Applications and Use of High Pressure and Ultra High Pressure LC ColumnsLC Column
Posters | 2009 | Agilent Technologies | HPLC SymposiumInstrumentation
The use of high-pressure and ultra-high-pressure liquid chromatography (HPLC/UHPLC) with sub-2 µm particles has revolutionized analytical separations by delivering higher efficiency, faster run times and improved resolution. These advances are crucial for pharmaceutical quality control, environmental monitoring, metabolomics and proteomics, where speed and data quality directly impact decision-making and throughput.
This study aims to evaluate the robustness, efficiency and lifetime performance of Agilent ZORBAX RRHD columns operated at pressures up to 1200 bar. Key goals include:
Columns evaluated:
Chromatographic conditions:
Emerging directions include:
Agilent ZORBAX RRHD columns, when operated on a 1290 Infinity LC system at pressures up to 1200 bar, deliver robust performance, exceptional efficiency and long lifetimes. Selection of column length and coupling strategies enables precise control over resolution and analysis speed, meeting diverse analytical demands from rapid screening to in-depth separations.
Consumables, LC columns
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
The use of high-pressure and ultra-high-pressure liquid chromatography (HPLC/UHPLC) with sub-2 µm particles has revolutionized analytical separations by delivering higher efficiency, faster run times and improved resolution. These advances are crucial for pharmaceutical quality control, environmental monitoring, metabolomics and proteomics, where speed and data quality directly impact decision-making and throughput.
Objectives and Study Overview
This study aims to evaluate the robustness, efficiency and lifetime performance of Agilent ZORBAX RRHD columns operated at pressures up to 1200 bar. Key goals include:
- Comparing column lengths (50 mm, 100 mm, 150 mm) in terms of resolution and analysis time
- Assessing column lifetime through extended low- and high-pressure injection lifetests (650 bar and 950 bar)
- Demonstrating the benefit of coupling columns for enhanced resolution
- Showcasing sub-one-minute separations and fast analysis of derivatized compounds
Methodology and Instrumentation
Columns evaluated:
- ZORBAX RRHD SB-C18, 2.1 × 50 mm, 1.8 µm
- ZORBAX RRHD Eclipse Plus C18, 2.1 × 100 mm and 2.1 × 150 mm, 1.8 µm
Chromatographic conditions:
- Mobile phases: water/acetonitrile mixtures (40:60 or gradient 60–70 % ACN)
- Flow rates: 0.3–2.3 mL/min depending on column and application
- Temperatures: ambient or 60 °C for fast separations
- Pressure range: up to 1200 bar on Agilent 1290 Infinity LC system
Main Results and Discussion
- Low-pressure lifetest at 650 bar and high-pressure at 950 bar over 5000 injections showed negligible loss in plate count (from ~21 722 to ~20 653) and consistent retention behavior.
- Column length selection balances resolution (higher for 150 mm) and analysis time (shortest for 50 mm). Effective Rs values improved from 5.6 (50 mm) to 11.98 (150 mm) under UHPLC conditions.
- Coupling 100 mm and 150 mm RRHD columns delivered N6 ≈ 49 200 and Rs3,2 of ~4.9, demonstrating scalable resolution gains.
- Sub-one-minute separations of small molecules and six-compound biocide mixes were achieved using 2.1 × 50 mm columns at 2 mL/min and 975 bar.
- Analysis of DNPH-derivatized aldehydes on two coupled 100 mm columns reached initial pressures >1080 bar and provided clear separation of up to 13 compounds within 9 min.
Benefits and Practical Applications
- Higher sample throughput due to faster gradients and sub-minute separations.
- Improved resolution enables detection of closely eluting or low-abundance analytes.
- Extended column lifetime under ultra-high-pressure conditions supports sustainable lab operations.
- Flexible column coupling strategies allow method tailoring for targeted applications in pharmaceuticals, food safety and environmental testing.
