CRM Europium (Eu) - Aqueous calibration solution ASTASOL® AN90181N
Others | 2023 | ANALYTIKAInstrumentation
Certified reference materials (CRMs) are essential for ensuring accuracy, reliability and traceability in quantitative analysis across various spectrometric and electroanalytical techniques.
This document summarises the certification details of ASTASOL® AN90181N, an aqueous calibration solution of europium at a nominal concentration of 1000 mg/L. The CRM is designed for calibration, validation and quality control in methods such as AAS, AES, ICP-OES, ICP-MS, molecular absorption and electrochemical analysis.
The europium solution was prepared gravimetrically from high-purity Eu2O3 (99.996%) and acidified with ultrapure HNO3 to achieve SI traceability. The certified concentration and its expanded uncertainty (k=2) were verified by complexometric titration against SRM NIST 928. Homogeneity and stability studies ensured consistency over the shelf life.
The CRM has a certified europium concentration of 1000 ± 2 mg/L (980 ± 3 mg/kg derived from density) at 20 °C. Density was determined as 1.0201 ± 0.0005 g/cm3. Trace impurities of over 60 elements were quantified by AAS, ICP-OES and ICP-MS, with all values below detection limits or at sub-ppm levels, confirming the high purity of the solution. Stability tests demonstrated consistent performance under proper storage conditions (5–30 °C) throughout the 5-year shelf life.
Ongoing developments in CRM technology may include multi-element solutions, enhanced matrix complexity, digital certification and integration with automated laboratories and software for real-time traceability and data management.
ASTASOL® AN90181N offers a high-purity, SI-traceable europium calibration standard with well-defined uncertainty, proven homogeneity and stability. Its robust certification supports a wide range of analytical methods, enhancing reliability and quality assurance in routine and advanced laboratory applications.
Standards and chemicals
IndustriesManufacturerANALYTIKA
Summary
Significance of the topic
Certified reference materials (CRMs) are essential for ensuring accuracy, reliability and traceability in quantitative analysis across various spectrometric and electroanalytical techniques.
Objectives and overview
This document summarises the certification details of ASTASOL® AN90181N, an aqueous calibration solution of europium at a nominal concentration of 1000 mg/L. The CRM is designed for calibration, validation and quality control in methods such as AAS, AES, ICP-OES, ICP-MS, molecular absorption and electrochemical analysis.
Methodology and instrumentation
The europium solution was prepared gravimetrically from high-purity Eu2O3 (99.996%) and acidified with ultrapure HNO3 to achieve SI traceability. The certified concentration and its expanded uncertainty (k=2) were verified by complexometric titration against SRM NIST 928. Homogeneity and stability studies ensured consistency over the shelf life.
Instrumental techniques used
- Gravimetric preparation with sub-boiled distilled HNO3
- Complexometric titration (traceability to NIST SRM 928)
- Atomic absorption spectrometry (AAS)
- ICP optical emission spectrometry (ICP-OES)
- ICP mass spectrometry (ICP-MS)
Key results and discussion
The CRM has a certified europium concentration of 1000 ± 2 mg/L (980 ± 3 mg/kg derived from density) at 20 °C. Density was determined as 1.0201 ± 0.0005 g/cm3. Trace impurities of over 60 elements were quantified by AAS, ICP-OES and ICP-MS, with all values below detection limits or at sub-ppm levels, confirming the high purity of the solution. Stability tests demonstrated consistent performance under proper storage conditions (5–30 °C) throughout the 5-year shelf life.
Benefits and practical applications
- Provides SI-traceable calibration for spectrometric and electroanalytical techniques
- Improves accuracy and comparability of analytical results
- Supports method validation and routine quality control in laboratories
Future trends and applications
Ongoing developments in CRM technology may include multi-element solutions, enhanced matrix complexity, digital certification and integration with automated laboratories and software for real-time traceability and data management.
Conclusion
ASTASOL® AN90181N offers a high-purity, SI-traceable europium calibration standard with well-defined uncertainty, proven homogeneity and stability. Its robust certification supports a wide range of analytical methods, enhancing reliability and quality assurance in routine and advanced laboratory applications.
References
- ISO Guide 31: Preparation of Reference Materials – Contents of Certificates and Labels
- NIST SRM 928: Europium Standard for Complexometric Titration
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
CRM Yttrium (Y) - Aqueous calibration solution ASTASOL® AN90671N
2023|ANALYTIKA|Others
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouscalibration, calibrationyttrium, yttriumbellow, bellowastasol, astasolreference, referencedeclared, declaredexpiration, expirationanalysing, analysingsolutions, solutionsstoring, storinghomogeneous, homogeneousshelf, shelfguarantees
CRM Indium (In) - Aqueous calibration solution ASTASOL® AN90261N
2022|ANALYTIKA|Others
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouscalibration, calibrationindium, indiumbellow, bellowastasol, astasoldeclared, declaredreference, referenceexpiration, expirationanalysing, analysingsolutions, solutionsstoring, storinghomogeneous, homogeneousshelf, shelfguarantees
CRM Lanthanum (La) - Aqueous calibration solution ASTASOL® AN90291N
2022|ANALYTIKA|Others
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouslanthanum, lanthanumcalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredreference, referenceexpiration, expirationanalysing, analysingsolutions, solutionsstoring, storinghomogeneous, homogeneousshelf, shelfguarantees
CRM Terbium (Tb) - Aqueous calibration solution ASTASOL® AN90581N
2021|ANALYTIKA|Others
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueousterbium, terbiumcalibration, calibrationbellow, bellowastasol, astasolreference, referencedeclared, declaredexpiration, expirationanalysing, analysingsolutions, solutionsstoring, storinghomogeneous, homogeneousshelf, shelfguarantees