Objectives and Overview


This document summarizes Varian’s suite of reporting solutions designed for use with the Varian MS Workstation and Saturn GC/MS platforms. It introduces three main software packages—ToxProPlus, MultiCpd, and Screening Reports—as well as an Ion Ratio Summary tool. Each package provides unique report templates and controls for interactive review and automated generation of textual and graphical outputs.

Methodology and Used Instrumentation


The reporting applications are based on Microsoft Access databases and require data processed by Varian MS Workstation version 6.5 or later. Key components include:
  • Saturn GC/MS Workstation with Metis data acquisition and MS Data Review modules
  • Microsoft Access 2000–based report templates (.mdb files) and working template files (.swt extension)
  • ToxProPlus package for predefined screening, ion ratio, and MultiCpd summary reports
  • MultiCpd software for detailed graphic and text reports of target, unknown, and tentatively identified compounds
  • Screening Reports for rapid visual review of up to 30 target analytes per page
  • Ion Ratio Summary tool for quick calibration and qualifier-ion ratio performance checks

Main Features and Discussion


The reporting tools share a common architecture: templates define report layout, graphics, and text fields; working templates drive interactive or automated output. Key capabilities include:
  • Flexible graphic types: chromatograms, spectra, overlay or stacked traces, up to 16 frames per page
  • Configurable text fields: choice of quantitation results, ion ratios, fit values, error codes
  • Preformatted report templates: Screening (2×2, 3×3, 4×4 grids), Chromatogram (1–3 segments), Target Compound graphics/text, Unknowns, and TIC summaries
  • Header and footer customization: titles, logos, instrument logs, calibration and acquisition details
  • Integration with Sample and Recalc lists for automated report printing via AutoLink
  • Export of text-only reports to delimited text files for external processing

Benefits and Practical Applications


These reporting solutions accelerate method development and routine analysis by providing rapid visual screening of analyte peaks, early detection of integration or quantitation issues, and streamlined final report generation. Laboratories benefit from:
  • Reduced turnaround time through post-run screening and ion ratio checks
  • Consistent, compliant reporting formats for QA/QC and regulatory audits
  • Customization to accommodate varying analyte panels and sample types
  • Automated workflows that integrate acquisition, data processing, and report printing

Future Trends and Opportunities


Emerging directions include cloud-based report management, integration with laboratory information management systems (LIMS), and AI-driven quality control that automatically flags anomalies. Enhancements in graphical reporting, real-time dashboarding, and support for high-resolution MS data will further expand the utility of custom reporting tools.

Conclusion


Varian’s custom reporting software—ToxProPlus, MultiCpd, Screening Reports, and Ion Ratio Summary—offers a comprehensive framework for generating expert-level GC/MS reports. By leveraging template-based design, these tools balance ease of use with advanced customization, supporting both rapid data review and detailed documentation of analytical results.

Reference


1 Varian, Inc. ToxProPlus Reporting Software Package, Version 6.5, 2005
2 Varian, Inc. MultiCpd Reports, Version 6.5, 2005
3 Varian, Inc. Ion Ratio Summary Report Software, Version 6.5, 2005
4 Varian, Inc. Screening Reports Software Package, Version 6.5, 2005

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent Technologies Agilent MassHunter Workstation Software Report Designer Add-in
Agilent MassHunter Workstation Software Report Designer Add-in Quick Start Guide What is the Agilent MassHunter Workstation Software Report Designer Add-in? 2 Report Designer UI elements 3 Getting Started 5 Customizing a template 13 Using the Advanced Properties dialog box 24…
Key words
designer, designeradd, addreport, reportmasshunter, masshuntertemplate, templateguide, guideagilent, agilentquick, quickstart, startcustomizing, customizingtable, tableworkstation, workstationgraphics, graphicsgetting, gettingmenu
PolyView2000
PolyView2000
2002|Agilent Technologies|Manuals
NOTICE: Varian, Inc. was acquired by Agilent Technologies in May 2010. This document is provided as a courtesy but is no longer kept current and thus will contain historical references to Varian. For more information, go to www.agilent.com/chem. Varian Analytical…
Key words
window, windowspectra, spectrareport, reportlibrary, librarypeak, peakmanager, managerpurity, purityreports, reportssensing, sensingmca, mcadialog, dialogmau, maupup, pupspectrum, spectrumoperation
Compound Discoverer 1.0 Reporting Quick Start
Compound Discoverer 1.0 Reporting Quick Start
2014|Thermo Fisher Scientific|Manuals
Compound Discoverer 1.0 Reporting Quick Start This guide shows you how to open a result file, create a new report template, modify an existing report template, and print a report. You can perform these tasks without an active software license.…
Key words
report, reporttemplate, templatedialog, dialogtranspose, transposepreview, previewitem, itembox, boxrows, rowsmaster, masterdata, dataprint, printicon, iconopen, opentextbox, textboxdesign
MestReNova Manual
MestReNova Manual
2024|SciY/Mestrelab Research|Manuals
MestReNova Manual © 2023 M ESTRELAB RESEARCH Last Revision: 21st Feb 2024 MestReNova 15.0.1 by MESTRELAB RESEARCH This is the manual of MestReNova 15.0.01 MestReNova © 2024 MESTRELAB RESEARCH All rights reserved. No parts of this work may be reproduced…
Key words
mestrenova, mestrenovamnova, mnovayou, younmr, nmrclicking, clickingmschrom, mschrommultiplet, multipletspectrum, spectrummenu, menumultiplets, multipletsprocessing, processingcan, canspectra, spectraprediction, predictionstacked
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike