Manuals | 2008 | Agilent TechnologiesInstrumentation
Consumables, LC columns
Industries
Manufacturer
Agilent Technologies

Summary

EcoSpheres User Guide: Gel Permeation Chromatography Cleanup



Importance of the Topic


Environmental analysis often requires the removal of interfering high molecular weight components such as fats and lipids from complex matrices. Gel permeation chromatography (GPC) provides a reliable size‐based separation to isolate low molecular weight hydrophobic analytes for further analysis. EcoSpheres, a crosslinked polystyrene‐divinylbenzene resin, offers a tailored stationary phase optimized for environmental sample cleanup, improving analytical accuracy and throughput.

Objectives and Product Overview


EcoSpheres are designed to simplify the cleanup of environmental extracts by size exclusion. The main goals are:
  • Efficient separation of low molecular weight (LMW) hydrophobic compounds from high molecular weight (HMW) interferences
  • Compatibility with a variety of organic solvents for swelling and elution
  • Ease of column preparation and regeneration for routine laboratory use

The product consists of uniform spherical beads with a controlled pore structure. By selecting appropriate swelling solvents, users can adjust pore volume and molecular weight exclusion limits to suit target analytes.

Methodology and Used Instrumentation


Preparation and operation of EcoSpheres columns involve several key steps:
  1. Swell the dry resin in excess organic solvent (e.g., toluene, xylene, dichloromethane, ethyl acetate, tetrahydrofuran) for at least six hours to maximize pore formation.
  2. Prepare a 25 mm ID, 300–400 mm adjustable‐end glass or stainless steel GPC column, washing it with the swelling solvent and fitting appropriate frits and seals.
  3. Form a uniform slurry of swollen beads and solvent, then pour into the vertically clamped column in small increments, allowing solvent drainage to achieve an even packed bed.
  4. Attach the top fitting and pump the swelling solvent from bottom to top at 5 mL/min for ten minutes to settle the bed and remove any voids.
  5. Adjust end fittings to eliminate air pockets, and maintain continuous solvent flow to prevent drying or channeling.

Recommended operating conditions:
  • Flow rate: 5–10 mL/min
  • Maximum backpressure: up to 1 MPa

Regeneration can be performed by reswelling in strong aromatic solvents, repacking, and flushing with three column volumes of solvent.

Used Instrumentation


  • Preparation: Glass or stainless steel adjustable GPC column (25 mm ID, 300–400 mm length)
  • Pumping system capable of 5–10 mL/min flow and 1 MPa pressure
  • Organic solvent reservoirs and degassing equipment
  • Fraction collector for eluent collection

Main Principles and Operation


EcoSpheres separate components based on their ability to enter the bead pores:
  • Large molecules above the exclusion limit are excluded from pores and elute rapidly.
  • Small molecules penetrate the pore network and elute later, achieving fractionation by size.
  • The mobile phase is the flowing eluent, while the stationary phase is the solvent retained within the pore structure.

This size‐exclusion mechanism provides reproducible retention behavior controlled by bead swelling and solvent choice.

Benefits and Practical Applications


EcoSpheres offer several advantages for environmental and industrial laboratories:
  • High chemical resistance, compatible with a broad range of organic solvents
  • Reproducible bead size and pore structure for consistent separations
  • Simple column packing and regeneration procedures reduce downtime
  • Improved cleanup of pesticide, PAH, and lipid‐rich samples prior to GC or LC analysis

Future Trends and Applications


Advances in GPC cleanup may include:
  • Integration with automated sample preparation platforms to increase throughput
  • Development of miniaturized EcoSphere formats for micro‐GPC and on‐line coupling to mass spectrometry
  • Tailored copolymer chemistries to extend solvent compatibility and fine‐tune exclusion limits
  • Recycling and green solvent approaches to reduce environmental impact

Conclusion


EcoSpheres resin provides a robust and versatile solution for size‐based separation of low and high molecular weight species in environmental sample cleanup. Through careful selection of swelling solvents, precise column packing, and controlled operating conditions, laboratories can achieve reliable fractionation for downstream analyses. The method’s chemical resilience, ease of regeneration, and compatibility with standard GPC systems make EcoSpheres a practical choice for routine sample preparation workflows.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Chlorinated Compounds in Linseed Oil Analyzed with Agilent EcoSpheres
Chlorinated Compounds in Linseed Oil Analyzed with Agilent EcoSpheres Application Note Food Testing and Agriculture Author Introduction Graham Cleaver Linseed is the seed of the flax plant Linum usitatissimum L., Linaceae. Its oil is derived from the seed by cold-pressing.…
Key words
linseed, linseedecospheres, ecospherestrichlorobenzene, trichlorobenzeneoil, oilgpc, gpcspiked, spikedmolecules, moleculesdatasteam, datasteamcirrus, cirrussmaller, smalleragilent, agilentcleaver, cleavergraham, grahamattempts, attemptsfood
Sample Clean-up by Gel Permeation Chromatography Using Agilent EcoSpheres
Sample Clean-up by Gel Permeation Chromatography Using Agilent EcoSpheres Application Note Food Testing and Agriculture Author Introduction Graham Cleaver Governments around the world require the analysis of environmental and food samples for a wide range of contaminants that potentially threaten…
Key words
ecospheres, ecospheresgpc, gpcclean, cleandatasteam, datasteamcirrus, cirrusthreaten, threatenepa, eparemoval, removalinterferences, interferencesmicroporous, microporousagilent, agilentgovernments, governmentsswelling, swellingcleaver, cleavergraham
Gel Permeation Chromatography and Size Exclusion Chromatography Reference Guide
Eluent transfer guide for Agilent PLgel/Agilent PlusPore 7.5 mm ID column PLgel and PlusPore columns can be transferred easily and rapidly between solvents of varying polarity. Column supplied in ethylbenzene Transfer to: hexane perfluoroalkanes dichloromethane MEK ethylacetate chloroform 1. Flush…
Key words
gpc, gpcsec, secpolymer, polymerpolystyrene, polystyrenepolymethyl, polymethylcoils, coilscolumns, columnsmethacrylate, methacrylatemolecular, molecularsize, sizedetectors, detectorspolysaccharide, polysaccharidepolyethylene, polyethylenepolar, polarpluspore
Separation of Trichlorobenzene from Sardines using Agilent EcoSpheres
Separation of Trichlorobenzene from Sardines using Agilent EcoSpheres Application Note Author Introduction Graham Cleaver Agilent Technologies, Inc. The analysis of pesticides and other contaminants in environmental samples is an important part of monitoring the condition of the environment. For example,…
Key words
ecospheres, ecospheressardine, sardinesardines, sardinesmacerated, maceratedcontaminant, contaminanttrichlorobenzene, trichlorobenzeneclean, cleangpc, gpcagilent, agilentdatastream, datastreamrevealed, revealedmolecular, molecularpacking, packingcirrus, cirrusmicroporous