Future Trends and Applications
Emerging directions include:
- Further expansion of pressure limits beyond 1200 bar for even higher efficiency with sub-1 µm particles.
- Integration of UHPLC with high-resolution mass spectrometry for proteomics and metabolomics.
- Development of novel stationary phases optimized for ultra-high-pressure stability and selectivity.
- Green chromatography approaches leveraging reduced solvent usage with narrower bore columns.
- High-throughput two-dimensional LC systems utilizing coupled columns under ultra-high pressure.
Conclusion
Agilent ZORBAX RRHD columns, when operated on a 1290 Infinity LC system at pressures up to 1200 bar, deliver robust performance, exceptional efficiency and long lifetimes. Selection of column length and coupling strategies enables precise control over resolution and analysis speed, meeting diverse analytical demands from rapid screening to in-depth separations.
Reference
- Link J, Brooks A, Henderson JW Jr, Long W, Martone N, Martosella J, Permar B. Applications and Use of High Pressure and Ultra High Pressure LC Columns. HPLC 2009, Agilent Technologies.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Lifetime Stability and Comparative Performance Analyses of Reversed-Phase Ultra High Performance Liquid Chromatography (UHPLC) Columns
2010|Agilent Technologies|Posters
Lifetime Stability and Comparative Performance Analyses of Reversed-Phase Ultra High Performance Liquid Chromatography (UHPLC) Columns 3000 RRHD Lifetime 200 >5,000 0 Injections 400 1000 0 0 High pressure 3000 4000 5000 25000 20000 run #1 (starting run) run#2 (1.5 hr…
Key words
bar, barpressure, pressureinjections, injectionsrrhd, rrhdefficiency, efficiencylifetest, lifetestuhplc, uhplcmicroparticulates, microparticulatesstability, stabilitylifetime, lifetimecolumn, columnbed, bedplasma, plasmaperformance, performancehigh
Increasing Resolution and Speed by Operating UHPLC Columns up to 1200 Bar
2009|Agilent Technologies|Technical notes
Increasing Resolution and Speed by Operating UHPLC Columns up to 1200 Bar Technical Note ZORBAX RRHD SB-C18, 2.1 x 100 mm, 1.8 μm Maximum pressure = 595 bar nc = 485 mAU Rs: 1.37 200 150 100 50 0 0…
Key words
mau, maucolumns, columnsresolution, resolutionmin, minzorbax, zorbaxspeed, speedrrhd, rrhdagilent, agilentndga, ndgathbp, thbppower, powerrate, ratehigh, hightbhq, tbhqalkylphenones
Agilent ZORBAX Rapid Resolution High Definition (RRHD) Columns
2016|Agilent Technologies|Brochures and specifications
Available in more than TWELVE bonded phases and in 300Å configurations Achieve true high-definition separations without sacrificing stability Agilent ZORBAX Rapid Resolution High Definition (RRHD) Columns ZORBAX RRHD columns take your fast and high-resolution separations to the next level with:…
Key words
stablebond, stablebondzorbax, zorbaxrrhd, rrhdeclipse, eclipsephenyl, phenylplus, plusaea, aeaoea, oeaseparations, separationspea, peadiphenyl, diphenylpeptide, peptidedouble, doublechain, chainmin
Agilent ZORBAX Rapid Resolution High Definition (RRHD) Columns
2013|Agilent Technologies|Brochures and specifications
Available in more than TWELVE bonded phases and in 300Å configurations Achieve true high-definition separations without sacrificing stability Agilent ZORBAX Rapid Resolution High Definition (RRHD) Columns ZORBAX RRHD columns take your fast and high-resolution separations to the next level with:…
Key words
stablebond, stablebondzorbax, zorbaxrrhd, rrhdeclipse, eclipsephenyl, phenylplus, plusaea, aeaoea, oeaseparations, separationspea, peadiphenyl, diphenylpeptide, peptidedouble, doublechain, chainmin