LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Agilent 1100 Series HPLC Value System - User’s Guide

Manuals | 1999 | Agilent TechnologiesInstrumentation
HPLC
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


The Agilent 1100 Series HPLC Value System represents a versatile, cost-effective platform for high-performance liquid chromatography in research, quality control, and industrial laboratories. By integrating modular hardware with user-friendly software, this system streamlines routine analyses, enhances reproducibility, and supports rapid troubleshooting—all critical factors for reliable compound separation, quantification, and method development.

Objectives and Overview


This User’s Guide is designed to help analysts and laboratory personnel with:
  • Understanding key system features, specifications, and operational limits.
  • Performing proper installation and initial configuration of HPLC modules.
  • Setting up an isocratic analysis with standard compounds.
  • Utilizing diagnostic tools for performance verification and fault isolation.
  • Carrying out routine maintenance, firmware updates, and system recovery.

Methodology and Instrumentation


The Agilent 1100 Value System employs a modular architecture, interconnected via Controller Area Network (CAN) and managed over a LAN link using a JetDirect card. Core modules include:
  • G1310A Isocratic Pump with solvent cabinet and purge valve.
  • G1328A Manual Injector featuring a six-port rotary valve and sample loop.
  • G1314A Variable Wavelength Detector (VWD) equipped with a 10 mm path-length flow cell.
  • 2D-Value Solution ChemStation software running on Windows NT, controlling modules via TCP/IP.

Optional components such as the thermostatted column compartment, fluorescence detector, and refractive index detector may be added to extend functionality. The guide details solvent priming, capillary connections, software setup, and method parameter transfer.

Main Features and Discussion


• System Configuration and Restrictions: Defines permissible module combinations and operating modes under the Value Solution license.
• Site Requirements: Bench space, power specifications (100–120 or 220–240 VAC), environmental tolerances (0–55 °C, non-condensing humidity), and safety considerations.
• Performance Specifications: Physical dimensions, weight, power consumption, and compliance with safety and EMC standards.
• Installation Workflow: Step-by-step instructions for module stacking, LAN setup with Bootp Server, and ChemStation configuration editor.
• Method Setup: Example isocratic analysis of a dimethylphthalate/diethylphthalate/biphenyl/o-terphenyl standard, including flow rate, wavelength, and injection procedure.
• Diagnostic Tools: LED status indicators, analog output signals, online error and status logs, module-specific tests, and troubleshooting guides.
• Maintenance Procedures: Firmware updates via Agilent support portal, deinstallation/reinstallation of software, and full system recovery after OS failure.

Benefits and Practical Applications


  • Modularity simplifies upgrades and expands analytical capabilities on demand.
  • Network-based control allows remote operation and seamless data integration.
  • Comprehensive diagnostics reduce downtime by isolating leaks, lamp faults, and communication errors.
  • Standardized workflows and method templates accelerate routine analyses in pharmaceutical, environmental, and food testing laboratories.

Instrumentation Used


  • Agilent 1100 Series modules: G1310A, G1314A, G1328A, JetDirect LAN card.
  • Optional modules: G1316A column compartment, G1321A FLD, G1362A RID, G1323B control module.
  • Value Solution ChemStation software on Windows NT PC.

Future Trends and Potential Applications


Emerging developments in HPLC instrumentation and software promise:
  • Cloud-enabled data management and collaborative method sharing.
  • Enhanced automation with online sample preparation and autosamplers.
  • Advanced detector technologies (e.g., multi-wavelength photodiode arrays, mass spectrometry interfaces) for greater selectivity.
  • Integration of artificial intelligence tools for predictive maintenance and method optimization.

Conclusion


The Agilent 1100 Series HPLC Value System delivers a balanced combination of performance, reliability, and cost efficiency. Its modular design, robust diagnostics, and comprehensive software support enable laboratories to maintain high throughput and data quality while minimizing operational complexity.

References


None specified in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity Control Module AGILENT ICF FOR LC
Clarity Control Module AGILENT ICF FOR LC
2024|Agilent Technologies|Manuals
AGILENT ICF FOR LC Clarity Control Module ENG Code/Rev.: M155/80M Date: 11/1/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows…
Key words
icf, icfagilent, agilentclarity, claritydialog, dialogsetup, setupconfiguration, configurationaddress, addressconfigured, configuredhostname, hostnamedevice, devicetab, tablan, lanyou, youconfigure, configuredisplayed
Clarity Control Module AGILENT 1100/1200
Clarity Control Module AGILENT 1100/1200
2024|Agilent Technologies|Manuals
AGILENT 1100/1200 Clarity Control Module ENG Code/Rev.: M060/80D Date: 11/1/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
device, deviceclarity, claritylamp, lampdialog, dialogserial, serialmonitor, monitorset, setgpib, gpibbutton, buttonwavelength, wavelengthwindow, windowlan, lanzero, zerostate, stateautozero
Agilent GC/LC ChemStation - Troubleshooting TCP/IP LAN Communication Issues
Troubleshooting TCP/IP LAN Communication Issues GC/LC ChemStation Contents 1. Introduction ............................ 3 2. General Information ..................... 3 3. Connectivity Issues ..................... 4 General test procedure.......................4 If the PING 'Request Timed Out' when pinging the instrument, try the following: .......6 Possible…
Key words
tcp, tcplan, lannetwork, networkchemstation, chemstationcommunication, communicationtroubleshooting, troubleshootingping, pingnic, nicissues, issueswindows, windowscommunications, communicationsinstrument, instrumentpinging, pingingbindings, bindingsconnection
GC/LC ChemStation - Troubleshooting TCP/IP LAN Communication Issues
Troubleshooting TCP/IP LAN Communication Issues GC/LC ChemStation Contents 1. Introduction ............................ 3 2. General Information ..................... 3 3. Connectivity Issues ..................... 4 General test procedure.......................4 If the PING 'Request Timed Out' when pinging the instrument, try the following: .......6 Possible…
Key words
tcp, tcplan, lannetwork, networkchemstation, chemstationcommunication, communicationtroubleshooting, troubleshootingping, pingnic, nicissues, issueswindows, windowscommunications, communicationsinstrument, instrumentpinging, pingingbindings, bindingsconnection
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike