Applications | 2022 | ShimadzuInstrumentation
HPLC
Industries
Food & Agriculture, Energy & Chemicals
Manufacturer
Shimadzu

Summary

Význam tématu


Food additives often include synthetic colorants to enhance visual appeal. Rapid and reliable analysis of these dyes is essential for quality control and regulatory compliance. High-speed reversed-phase HPLC methods offer efficient separation and quantification of multiple dyes in a short analysis time.

Cíle a přehled studie


The study aims to develop a fast and robust chromatographic method for simultaneous detection of twelve common artificial food dyes at 50 mg/L each. Using Shimadzu Nexera XR and Shim-pack Scepter C18-120 column, the protocol targets a total runtime below five minutes.

Použitá metodika a instrumentace


  • System Nexera XR
  • Column Shim-pack Scepter C18-120, 100 mm L, 3.0 mm I.D., 1.9 μm
  • Mobile phase A 10 mmol/L ammonium acetate, B 10 mmol/L ammonium acetate/acetonitrile 1/1 (v/v)
  • Gradient 10% B to 100% B in 4 minutes, re-equilibration to initial conditions by 10 minutes
  • Flow rate 0.9 mL/min, column temperature 40 °C, injection volume 5 μL
  • Detection PDA at 254 nm and 630 nm

Hlavní výsledky a diskuse


Separation of all twelve dyes was achieved within 4 minutes with baseline resolution. Dual wavelength detection provided optimal sensitivity for different dye classes: aromatic dyes at 254 nm and azo/triarylmethane dyes at 630 nm. Peak shapes were sharp thanks to sub-2 μm particles, and method robustness was confirmed by reproducible retention times and peak areas across repeated injections.

Přínosy a praktické využití metody


Rapid screening of multiple synthetic colorants improves laboratory throughput and reduces solvent consumption. The method is well suited for routine quality control in the food industry and regulatory laboratories. Dual detection wavelengths enable direct confirmation of dye identity and accurate quantification without derivatization.

Budoucí trendy a možnosti využití


Integration with high-throughput autosamplers and multiplexed detection systems could further enhance productivity. Coupling HPLC with mass spectrometry may offer increased selectivity and structural confirmation. Advances in column technology and greener mobile phase formulations are expected to reduce environmental impact and operational costs.

Závěr


The developed reversed-phase HPLC method delivers fast, reliable analysis of a wide range of artificial food dyes in under five minutes. Its combination of high efficiency, reproducibility and dual-wavelength detection supports robust quality assurance workflows in food analysis.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Method Scouting for Simultaneous Analysis of Twelve Tar Dyes
High Performance Liquid Chromatograph Application News i-Series/LC-2060C 3D Method Scouting for Simultaneous Analysis of Twelve Tar Dyes Yiting Zhou User Benefits  Batch schedules for scouting different analytical conditions can be created automatically using Method Scouting Solution.  Multiple mobile…
Key words
scouting, scoutingtar, tarmau, mautwelve, twelveblending, blendingmobile, mobilesimultaneous, simultaneousdyes, dyesconditions, conditionsnews, newsmethod, methodfunction, functionevaluation, evaluationphase, phasereport
Analysis of Synthetic Dye
Analysis of Synthetic Dye
2025|Shimadzu|Applications
ERAS-1000-0595 LC Reversed-phase Shim-packTM Series Shim-pack NovaCore C18-HB Analysis of Synthetic Dye 595 Keywords: cosmetics, food coloring, color additives mAU 3 900 800 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 10 700 4 600 1…
Key words
dye, dyepacktm, packtmshim, shimphase, phasesynthetic, syntheticmau, maureversed, reversedseries, seriesprogram, programgradient, gradientmobile, mobilevolume, volumerate, rateinjection, injectiondetection
Simultaneous Analysis of Synthetic Colorants, Including Red No. 3, Using an Organic Silica Hybrid Core-Shell Column
Software for Efficient Method Development “LabSolutions MD” Organic Silica Hybrid Core-Shell Column “Shim-pack NovaCore C18-HB” Application News Simultaneous Analysis of Synthetic Colorants, Including Red No. 3, Using an Organic Silica Hybrid Core-Shell Column Shinichi Fujisaki User Benefits  The organic…
Key words
colorants, colorantstwelve, twelvetar, tarsynthetic, syntheticsolvent, solventshell, shellorganic, organicmobile, mobileseparation, separationoptimization, optimizationporous, porouscore, corecolumn, columnpump, pumpcomposition
Oligonucleotide analysis by Ion-pair Reversed Phase Chromatography
ERAS-1000-0077 LC Reversed-phase Shim-packTM Series Shim-pack ScepterTM C18-120 [metal-free] Oligonucleotide analysis by Ion-pair Reversed Phase Chromatography 77 Keywords: nucleic acid, nucleotide, poly T, inert system, inert column uV T(30) 35000 T(25) 32500 30000 T(18) T(20) T(17) T(19) 27500 25000 T(15)…
Key words
phase, phasereversed, reversednexeratm, nexeratmpacktm, packtmmobile, mobileoligonucleotide, oligonucleotideshim, shimpair, pairinert, inertseries, seriesprogram, programvolume, volumerate, rateion, ioninjection
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike