Characterization of Poly(ethylene oxide)
Applications | 2023 | Agilent TechnologiesInstrumentation
Poly(ethylene oxide) (PEO) and its lower-molecular-weight counterpart poly(ethylene glycol) (PEG) are widely used in pharmaceuticals, biotechnology, and materials science. Accurate characterization of their molar mass and distribution is critical for ensuring product performance, batch-to-batch consistency, and regulatory compliance. Gel permeation chromatography (GPC/SEC) remains a standard technique for polymer analysis, offering reliable molar mass determination when coupled with appropriate columns, detectors, and calibration standards.
This application note aims to demonstrate a GPC method for PEO/PEG characterization using PSS SUPREMA columns and refractive index detection. Key goals include establishing optimized chromatographic conditions, recommending sample preparation guidelines for different polymer dispersities, and validating column sets spanning low to ultra-high molecular weights.
The described GPC method offers a robust, easy-to-implement workflow for routine quality control of PEO/PEG materials. By selecting appropriate column sets and sample concentrations, laboratories can achieve high resolution and accurate molar mass distribution profiles. This approach supports product development, regulatory filing, and comparative analysis of polymer batches.
This application note outlines a validated GPC method for comprehensive characterization of PEO/PEG using PSS SUPREMA columns. Optimized mobile phase conditions, column selections, and sample preparation guidelines enable reliable determination of molar mass distributions from oligomers to ultra-high-molecular-weight polymers. The method supports diverse analytical needs in research, quality control, and process development.
Consumables, LC columns, GPC/SEC
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Poly(ethylene oxide) (PEO) and its lower-molecular-weight counterpart poly(ethylene glycol) (PEG) are widely used in pharmaceuticals, biotechnology, and materials science. Accurate characterization of their molar mass and distribution is critical for ensuring product performance, batch-to-batch consistency, and regulatory compliance. Gel permeation chromatography (GPC/SEC) remains a standard technique for polymer analysis, offering reliable molar mass determination when coupled with appropriate columns, detectors, and calibration standards.
Objectives and Study Overview
This application note aims to demonstrate a GPC method for PEO/PEG characterization using PSS SUPREMA columns and refractive index detection. Key goals include establishing optimized chromatographic conditions, recommending sample preparation guidelines for different polymer dispersities, and validating column sets spanning low to ultra-high molecular weights.
Methodology and Instrumentation
- Mobile Phase: Water containing 0.05% sodium azide to suppress microbial growth and ensure baseline stability.
- Stationary Phase: PSS SUPREMA column series, designed for broad polymer size ranges.
- Flow Rate and Temperature: 1.0 mL/min at 25 °C to balance resolution and analysis time.
- Detection: Shodex RI-71 differential refractive index detector for universal response to PEO/PEG.
- Calibration Standards: ReadyCal kit with PEO standards covering a wide molar mass span.
- Data Processing: PSS WinGPC software for chromatogram integration and molar mass distribution calculation.
Key Results and Discussion
- Elution profiles on PSS SUPREMA columns showed clear separation across 100 Da to over 1,000,000 Da molecular weights.
- Recommended sample concentrations depend on polymer dispersity (PDI):
- Narrow PDI <1.5: 2 g/L for 100–10,000 Da; 1–2 g/L for 10,000–1,000,000 Da; ≤0.5 g/L for >1,000,000 Da.
- Broad PDI >1.5: 3–5 g/L across all molecular weights to improve signal strength.
- Injection volume was fixed at 100 µL to maintain reproducible peak shapes without overloading.
- Column recommendations by molecular weight range:
- Low MW: three-column set (P/N 206-0001) or single linear column (sua083005lis).
- Medium MW: three-column set (P/N 206-0002) or single linear column (sua083005lim).
- High MW: three-column set (P/N 206-0003) or single linear column (sua083010lxl).
- Ultra-high MW: three-column set (P/N 206-0004) or single linear column (sua083010luh).
Benefits and Practical Applications
The described GPC method offers a robust, easy-to-implement workflow for routine quality control of PEO/PEG materials. By selecting appropriate column sets and sample concentrations, laboratories can achieve high resolution and accurate molar mass distribution profiles. This approach supports product development, regulatory filing, and comparative analysis of polymer batches.
Future Trends and Applications
- Integration of multi-detector systems (e.g., light scattering, viscometry) to directly measure absolute molecular weights and polymer architecture.
- Development of eco-friendly mobile phases and temperature-controlled GPC for enhanced green analytical practices.
- Expansion to copolymer and block polymer analysis, leveraging advanced data processing algorithms.
- Automation of sample handling to increase throughput in high-volume QA/QC laboratories.
Conclusion
This application note outlines a validated GPC method for comprehensive characterization of PEO/PEG using PSS SUPREMA columns. Optimized mobile phase conditions, column selections, and sample preparation guidelines enable reliable determination of molar mass distributions from oligomers to ultra-high-molecular-weight polymers. The method supports diverse analytical needs in research, quality control, and process development.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Characterization of Poly(ethylene glycol) II
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10297 - Column Application Note Characterization of Poly(ethylene…
Key words
pss, psssuprema, supremapoly, polyethylene, ethyleneglycol, glycolfax, faxmail, mailphone, phonepeg, pegweb, webdocument, documentpolymer, polymerreadycal, readycalrepublished, republishederrata
Characterization of Poly(ethylene glycol) I
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10044 - Column Application Note Characterization of Poly(ethylene…
Key words
pss, psssdv, sdvpoly, polyethylene, ethyleneglycol, glycolfax, faxmail, mailphone, phoneweb, webdocument, documentpolymer, polymerreadycal, readycalelugram, elugramrepublished, republishederrata
Characterization of Poly(methacrylic acid)
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10033 - Column Application Note Characterization of Poly(methacrylic…
Key words
pss, psssuprema, supremamethacrylic, methacrylicfax, faxmail, mailphone, phonepoly, polyweb, webdocument, documentpolymer, polymerelugram, elugramrepublished, republishederrata, erratarecommandations, recommandationspdi
Characterization of Poly(acrylic acid)
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10052 - Column Application Note Characterization of Poly(acrylic…
Key words
pss, psssuprema, supremaacrylic, acrylicfax, faxmail, mailphone, phonepoly, polyweb, webdocument, documentpolymer, polymerelugram, elugramrepublished, republishederrata, erratarecommandations, recommandationspdi