Analysis of Salidroside in Ligustrum (Shim-pack GIS C18)
Applications | 2023 | ShimadzuInstrumentation
Salidroside is a phenolic glycoside found in Ligustrum species with potential biological activities such as adaptogenic and antioxidant effects. Reliable quantification of salidroside in plant materials is essential for quality control in herbal products and pharmaceutical applications.
The study aims to develop a simple and robust reversed-phase liquid chromatography method to determine salidroside content in Ligustrum powder. A Shim-pack GIS C18 column with isocratic elution and UV detection at 275 nm was evaluated using a standard mix and actual sample extracts.
The method provided clear separation of salidroside with consistent retention times between standards and samples. Calibration at 70 µg/mL demonstrated reproducible peak shapes and reliable quantification. The isocratic system reduced solvent use and analysis time while maintaining adequate resolution.
Future developments may include coupling with mass spectrometry for enhanced sensitivity and specificity, adoption of greener solvents to reduce environmental impact, and automation of sample preparation to boost throughput and reproducibility.
The presented reversed-phase LC method using Shim-pack GIS C18 effectively quantifies salidroside in Ligustrum powder. Its robustness, simplicity, and cost efficiency make it a valuable tool for quality assessment in herbal and pharmaceutical contexts.
Consumables, HPLC, LC columns
IndustriesFood & Agriculture
ManufacturerShimadzu
Summary
Importance of the topic
Salidroside is a phenolic glycoside found in Ligustrum species with potential biological activities such as adaptogenic and antioxidant effects. Reliable quantification of salidroside in plant materials is essential for quality control in herbal products and pharmaceutical applications.
Objectives and Study Overview
The study aims to develop a simple and robust reversed-phase liquid chromatography method to determine salidroside content in Ligustrum powder. A Shim-pack GIS C18 column with isocratic elution and UV detection at 275 nm was evaluated using a standard mix and actual sample extracts.
Methodology and Instrumentation
- Sample pretreatment: 0.5 g Ligustrum powder extracted with 70% methanol under ultrasonic conditions (500 W, 40 kHz, 30 min), followed by dilution to original weight and filtration.
- Chromatographic conditions:
- Column: Shim-pack GIS C18 (250 mm x 4.6 mm I.D., 5 μm).
- Mobile phase: water/methanol = 85:15 (v/v), isocratic elution.
- Flow rate: 1.0 mL/min; Column temperature: 40 °C; Injection volume: 10 µL.
- Detection: UV at 275 nm.
Key Results and Discussion
The method provided clear separation of salidroside with consistent retention times between standards and samples. Calibration at 70 µg/mL demonstrated reproducible peak shapes and reliable quantification. The isocratic system reduced solvent use and analysis time while maintaining adequate resolution.
Benefits and Practical Applications
- Simple and reproducible sample preparation suitable for routine quality control.
- Cost-effective analysis with isocratic elution complements high-throughput environments.
- Applicability to herbal product standardization and regulatory compliance workflows.
Future Trends and Opportunities
Future developments may include coupling with mass spectrometry for enhanced sensitivity and specificity, adoption of greener solvents to reduce environmental impact, and automation of sample preparation to boost throughput and reproducibility.
Conclusion
The presented reversed-phase LC method using Shim-pack GIS C18 effectively quantifies salidroside in Ligustrum powder. Its robustness, simplicity, and cost efficiency make it a valuable tool for quality assessment in herbal and pharmaceutical contexts.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Salidroside in Ligustrum (Shim-pack VP-ODS)
2023|Shimadzu|Applications
ERAS-1000-0037 LC Reversed-phase Shim-pack Series Shim-packTM VP-ODS Analysis of Salidroside in Ligustrum 37 Keywords: Rhodioloside, Phenolic glycosides, Glycoside, Rhodosin Chromatogram of Standard Mix 1. Salidroside Standard Salidroside (70 μg/mL in Methanol) Chromatogram of Ligustrum Column Mobile phase Flow rate Column…
Key words
ligustrum, ligustrumshim, shimsalidroside, salidrosidestoppered, stopperedultrasonically, ultrasonicallystopper, stopperchromatogram, chromatogramshake, shakepacktm, packtmtreat, treatods, odsbring, bringpowder, powdercollect, collectphase
Analysis of Paeoniflorin in Red Peony Root
2023|Shimadzu|Applications
ERAS-1000-0005 LC Reversed-phase Shim-pack Series Shim-packTM GIS C18 Analysis of Paeoniflorin in Red Peony Root 5 Keywords: Herbal medicine, Glycoside Chromatogram of Standard Mix Paeoniflorin reference 1 Chromatogram of Red Peony Root 1 Column Mobile phase Flow rate Column Temp.…
Key words
peony, peonypaeoniflorin, paeoniflorinroot, rootstoppered, stopperedred, redconical, conicalchromatogram, chromatogramshim, shimphase, phasepack, packpretreatment, pretreatmentstandard, standardmix, mixreversed, reversedvial
Analysis of Binapacryl and Loganin in Six Ingredient Pills with Rehmannia
2023|Shimadzu|Applications
ERAS-1000-0002 LC Reversed-phase Shim-pack Series Shim-packTM GIS C18 Analysis of Binapacryl and Loganin in Six Ingredient Pills with Rehmannia 2 Keywords: Pesticide, Glycoside, Herbal medicine Chromatogram of Standard Mix 2 Standard Mix Morocide Loganin (20 μg/mL in Methanol) 1 Chromatogram…
Key words
rehmannia, rehmannialoganin, loganinpills, pillsmorocide, morocideingredient, ingredientbinapacryl, binapacrylmix, mixreflux, refluxgrind, grindweight, weightchromatogram, chromatogramshim, shimphase, phasepack, packpretreatment
Analysis of Paeoniflorin in Bazhenyimu Pill
2023|Shimadzu|Applications
ERAS-1000-0004 LC Reversed-phase Shim-pack Series Shim-packTM GIS C18 Analysis of Paeoniflorin in 4 Bazhenyimu Pill Keywords: Glycoside, Herbal medicine Chromatogram of Standard Mix 1. Paeoniflorin 1 Chromatogram of Bazhenyimu Pill 1 Column Mobile phase Gradient program Flow rate Column Temp.…
Key words
bazhenyimu, bazhenyimupill, pillpaeoniflorin, paeoniflorinmix, mixgrind, grindchromatogram, chromatogramfine, fineshim, shimphase, phasepack, packpretreatment, pretreatmentstandard, standardreversed, reversedvial, vialseries