Agilent ZORBAX Rapid Resolution High Definition Eclipse XDB-C18 Column
Brochures and specifications | 2010 | Agilent TechnologiesInstrumentation
The development of high pressure, high efficiency reversed phase columns is critical for modern UHPLC applications involving complex samples. Enhanced surface chemistry and mechanical stability directly impact the reproducibility and speed of analyses of acidic, basic, and polar compounds.
This datasheet details the design principles, packing methodology, and performance evaluation of the Agilent ZORBAX RRHD Eclipse XDB-C18 column. The primary aims are to achieve ultra-high resolution, broad pH compatibility, and reliable operation at pressures up to 1200 bar.
The column uses a dense monolayer of dimethyl-n-octadecylsilane bonded to ultra-pure Type B silica (180 m2/g, 80 Å pores). A proprietary high-pressure slurry-loading technique and double endcapping procedure ensure maximum surface deactivation and column efficiency.
Quality control tests demonstrate exceptional plate counts and symmetric peak shapes for basic, acidic, and neutral analytes. The column operates safely up to 1200 bar and 60 °C, with optimal lifetime at 40 °C and pH 3–8. Double endcapping reduces deleterious sample–surface interactions and silica dissolution under intermediate to high pH.
Emerging developments will target further enhancement of pH resilience, refinement of core-shell and sub-2 µm particle technologies, and integration with high resolution mass spectrometry. Automation and miniaturization trends will expand the utility of UHPLC in pharmaceutical, environmental, and clinical laboratories.
The Agilent ZORBAX RRHD Eclipse XDB-C18 column combines advanced bonding and deactivation strategies to deliver robust performance at ultra-high pressures. Its versatility for acidic, neutral, and basic compounds makes it a valuable tool in diverse analytical settings.
Consumables, LC columns
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
The development of high pressure, high efficiency reversed phase columns is critical for modern UHPLC applications involving complex samples. Enhanced surface chemistry and mechanical stability directly impact the reproducibility and speed of analyses of acidic, basic, and polar compounds.
Objectives and Study Overview
This datasheet details the design principles, packing methodology, and performance evaluation of the Agilent ZORBAX RRHD Eclipse XDB-C18 column. The primary aims are to achieve ultra-high resolution, broad pH compatibility, and reliable operation at pressures up to 1200 bar.
Methodology and Instrumentation
The column uses a dense monolayer of dimethyl-n-octadecylsilane bonded to ultra-pure Type B silica (180 m2/g, 80 Å pores). A proprietary high-pressure slurry-loading technique and double endcapping procedure ensure maximum surface deactivation and column efficiency.
- Stationary phase: XDB-C18 on ZORBAX Rx-SIL Type B silica
- Packing: high-pressure slurry loading, eXtra-Dense Bonding, double endcapping
- QC conditions: 2.1 × 50 mm, 1.8 µm, 55/45 acetonitrile/water, 0.55 mL/min
Main Results and Discussion
Quality control tests demonstrate exceptional plate counts and symmetric peak shapes for basic, acidic, and neutral analytes. The column operates safely up to 1200 bar and 60 °C, with optimal lifetime at 40 °C and pH 3–8. Double endcapping reduces deleterious sample–surface interactions and silica dissolution under intermediate to high pH.
Benefits and Practical Applications
- Rapid, high resolution separations of a broad range of compounds
- Wide pH stability for flexible method development
- High mechanical strength for long-term UHPLC use
- Improved peak shape for basic analytes without mobile phase modifiers
Future Trends and Applications
Emerging developments will target further enhancement of pH resilience, refinement of core-shell and sub-2 µm particle technologies, and integration with high resolution mass spectrometry. Automation and miniaturization trends will expand the utility of UHPLC in pharmaceutical, environmental, and clinical laboratories.
Conclusion
The Agilent ZORBAX RRHD Eclipse XDB-C18 column combines advanced bonding and deactivation strategies to deliver robust performance at ultra-high pressures. Its versatility for acidic, neutral, and basic compounds makes it a valuable tool in diverse analytical settings.
Used Instrumentation
- Agilent ZORBAX RRHD Eclipse XDB-C18 column, 2.1 × 50 mm, 1.8 µm
- Agilent 1290 Infinity UHPLC system
References
- H.A. Claessens, M.A. van Straten, J.J. Kirkland, J. Chromatogr. A, 728 (1996) 259
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent ZORBAX Rapid Resolution High Definition Eclipse XDB-C18 Column - Data Sheet
2010|Agilent Technologies|Applications
Agilent ZORBAX Rapid Resolution High Definition Eclipse XDB-C18 Column Data Sheet General Description Agilent ZORBAX Rapid Resolution High Definition (RRHD) Eclipse XDB-C18 threaded columns are specially designed for use with ultra high performance liquid chromatographs (UHPLCs) such as the Agilent…
Key words
zorbax, zorbaxdense, denseagilent, agilentrrhd, rrhdcolumn, columnassembled, assembledcolumns, columnsbonded, bondedshould, shouldphase, phaseoctadecylsilane, octadecylsilaneuhplcs, uhplcsstationary, stationarymutually, mutuallymonolayer
Agilent ZORBAX Rapid Resolution High Definition SB-C18 Threaded Column
2009|Agilent Technologies|Brochures and specifications
Agilent ZORBAX Rapid Resolution High Definition SB-C18 Threaded Column Data Sheet etary, high-pressure, slurry-loading technique to give optimim column efficiency. General Description ZORBAX Rapid Resolution High Definition (RRHD) SB-C18 threaded columns are specially designed for use with ultra-high performance liquid…
Key words
column, columnrrhd, rrhdcolumns, columnszorbax, zorbaxagilent, agilentshould, shouldhigh, highuhplcs, uhplcsuse, useflammability, flammabilitythreaded, threadedenclosed, enclosedmechanically, mechanicallychromatographs, chromatographscapped
Agilent ZORBAX Rapid Resolution High Definition 300SB-C18 Threaded Column
2011|Agilent Technologies|Brochures and specifications
Agilent ZORBAX Rapid Resolution High Definition 300SB-C18 Threaded Column Data Sheet General Description ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C18 threaded columns are specially designed for use with ultra-high performance liquid chromatographs (UHPLCs) such as the Agilent 1290 Infinity LC…
Key words
column, columnthreaded, threadedrrhd, rrhdcolumns, columnszorbax, zorbaxagilent, agilentbonded, bondedphase, phaseoctadecylsilane, octadecylsilanehigh, highuhplcs, uhplcsuse, usestationary, stationarymutually, mutuallyresists
Agilent ZORBAX Rapid Resolution High Definition SB-C8 Threaded Column
2009|Agilent Technologies|Brochures and specifications
Agilent ZORBAX Rapid Resolution High Definition SB-C8 Threaded Column Data Sheet uniform bed density using a proprietary, high-pressure, slurryloading technique to give optimum column efficiency. General Description ZORBAX Rapid Resolution High Definition (RRHD) SB-C8 threaded columns are specially designed for…
Key words
rrhd, rrhdcolumn, columnstable, stablezorbax, zorbaxshould, shouldoctylsilane, octylsilanetemperatures, temperaturescolumns, columnsstationary, stationaryphases, phasesagilent, agilentflammability, flammabilityphase, phaseenclosed, encloseddiisopropyl